COLORADO STRUCTURES INC | B= | C | 02/25/2019 | All other required Final inspections are complete. (This is a computer generated result) | BRIANB | BRIANB | | B= | C | 6116845 |
COLORADO STRUCTURES INC | B= | P | 02/19/2019 | corrections okay / pending other final inspections. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), INTERSTATE MECHANICAL, INC. Mechanical Final Inspection is not Completed yet. | BRIANB | BRIANB | | B= | P | 6110297 |
COLORADO STRUCTURES INC | B= | P | 02/01/2019 | fitting rooms are incomplete and need complete re-inspection per 03 ANSI requirements / missing protection for p-trap under break room sink / missing signage at both restrooms / both men's and women's restroom sink hardware are incomplete and missing protection for p-trap under sinks / bottom of 18" vertical grab bar in women's restroom is installed below 39" / door hardware incomplete at janitors closet / need to complete other final inspections / note only - dbl keyed locks are blanked off at interior vestibule doors at time of inspection -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 6094835 |
COLORADO STRUCTURES INC | BFR | P | 01/18/2019 | observation letter for structural connections, reinforcing steel, masonry on file | BRIANB | BRIANB | | BFR | P | 6082244 |
COLORADO STRUCTURES INC | BFR | R | 01/15/2019 | missing permitted address on observation letter for structural connections, reinforcing steel, masonry uploaded to inspection request | BRIANB | BRIANB | | BFR | R | 6078133 |
COLORADO STRUCTURES INC | BLA | C | 01/08/2019 | front elevation | BRIANB | BRIANB | | BLA | C | 6071817 |
COLORADO STRUCTURES INC | BIN | P | 12/27/2018 | remainder of exterior thermal complete with R13 batts/pending Com Check updated | SCOTTS | SCOTTS | | BIN | P | 6063604 |
COLORADO STRUCTURES INC | BIN | P | 12/26/2018 | exterior thermal inspection -- revise com check/com check calls for R10 batts and R3.5 continuous/ R13 batts currently installed/exterior thermal complete at office areas on south end | SCOTTS | SCOTTS | | BIN | P | 6062451 |
COLORADO STRUCTURES INC | BFR | P | 12/11/2018 | PARTIAL FRAMING INSPECTION -- type IIB construction interior light gauge steel framing ok/reviewed accessibility -- fur out framing on exterior walls ok | SCOTTS | SCOTTS | | BFR | P | 6049006 |
COLORADO STRUCTURES INC | BFR | P | 11/29/2018 | PARTIAL / store front framing okay only / observation letter for structural steel, cmu, welding and bolting from CTL to follow / still need to inspect interior light gauge framing | BRIANB | BRIANB | | BFR | P | 6037728 |
COLORADO STRUCTURES INC | BFI | C | 10/30/2018 | foundation inspections complete - all paper work on file | BRIANB | BRIANB | | BFI | C | 6009696 |
COLORADO STRUCTURES INC | BFN | C | 10/29/2018 | engineers observation letter on file | BRIANB | BRIANB | | BFN | C | 6008432 |
COLORADO STRUCTURES INC | BFT | C | 10/29/2018 | engineers observation letter on file | BRIANB | BRIANB | | BFT | C | 6008431 |
COLORADO STRUCTURES INC | BFI | P | 08/23/2018 | Remainder of foundation insulation OK per plans / still need all third party observations to complete BFT, BFN and BFI / training with Chuck | RICHB | RICHB | | BFI | P | 5944155 |
