HOMEOWNER | B= | C | 02/15/2019 | slab on grade | DALE | DALE | | B= | C | 6108562 |
HOMEOWNER | B= | R | 02/12/2019 | need landing at patio door / install house # on house / need air barrier at mech. room walls | DALE | DALE | | B= | R | 6105039 |
HOMEOWNER | BLA | C | 10/04/2018 | | DALE | DALE | | BLA | C | 5985716 |
HOMEOWNER | BIN | C | 10/02/2018 | | DALE | DALE | | BIN | C | 5983290 |
HOMEOWNER | BFR | C | 09/27/2018 | | DALE | DALE | | BFR | C | 5979029 |
HOMEOWNER | BFR | P | 09/25/2018 | Missing all lateral bracing on T01, and T01A trusses - Need fireblocking above main level fireplace - Float block at closet next to stairs - Tie upper fireplace walls to house walls - Upper SE bedroom, SE window needs (2) king studs ea side - T02G 3rd hanger from left missing side nail | TIMOTHYS | TIMOTHYS | | BFR | P | 5975723 |
HOMEOWNER | BFD | C | 09/25/2018 | BFT and BFN complete | TIMOTHYS | TIMOTHYS | | BFD | C | 5975714 |
HOMEOWNER | BSP | P | 09/13/2018 | Porch posts and lid ok | TIMOTHYS | TIMOTHYS | | BSP | P | 5964092 |
HOMEOWNER | BFN | C | 06/18/2018 | Received footing and foundation observations w/eufer / Open hole report 2,000 psf | SHAUN | SHAUN | | BFN | C | 5876917 |
HOMEOWNER | BFT | C | 06/18/2018 | Received footing and foundation observations w/eufer / Open hole report 2,000 psf | SHAUN | SHAUN | | BFT | C | 5876916 |
HOMEOWNER | BFD | P | 06/14/2018 | Complete BFT and BFN / Drain around habitable and entire / Gravity outfall to the south / Damp proofing okay | SHAUN | SHAUN | | BFD | P | 5874889 |
HOMEOWNER | BFN | P | 06/14/2018 | Provide open hole report / Soils report picked up on site 2,000 psf / Drain around habitable space / Float and Isolate / 10% grade / Foundation design 2,000 psf / Footing and foundation observation w/eufer / Detached garage under separate permit # L46679 | SHAUN | SHAUN | | BFN | P | 5874864 |
HOMEOWNER | BFT | P | 06/14/2018 | Provide open hole report / Soils report picked up on site 2,000 psf / Drain around habitable space / Float and Isolate / 10% grade / Foundation design 2,000 psf / Footing and foundation observation w/eufer / Detached garage under separate permit # L46679 | SHAUN | SHAUN | | BFT | P | 5874858 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | C | 01/24/2019 | | JOSEPH | JOSEPH | | E= | C | 6086970 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | R | 01/23/2019 | No power to septic system receptacle. Where is the reset for this receptacle? Is there an upstream GFCI recept? Remember Septic needs to be a dedicated circuit / Rest is good | JOSEPH | JOSEPH | | E= | R | 6085623 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | R | 01/17/2019 | Complete re-inspection required, Following is a partial list only. / Exterior outlets missing GFCI protection / Exhaust fan in shower stall needs GFCI protection. / Redo neutral termination for circuit # 14 so all strands are under the terminal. / Label panel directory completely / Tighten green ground screw in well disconnect / All receptacles below 5 - 1/2 feet need to be TR type / Dishwasher and laundry room need GFCI & AFCI protection / GFCI outlet for septic will not reset & this circuit should be dedicated. / At the septic system it's not ok to have the cord from the pump run on the outside without physical protection. / AFCI protection per 2014 NEC / Too much to list / Notes: 20 amp ac | JOSEPH | JOSEPH | | E= | R | 6081446 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ES | C | 01/17/2019 | Residential Underground: 200 amp 3w new res meter is in and sealed no action required. | JOSEPH | JOSEPH | | ES | C | 6081413 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | EUG | C | 11/08/2018 | PVC for septic | JOSEPH | JOSEPH | | EUG | C | 6019663 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ER | C | 09/18/2018 | Slab --------- No vac ------- 3 - 10/3 ---- 6/3 al ---- UFER is not ir | JOSEPH | JOSEPH | | ER | C | 5968245 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 01/14/2019 | NOTE: DIRECT VENT