ALL ABOUT HOME DESIGN, LLC | B= | C | 09/04/2019 | All other required Final inspections are complete. (This is a computer generated result) | NATHAN | NATHAN | | B= | C | 6323171 |
ALL ABOUT HOME DESIGN, LLC | B= | P | 08/22/2019 | finished basement, a/c installed. Additional Inspections Required (computer generated): External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NATHAN | NATHAN | | B= | P | 6311512 |
ALL ABOUT HOME DESIGN, LLC | BLA | C | 02/28/2019 | flashing installed | NATHAN | NATHAN | | BLA | C | 6120796 |
ALL ABOUT HOME DESIGN, LLC | BLA | P | 02/12/2019 | Need to install flashing over front door trim / All other lath OK | NICK | NICK | | BLA | P | 6105334 |
ALL ABOUT HOME DESIGN, LLC | BIN | C | 01/17/2019 | | NATHAN | NATHAN | | BIN | C | 6082088 |
ALL ABOUT HOME DESIGN, LLC | BFR | C | 01/11/2019 | items corrected, letter for truss fix picked up, repair okay, crawlspace framing okay | NATHAN | NATHAN | | BFR | C | 6076544 |
ALL ABOUT HOME DESIGN, LLC | BFN | C | 01/11/2019 | stamped micro pier observation letter on file dated 5-08-18 | NATHAN | NATHAN | | BFN | C | 6075544 |
ALL ABOUT HOME DESIGN, LLC | BFR | R | 12/21/2018 | need drilled pier stamped observation, need garage portal frame completed all covered, need lateral bracing at B3,B4,B5, need truss clips at garage B5 trusses garage storage wall, D1 truss missing second lateral at rear lower slope, need truss laterals at H2-H4, west G2 girder missing nails at HGUS28 hangers and HUS28, HF to H5 girder at east and west side missing nails in HGUS28, missing gusset at HF girder on SE end, dry in roof penetrations, need steel shims at east stair beam, need inspection of crawlspace at reframe. | NATHAN | NATHAN | | BFR | R | 6061577 |
ALL ABOUT HOME DESIGN, LLC | BTR | P | 12/05/2018 | upper roof and deck membrane rear patio battens not installed | NATHAN | NATHAN | | BTR | P | 6043866 |
ALL ABOUT HOME DESIGN, LLC | BFD | P | 06/21/2018 | need tie in to drain and daylight at north west corner | NATHAN | NATHAN | | BFD | P | 5882014 |
ALL ABOUT HOME DESIGN, LLC | BFT | P | 06/21/2018 | drilled pier observation needed. | NATHAN | NATHAN | | BFT | P | 5881054 |
ALL ABOUT HOME DESIGN, LLC | BFN | P | 06/21/2018 | Drilled pier observation needed, foundation observation, ufer, openex, foundation print and soils on file. | NATHAN | NATHAN | | BFN | P | 5881051 |
ALL ABOUT HOME DESIGN, LLC | BFD | P | 04/26/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5828900 |
ALL ABOUT HOME DESIGN, LLC | BFT | P | 04/26/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5828899 |
ALL ABOUT HOME DESIGN, LLC | BFN | P | 04/26/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5828898 |
ROWAN ELECTRIC LLC | E= | C | 08/16/2019 | corrections made / | MIGUEL | MIGUEL | | E= | C | 6303792 |
ROWAN ELECTRIC LLC | E= | R | 08/15/2019 | garage attic incomplete / GFCI in garage closet on bath circuit / rest of house ok / 50A A/C / 25A A/C / 30A exterior heaters x2 / blanked lighting box above master tub / basement sub panels / | MIGUEL | MIGUEL | | E= | R | 6303026 |
ROWAN ELECTRIC LLC | ESP | C | 08/05/2019 | went over counter outlet spacing around the sink | MATTHEW | MATTHEW | | ESP | C | 6287607 |
ROWAN ELECTRIC LLC | ES | C | 02/04/2019 | Residential Underground: 400 amp 3/w new res | TIMA | TIMA | | ES | C | 6096515 |