COLORADO STRUCTURES INC | BFI | P | 08/22/2018 | Need to complete all third party inspections for BFT/BFN / Perimeter foundation R10 insulation grid 1 and 2 installed / Training with Chuck. | RICHB | RICHB | | BFI | P | 5942442 |
BIBLE ELECTRIC, INC. | E= | C | 02/06/2019 | | CRAIGS | CRAIGS | | E= | C | 6099070 |
BIBLE ELECTRIC, INC. | E= | P | 01/30/2019 | 9 - RTU's 1 - 80 amp , 5 - 60 amp , 2 - 30 amp , 1 - 15 amp , 1- 30 amp compressor | TOMC | TOMC | | E= | P | 6092032 |
BIBLE ELECTRIC, INC. | E= | P | 01/29/2019 | interior lights and receptacles ( except bathrooms ) , riser room , cash register line panels 480 volt --- MDP , M , HA , 120 volt LA , LB , CR | TOMC | TOMC | | E= | P | 6090704 |
BIBLE ELECTRIC, INC. | EP | C | 01/28/2019 | corrections made on bonding to building steel and AIC labeling of required panels | CHIPO | CHIPO | | EP | C | 6089808 |
BIBLE ELECTRIC, INC. | EP | P | 01/25/2019 | Need to bond trans. to bldg. steel / Need label with actual Fault Curent and date on required panels / | ROB | ROB | | EP | P | 6088305 |
BIBLE ELECTRIC, INC. | ER | P | 01/22/2019 | Grid ceilings ok in rooms 106, 107,109A, 109C, 114, 116, 118 / | ROB | ROB | | ER | P | 6084621 |
BIBLE ELECTRIC, INC. | ER | R | 01/18/2019 | rooms -- 101--110--115--113--112--- above ceiling and hard rock ceilings | CRAIGS | CRAIGS | | ER | R | 6082460 |
COLORADO ELECTRICAL SYSTEMS, LLC | E= | C | 01/17/2019 | FIRE ALARM INSPECTION: FA complete / | ROB | ROB | | E= | C | 6081078 |
COLORADO ELECTRICAL SYSTEMS, LLC | ER | C | 01/17/2019 | FIRE ALARM INSPECTION: FA rough ok / | ROB | ROB | | ER | C | 6081062 |
COLORADO ELECTRICAL SYSTEMS, LLC | E= | C | 01/17/2019 | FIRE ALARM INSPECTION: FA rough ok / | ROB | ROB | | E= | C | 6081063 |
BIBLE ELECTRIC, INC. | ER | P | 01/16/2019 | Crimp ok for extension of ufer to disconnect / | ROB | ROB | | ER | P | 6079735 |
BIBLE ELECTRIC, INC. | ER | R | 01/15/2019 | splice the plans to show 500 al instead of 350 copper as called for --- need to see the ufer connection to the footer rebar --- install all labels required on the outside service disconnect | CRAIGS | CRAIGS | | ER | R | 6079287 |
BIBLE ELECTRIC, INC. | ES | C | 01/15/2019 | Commercial Service: 600 amp 4/w 480/277 volt OK to set ct's / wire ct's and energize | CRAIGS | CRAIGS | | ES | C | 6079286 |
BIBLE ELECTRIC, INC. | ER | P | 01/02/2019 | Rough ok for colums / Rough ok for south and west wall of main entry / | ROB | ROB | | ER | P | 6066493 |
BIBLE ELECTRIC, INC. | ER | P | 12/13/2018 | Rough in ok for all walls on south end of building / Discussed accessibility requirements with contractor / | ROB | ROB | | ER | P | 6052177 |
BIBLE ELECTRIC, INC. | EUG | P | 11/15/2018 | 4- 4"PVC from trans. to bldg. wall / | ROB | ROB | | EUG | P | 6026751 |
BIBLE ELECTRIC, INC. | EUG | P | 11/09/2018 | EUG for electrical room ok / | ROB | ROB | | EUG | P | 6021424 |
BIBLE ELECTRIC, INC. | EUG | P | 11/07/2018 | 4--11/4"and 2--1" completed and turned up at front of store---2--4" communication pipes completed in SE corner building / | ROB | ROB | | EUG | P | 6018466 |
BIBLE ELECTRIC, INC. | EUG | P | 10/31/2018 | 2-4" PVC communications connected to stubs across back drive / | ROB | ROB | | EUG | P | 6011575 |
BIBLE ELECTRIC, INC. | EUG | P | 10/30/2018 | Communication ok out east side to back of building / CSU looked at primary / | ROB | ROB | | EUG | P | 6009942 |