FURNACE, FULL A/C, OUTSIDE AIR WITH DAMPER TO RETURN DUCT( ACCESS IS A 12"/12" IN KITCHEN CEILING), ELECTRIC WATER HEATER | BILLS | BILLS | | H= | C | 6077031 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 01/14/2019 | FURNACE CHANGE LETTER RECEIVED, SEE IMAGES | BILLS | BILLS | | H= | P | 6076886 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 01/11/2019 | INSTALL CORRECT FURNACE, SECURE CONDENSATE DRAINS AND INSTALL DRAIN VENT, NEED PROPER VENT TERMINATIONS SEE PAGES #26 & #27 FOR OPTIONS. NOTE: DIRECT VENT FURNACE, FULL A/C, OUTSIDE AIR WITH DAMPER TO RETURN DUCT( ACCESS IS A 12"/12" IN KITCHEN CEILING), ELECTRIC WATER HEATER | BILLS | BILLS | | H= | P | 6075863 |
L & L GAS SHOP, LLC. | HC | C | 09/24/2018 | RELEASE METER | BILLS | BILLS | | HC | C | 5973732 |
L & L GAS SHOP, LLC. | HI | C | 09/24/2018 | CORRECTIONS MADE, SEE IMAGES | BILLS | BILLS | | HI | C | 5973731 |
L & L GAS SHOP, LLC. | HI | P | 09/20/2018 | NEED FIREPLACE FRAMING RE-INSTALLED, ( 2ND FLOOR, LEFT SIDE,,REMOVED FOR GAS LINE INSTALLATION). OK TO ATTACH PICTURES AT NEXT INSPECTION REQUEST. NOTE: 10LB TEST OK. 1 1/4" MAIN, 1 FURNACE, 1 RANGE, 2 FIREPLACES | BILLS | BILLS | | HI | P | 5970868 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 09/17/2018 | BY FINAL: INSTALL CORRECT FURNACE(70K INSTALLED, DESIGH IS A 45K). NOTE: DIRECT VENT FURNACE, A/C ROUGH COIL AND LINESET, OUTSIDE AIR WITH DAMPER TO RETURN DUCT( ACCESS IS A 12"/12" IN KITCHEN CEILING), ELECTRIC WATER HEATER | BILLS | BILLS | | HRR | C | 5966805 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | T | 09/14/2018 | PAID (REC#1537405): NO CORRECTIONS MADE, WILL REQUIRE A 4TH INSPECTION | BILLS | BILLS | | HRR | T | 5965254 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 09/13/2018 | INSTALL CORRECT FURNACE, DAMPER OUTSIDE AIR, REPAIR ARMAFLEX THROUGHOUT GARAGE ATTIC, ADD SUPPORTS TO ALL UPPER LEVEL EXHAUST FLEX'S. | BILLS | BILLS | | HRR | P | 5964462 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 09/12/2018 | WRONG FURNACE INSTALLED, DESIGN CALLS FOR 45K, 70K INSTALLED Equipment installed does not match equipment listed on approved duct design. Contractor must fill out the Equipment Change Form (Residential) and attach form to an inspection request by final. Form can be found on the PPRBD website under Downloads, Residential Handouts, Equipment Change Residential Duct Design. / ,, OUTSIDE AIR TO BE DAMPERED, BEING USED AS VENTILATION AIR ONLY( WILL NEED ACCESS TO DAMPER ALSO), ISOLATE MAIN LEVEL RETURN AIR FROM CHASE, ALL UPPER LEVEL EXHAUST'S NEED ADDITIONAL SUPPORT, REPAIR ARMAFLEX THROUGHOUT GARAGE, ARMAFLEX TO CONTINUE TO EXTERIOR. NOTE: DIRECT VENT FURNACE, A/C ROUGH COIL AND LINESET, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | HRR | P | 5962371 |
DMB PLUMBING SERVICES INC. | P= | C | 02/11/2019 | | TAYLOR | TAYLOR | | P= | C | 6103695 |
DMB PLUMBING SERVICES INC. | P= | P | 01/28/2019 | complete master shower, install dishwasher to verify hi- loop, need trap guard at laundry room, rest ok. | TAYLOR | TAYLOR | | P= | P | 6090273 |
DMB PLUMBING SERVICES INC. | P= | P | 01/28/2019 | certificate of potable water to images | TED | TED | | P= | P | 6089462 |
HOMEOWNER | PWO | C | 11/06/2018 | need certificate of potable water by final, no yard hydrants | TED | TED | | PWO | C | 6017477 |
DMB PLUMBING SERVICES INC. | PTO | C | 09/04/2018 | Need backflow protection for yard hydrant by final, still need PWO inspection, check water heater connections at final. Tempering for master tub at final, aav in wall right hand side of washer box. | JOSEPHD | JOSEPHD | | PTO | C | 5953820 |
DMB PLUMBING SERVICES INC. | PB | C | 07/03/2018 | note: water lines run under slab for kitchen, 2 lines stubbed out under footer | JOSEPHD | JOSEPHD | | PB | C | 5892858 |
HOMEOWNER | XMS | T | 08/22/2018 | PAID (REC#1541322) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: REVISED DUCT DESIGN AND HEATLOSS CALCULATIONS FOR REVISED HVAC EQUIPMENT | JUSTINC | JUSTINC | | XMS | T | 5942587 |