ROWAN ELECTRIC LLC | ES | R | 01/31/2019 | need to land gec to the neutral bar in new disconnect or install wire jumper from neutral to ground bar--- Pics ok, upload images with next inspection request. If you encounter problems uploading images, please contact IT at 799-2688 / ----------400 amp 3/w | BRIAN | BRIAN | | ES | R | 6093634 |
ROWAN ELECTRIC LLC | ES | P | 11/29/2018 | Residential Underground: 200A 3w new res ok to set meter-----meter housing 320A / ------------- inspection results changed to partial by Matt ; service changed to 300 amp or 400 amp -------- | MIGUEL | MIGUEL | | ES | P | 6038110 |
ROWAN ELECTRIC LLC | ER | C | 11/29/2018 | IR ufer connections x2---6/3 AL x3, 2-A/C, 1-dbl oven---finished basement w/ sub panels--no central vac, crawler, no equipment---exterior heat ran w/ #10 nm cable---outlets throughout house will be cut into baseboard--floor heat in master bath / | MIGUEL | MIGUEL | | ER | C | 6038106 |
CUSTOM CLIMATE CONTROL | H= | C | 08/21/2019 | PLAN SPLICE UNDER PLAN IMAGE | MATTM | MATTM | | H= | C | 6309040 |
CUSTOM CLIMATE CONTROL | H= | P | 08/21/2019 | ALL DECORATIVE SHROUDS HAVE BEEN REMOVED, COMPLETION PENDING APPROVAL OF NEW PLANS REFLECTING INSTALLATION OF 80% FURNACE IN ATTIC. | MATTM | MATTM | | H= | P | 6308627 |
CUSTOM CLIMATE CONTROL | H= | P | 08/15/2019 | *****UPDATE 8/15/19 BY MLM----WILL NEED NEW HEAT CALCS FOR NEW 80% FURNACE NOT LISTED ON DUCT DESIGN, WILL NEED INSTALLATION INSTRUCTIONS FOR B-VENT RUBBER BOOT ON STANDING SEAM TIN ROOF, RUBBER BOOT NEEDS TO BE RATED FOR 400 DEGREES FAHRENHEIT***** FURTHER RESEARCH IS REQUIRED FOR UNIT HEATER B-VENT ROOF JACK, PROVIDE INSTALLATION INSTRUCTIONS FOR DECORATIVE SHROUD, DECORATIVE SHROUDS MUST BE LISTED PER 2009 IFGC SECTION 503.6.4.1, OUTSIDE AIR DUCTS IN BASEMENT MISSING AUTOMATIC OR BACKDRAFT DAMPERS PER 20015 IECC SECTION 403.5, BOTH 90% FURNACES IN BASEMENT MISSING VENT TEE ON CONDENSATE DRAIN PER MANUFACTURES INSTALLATION INSTRUCTIONS PAGE 67 AND 68. OK TO ATTACH PICTURES TO NEXT INSPECTION REQUEST. NOTES: FINISHED BASEMENT, VENTILATED ATTIC, 3X OUTSIDE AIR TO FURNACE RETURN, 2X DIRECT VENT FURNACE, DIRECT VENT WATER HEATER, 2X A/C INSTALLED | MATTM | MATTM | | H= | P | 6302294 |
CUSTOM CLIMATE CONTROL | H= | P | 08/14/2019 | RECEIVED CHANGE OF EQUIPMENT LETTER AND DUCT LEAKAGE REPORT FROM CONTRACTOR, SEE IMAGES. | MATTM | MATTM | | H= | P | 6299500 |
SPRINGS GAS, INC. | HSP | P | 11/27/2018 | SEE HI NOTES FOR FINAL INSPECTION. | PAULO | PAULO | | HSP | P | 6035144 |
CUSTOM CLIMATE CONTROL | HC | C | 11/27/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 6035143 |
CUSTOM CLIMATE CONTROL | HRR | C | 11/27/2018 | NEEDED BY FINAL-- NEW HEAT CALCS FOR UPPER LEVEL FURNACE (CHANGED EFFICIENCY FROM 90% TO 80%), DUCT LEAKAGE REPORT. note: conditioned crawl space, partial finished basement, outside air to all 3 furnace returns, 2- direct vent furnaces to main and basement levels, direct vent water heater, a/c rough and line set to (F2) furnace on the right, a/c rough and line to upper level, 600 CFM'S to range hood. | PAULO | PAULO | | HRR | C | 6035098 |
