CREEKSTONE DEVELOPMENT, INC. | B= | C | 09/26/2018 | Unfinished basement -- Rear deck | DAKOTAB | DAKOTAB | | B= | C | 5977546 |
CREEKSTONE DEVELOPMENT, INC. | BSP | P | 08/22/2018 | 4 deck piers OK | DAKOTAB | DAKOTAB | | BSP | P | 5942633 |
CREEKSTONE DEVELOPMENT, INC. | BIN | C | 08/14/2018 | Training with Chuck | DAKOTAB | DAKOTAB | | BIN | C | 5933708 |
CREEKSTONE DEVELOPMENT, INC. | BFR | C | 08/14/2018 | Items corrected -- Training with Chuck | DAKOTAB | DAKOTAB | | BFR | C | 5933699 |
CREEKSTONE DEVELOPMENT, INC. | BSP | T | 08/13/2018 | PAID (REC#1526461) ADDITIONAL PLAN REVIEW TIME: $50 From: BECKYA Added windows and relocated door in outer garage wall | BECKYA | BECKYA | | BSP | T | 5931590 |
CREEKSTONE DEVELOPMENT, INC. | BFR | P | 08/10/2018 | missing framing details on approved structural design for garage service door and window / missing 2nd 2x6 for post under A1 truss at rear garage wall / unfinished basement / no deck installed | BRIANB | BRIANB | | BFR | P | 5930411 |
CREEKSTONE DEVELOPMENT, INC. | BSP | P | 07/18/2018 | Front porch post and lid OK -- No portal wall frame per plan | DAKOTAB | DAKOTAB | | BSP | P | 5906959 |
CREEKSTONE DEVELOPMENT, INC. | BFD | C | 05/18/2018 | Drain is usable to street -- Damp proofing OK | DAKOTAB | DAKOTAB | | BFD | C | 5849609 |
CREEKSTONE DEVELOPMENT, INC. | BFD | P | 05/18/2018 | Verification of under drain tie in on file | DAKOTAB | DAKOTAB | | BFD | P | 5848856 |
CREEKSTONE DEVELOPMENT, INC. | BFN | C | 05/18/2018 | Engineer letter for foundation on file -- Eufer noted -- Foundation design on file (Bearing capacity verified) | DAKOTAB | DAKOTAB | | BFN | C | 5848852 |
CREEKSTONE DEVELOPMENT, INC. | BFT | C | 05/18/2018 | Engineer letter for footing on file -- Open hole on file -- 2000 PSF - Drain usable - 10% | DAKOTAB | DAKOTAB | | BFT | C | 5848845 |
CREEKSTONE DEVELOPMENT, INC. | BFT | P | 05/04/2018 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 5836425 |
CREEKSTONE DEVELOPMENT, INC. | BFN | P | 05/04/2018 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 5836424 |
HOMERUN ELECTRONICS, INC. | E= | C | 09/25/2018 | corrections made | RANDY | RANDY | | E= | C | 5975226 |
HOMERUN ELECTRONICS, INC. | E= | R | 09/24/2018 | gfci outlet in garage on stair wall----outside outlets not working----- | RANDY | RANDY | | E= | R | 5974034 |
HOMERUN ELECTRONICS, INC. | ES | C | 08/02/2018 | Residential Underground: 200 amp 3/w new res | RANDY | RANDY | | ES | C | 5921691 |
HOMERUN ELECTRONICS, INC. | ER | C | 08/02/2018 | 1-#6al,1-10,100 amp sub, irreversible ufer, unfinished basement, no vac, a/c stub | RANDY | RANDY | | ER | C | 5921677 |
THE FURNACE GUY HEATING & COOLING | H= | C | 09/13/2018 | Note-- Gas meter not set at time of final. | JEFFL | JEFFL | | H= | C | 5963796 |
THE FURNACE GUY HEATING & COOLING | H= | P | 09/12/2018 | Furnace vent terminations not complete. Notes-- Unfinished basement. Outside air to return. No AC. Direct vent furnace.
| JEFFL | JEFFL | | H= | P | 5962438 |
FIREPLACE WAREHOUSE | HC | C | 08/09/2018 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5929068 |
FIREPLACE WAREHOUSE | HI | C | 08/09/2018 | 10 lb test ok notes-- 3/4'' medium pressure line to manifold in mechanical room. 1 furnace.. 1 water heater.. 1 fireplace.. 1 range.. 1 dryer.. 1 bbq.. | JEFFL | JEFFL | | HI | C | 5929065 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 08/02/2018 | Direct vent furnace. No AC. Outside air to return. Unfinished basement. | JEFFL | JEFFL | | HRR | C | 5922060 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 09/25/2018 | Correction made | MALYNDA | MALYNDA | | P= | C | 5975775 |
SPRINGS CUSTOM PLUMBING, INC. | P= | P | 09/24/2018 | Still need aav at basement lav, rest ok. | MALYNDA | MALYNDA | | P= | P | 5974097 |
SPRINGS CUSTOM PLUMBING, INC. | P= | P | 09/21/2018 | Water leak under kitchen sink, secure shower head in master, no hot water to master tub, need aav at basement lav. Note: pvb installed, unfinished basement | MALYNDA | MALYNDA | | P= | P | 5972770 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 08/02/2018 | correction made | JOSEPHD | JOSEPHD | | PTO | C | 5921945 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | P | 08/01/2018 | low test | JOSEPHD | JOSEPHD | | PTO | P | 5920257 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | P | 07/31/2018 | Still low dwv test upstairs bathrooms, leak 3" main right side of fire place. | DANR | DANR | | PTO | P | 5919146 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | P | 07/30/2018 | low test on dwv for upstairs bathrooms, rest ok note: unfinished basement, irrigation stub, aav @ washer box LH wall, basement lav | JOSEPHD | JOSEPHD | | PTO | P | 5917422 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 05/30/2018 | | CALE | CALE | | PB | C | 5859493 |