INNOVATIVE CONSTRUCTION, INC. | B= | C | 11/01/2018 | | DALE | DALE | | B= | C | 6013749 |
INNOVATIVE CONSTRUCTION, INC. | BFR | C | 11/01/2018 | pic on file for shim and post -- Schedule a new Building Final when above items are complete. | DALE | DALE | | BFR | C | 6012429 |
INNOVATIVE CONSTRUCTION, INC. | BIN | P | 08/13/2018 | complete bfr / insulate behind fireplace | DALE | DALE | | BIN | P | 5932680 |
INNOVATIVE CONSTRUCTION, INC. | BFR | P | 08/09/2018 | complete BSP for post / need steel shims under beam at crawl space / ok to insulate | DALE | DALE | | BFR | P | 5929767 |
INNOVATIVE CONSTRUCTION, INC. | BSP | P | 07/12/2018 | porch lid and deck frame ok / 1 post at north side halfway on pier | DALE | DALE | | BSP | P | 5901341 |
INNOVATIVE CONSTRUCTION, INC. | BSP | P | 07/12/2018 | eng. on file for deck posts | DALE | DALE | | BSP | P | 5900111 |
INNOVATIVE CONSTRUCTION, INC. | BFN | C | 05/17/2018 | foundation design on file | DALE | DALE | | BFN | C | 5847416 |
INNOVATIVE CONSTRUCTION, INC. | BFD | C | 05/17/2018 | drain daylighted | DALE | DALE | | BFD | C | 5847404 |
INNOVATIVE CONSTRUCTION, INC. | BFN | P | 05/16/2018 | Engineers observation Letter on file / need foundation design | DALE | DALE | | BFN | P | 5846139 |
INNOVATIVE CONSTRUCTION, INC. | BFT | C | 05/16/2018 | open hole on file / 3000 psf / 10% grade / 10% grade / Engineers observation Letter on file / | DALE | DALE | | BFT | C | 5846135 |
DUKES ELECTRIC, INC | E= | C | 10/22/2018 | | TOMC | TOMC | | E= | C | 6001473 |
DUKES ELECTRIC, INC | EP | C | 08/07/2018 | need retainer on 40 amp back fed breaker | TOMC | TOMC | | EP | C | 5926145 |
DUKES ELECTRIC, INC | ER | C | 08/07/2018 | need retainer on back fed breaker in panel | TOMC | TOMC | | ER | C | 5926131 |
DUKES ELECTRIC, INC | EUG | C | 07/12/2018 | 4/w #4 al #6 al grd from house to studio ok | CRAIG | CRAIG | | EUG | C | 5900620 |
EAGLE HEATING AND AIR CONDITIONING, INC. | H= | C | 10/30/2018 | | BILLS | BILLS | | H= | C | 6009662 |
WESTERN FIREPLACE SUPPLY, INC. | H= | C | 10/26/2018 | FIREPLACE CONTRACTOR COMPLETE. | DUSTINS | DUSTINS | | H= | C | 6006839 |
EAGLE HEATING AND AIR CONDITIONING, INC. | H= | P | 10/22/2018 | NEED TRAP LOOP INSTALLED AT WATER HEATER VENT CONDENSATE DRAIN, NEED TO WEATHER SEAL FURNACE VENTS AT EXTERIOR. OK TO ATTACH PICTURES AT NEXT INSPECTION REQUEST. NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, NO A/C, OUTSIDE AIR TO RETURN DUCT, LOUVER DOOR AT WATER HEATER CLOSET | BILLS | BILLS | | H= | P | 6001634 |
WESTERN FIREPLACE SUPPLY, INC. | H= | R | 10/18/2018 | Still need 12'' clearance from furnace vent discharge to grade. Water heater vent still not installed to manufacturers specs (see page 16). | JEFFL | JEFFL | | H= | R | 5998645 |
EAGLE HEATING AND AIR CONDITIONING, INC. | H= | P | 10/16/2018 | FURNACE VENT TERMINATION TO BE A MINIMUM OF 12" ABOVE GRADE, PROPERLY SUPPORT FURNACE AND SUPPLY AIR PLENUM, WATER HEATER VENT DOES NOT MEET THE MINIMUM LENGTH REQUIRED,THE BAY VENT TERMINATION IS NOT AN APPROVED TERMINATION FOR THIS WATER HEATER, NEEDS CONDENSATION DRAIN TUBE INSTALLED, AND NEED THE VENT RESTRICTION MESH INSTALLED. NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, NO A/C, OUTSIDE AIR TO RETURN DUCT, LOUVER DOOR AT WATER HEATER CLOSET | BILLS | BILLS | | H= | P | 5996080 |
EAGLE HEATING AND AIR CONDITIONING, INC. | HRR | C | 10/16/2018 | PICTURE OF BATH EXHAUST ATTACHED. CHECK WATER HEATER VENT AT FINAL. NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, OUTSIDE AIR TO FURNACE RETURN. | DUSTINS | DUSTINS | | HRR | C | 5995389 |
EAGLE HEATING AND AIR CONDITIONING, INC. | HRR | P | 08/14/2018 | NEED TO CONSULT WITH SENIOR INSPECTOR, WILL UPDATE IN THE MORNING. STILL UNABLE TO VERIFY BATH EXHAUST DUE TO INSULATION IN CEILING. NOTE: OUTSIDE AIR TO FURNACE RETURN, DIRECT VENT FURNACE, CONDITIONED CRAWLSPACE. | DUSTINS | DUSTINS | | HRR | P | 5933756 |
EAGLE HEATING AND AIR CONDITIONING, INC. | HRR | P | 08/13/2018 | Water heater vent not complete. Unable to see bath exhaust and fireplace vent due to insulation. Re inspect all. | JEFFL | JEFFL | | HRR | P | 5932237 |
O.M.A.G.M., INC. | H= | C | 08/08/2018 | FINAL FOR GAS CONTRACTOR ONLY | BILLS | BILLS | | H= | C | 5927528 |
O.M.A.G.M., INC. | H= | P | 08/06/2018 | NEED TO SEE REGULATOR AND MEDIUM PRESSURE LABELING IN PLACE FOR FINAL | BILLS | BILLS | | H= | P | 5925115 |
O.M.A.G.M., INC. | HI | C | 08/06/2018 | 10LB TEST OK. 3/4" MAIN, 1 FURNACE, 1 WATER HEATER, 1 FIREPLACE. | BILLS | BILLS | | HI | C | 5925114 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 08/02/2018 | vent and framing ok. | KYLEW | KYLEW | | HV | C | 5922026 |
O.M.A.G.M., INC. | HO | C | 07/12/2018 | 10LB TEST OK. 60' OF 1" POLY PIPE FROM METER TO NEW STRUCTURE | BILLS | BILLS | | HO | C | 5900544 |
CLARK PLUMBING & HEATING | P= | C | 10/05/2018 | | JOSEPHD | JOSEPHD | | P= | C | 5987559 |
CLARK PLUMBING & HEATING | PTO | C | 08/07/2018 | note: at final need to see connection to main at water heater, aav @ lav, and K.C, trap in crawlspace, floor drain in utility room vtr, | JOSEPHD | JOSEPHD | | PTO | C | 5926240 |
CLARK PLUMBING & HEATING | PWO | C | 07/05/2018 | note: existing well | JOSEPHD | JOSEPHD | | PWO | C | 5894062 |