CUSTOM CLIMATE CONTROL | HRR | P | 11/16/2018 | STOPPED INSPECTION, NO ARTIFICIAL LIGHT IN BASEMENT, UNABLE TO INSPECT, ONLY INSPECTED MAIN AND UPPER LEVEL, RECALL INSPECTION, UPPER LEVEL FURNACE AND COIL INSTALLED DOES NOT MATCH EQUIPMENT LISTED ON APPROVED DUCT DESIGN. CONTRACTOR MUST FILL OUT THE EQUIPMENT CHANGE FORM (RESIDENTIAL) AND ATTACH FORM TO AN INSPECTION REQUEST BY FINAL. FORM CAN BE FOUND ON THE PPRBD WEBSITE UNDER DOWNLOADS, RESIDENTIAL HANDOUTS, EQUIPMENT CHANGE RESIDENTIAL DUCT DESIGN. SEAL ALL RETURN PENETRATIONS ON MAIN LEVEL, PROVIDE DUCT LEAKAGE REPORT FOR UPPER LEVEL SYSTEM, SUPPORT UPPER AND MAIN LEVEL DRYER DUCT EVERY 4FT, GARAGE UNIT HEAT VENT NEEDS TO BE CAPPED IN AN APPORVED MANNER, WHAT IS THE CFM OF THE RANGE HOOD TO BE INSTALLED IN THE KITCHEN? REPLACE WATER LOGGED EXHAUST DUCT IN UPPER LEVEL JACK AND JILL BATHROOM, INSTALL UPPER LEVEL OUTSIDE AIR TO FURNACE RETURN PER PRINT, GREAT ROOM FIREPLACE VENT NEEDS TO BE SUPPORTED EVERY 8FT PER PAGE 26 FIGURE 21, NOTES: UPPER LEVEL AC ROUGH COIL AND LINESET | MATTM | MATTM | | HRR | P | 6028810 |
SPRINGS GAS, INC. | HI | C | 11/15/2018 | BY FINAL NEED LETTER OF APPROVAL FOR 2 POUND SYSTEM , NEED TO SEE REGULATOR BY FINAL 10 LB TEST OK , 1 INCH MAIN (2 POUND SYSTEM) 3 FURNACES , 1 WATER HEATER , 3 FIRE PLACES , 1 RANGE , 1 GARAGE HEATER , 1 BBQ | ANDREWP | ANDREWP | | HI | C | 6026314 |
JOLLY PLUMBING & HEATING INC. | P= | C | 08/13/2019 | corrections made | JOSEPHD | JOSEPHD | | P= | C | 6298906 |
JOLLY PLUMBING & HEATING INC. | P= | P | 08/09/2019 | need hammer arrestors at dishwashers, dishwasher stand pipes need to be min 18", need to set sink in garage, need to run water heater pan drain, need to verify backflow at master tub and shower hand sprays, LH master shower valve crossed, missing aav @ lavs in upstairs jack and jill bathroom, rest ok note: partial finished basement, RP in mech | JOSEPHD | JOSEPHD | | P= | P | 6294999 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 12/19/2018 | crawl space (w/ no floor drains), vtr (2), running trap @ garage sink, aav @ all lavs / sinks (kitchen x3) and mech (minus garage sink and main level pwdr), aav @ main level w.b. @ left side in aav box, aav @ upr w.b. @ left wall corner in aav box, tempering @ right mstr, finished bsmnt, irrigation stub, rp @ mech for irrigation stub | JOHNS | JOHNS | | PTO | C | 6057525 |
JOLLY PLUMBING & HEATING INC. | PB | C | 06/29/2018 | | JOHNS | JOHNS | | PB | C | 5890075 |
ALL ABOUT HOME DESIGN, LLC | XMS | T | 08/21/2019 | PAID (REC#1624023) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised manuals for 80% furnace on system 3 | JUSTINC | JUSTINC | | XMS | T | 6308348 |
ALL ABOUT HOME DESIGN, LLC | XMS | T | 08/14/2018 | PAID (REC#1561047) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised duct design and calculations for field driven revisions | JUSTINC | JUSTINC | | XMS | T | 5933161 |
ALL ABOUT HOME DESIGN, LLC | XBS | T | 08/14/2018 | PAID (REC#1561047) PLAN SPLICE FEE: $50 by: DANM for Construction: Various structural revisions/clarifications | DANM | DANM | | XBS | T | 5932896 |
ALL ABOUT HOME DESIGN, LLC | XMS | T | 06/26/2018 | PAID (REC#1515232) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised heatloss calculations and duct designs | JUSTINC | JUSTINC | | XMS | T | 5885884 |
ALL ABOUT HOME DESIGN, LLC | XBS | T | 06/25/2018 | PAID (REC#1515232) PLAN SPLICE FEE: $50 by: DANM for Construction: Various revisions made throughout the plan, including removal of deck, addition of safety vault, covered rear porch, etc. | DANM | DANM | | XBS | T | 5884497 |