BIBLE ELECTRIC, INC. | EUG | P | 10/18/2018 | 4 --1 1/4 and 2 -- 1" pvc under slab to the front of the store | CRAIGS | CRAIGS | | EUG | P | 5998630 |
BIBLE ELECTRIC, INC. | ER | P | 08/17/2018 | UFER 3/0 location SW corner of structure | CHIPO | CHIPO | | ER | P | 5937653 |
INTERSTATE MECHANICAL, INC. | H= | C | 02/25/2019 | | MARKB | MARKB | | H= | C | 6116844 |
COLORADO MECHANICAL SYSTEMS, LLC | H= | C | 02/01/2019 | TEST AND BALANCE REPORT RECEIVED | MARKB | MARKB | | H= | C | 6094529 |
COLORADO MECHANICAL SYSTEMS, LLC | H= | P | 01/25/2019 | FINAL PENDING - Test And Balance Report | MARKB | MARKB | | H= | P | 6089018 |
COLORADO MECHANICAL SYSTEMS, LLC | HD | C | 01/24/2019 | FOR FINAL - RTU'S 1 & 2 pan off return air gap on bottom side, finish condensate disposal and vent terminations on all RTU'S, label all equipment, install thermostats or sensors, need flex and diffuser in storage by cash out, complete condensate disposal for mini-split, fasten down mini-split condenser, need to inspect vent for unit heater and provide test and balance report. ABOVE CEILING DUCT - ALL FLEX/DIFFUSERS COMPLETE. SMOKE SHUTDOWN VERIFIED. Training with Bill S. | MARKB | MARKB | | HD | C | 6087780 |
COLORADO MECHANICAL SYSTEMS, LLC | HD | P | 01/17/2019 | ABOVE CEILING DUCT - SUPPLY/EXHAUST MAINS/BRANCHES ABOVE HARD LIDS AND FOR RTU'S 7, 8, 9 OK TO INSULATE AND CONCEAL. No flex or diffusers | MARKB | MARKB | | HD | P | 6081628 |
INTERSTATE MECHANICAL, INC. | HC | C | 01/16/2019 | OK TO RELEASE 2 PSI METER | MARKB | MARKB | | HC | C | 6080598 |
INTERSTATE MECHANICAL, INC. | HI | C | 01/16/2019 | ALL GAS CONNECTIONS COMPLETE TO EQUIPMENT WITH REGULATORS. Still need medium pressure labels installed. | MARKB | MARKB | | HI | C | 6080589 |
INTERSTATE MECHANICAL, INC. | HI | P | 01/10/2019 | Need all open valves plugged in order to release meter. 2 PSI APPROVAL LETTER FROM CSU ON FILE. 10 PSI PRESSURE TEST AND PIPING PER PLAN OK. Still need for final - medium pressure stickers, regulators and equipment installed.
| MARKB | MARKB | | HI | P | 6075417 |
INTERSTATE MECHANICAL, INC. | P= | C | 02/08/2019 | Ok. | DANR | DANR | | P= | C | 6102003 |
INTERSTATE MECHANICAL, INC. | PTO | C | 01/31/2019 | Ok for over head piping to roof hydrants and drain downs, water entry. Note: by final need isolation valve line feeding roof hydrant by restrooms - support line to trap primer in water entry - floor sink in water entry needs strainer - expose pipe wrap water entry pipe. | DANR | DANR | | PTO | C | 6093767 |
INTERSTATE MECHANICAL, INC. | PTO | P | 12/18/2018 | In wall and over head dwv and domestic water ok for rooms 110-111-121- and mop sink room. Note: in floor trap primers, check water heater and water entry at final. | DANR | DANR | | PTO | P | 6056169 |
INTERSTATE MECHANICAL, INC. | PB | C | 11/27/2018 | Switched to PB inspection, water stub ok. Note: CSU inspects outside of building. | DANR | DANR | | PB | C | 6034998 |
INTERSTATE MECHANICAL, INC. | PB | P | 09/14/2018 | Ok. except water stub. | DANR | DANR | | PB | P | 5965919 |
INTERSTATE MECHANICAL, INC. | PB | P | 09/13/2018 | Need branch line to break sink, rest ok. | DANR | DANR | | PB | P | 5964646 |
BIBLE ELECTRIC, INC. | XES | T | 01/22/2019 | PAID (REC#1571797): PLAN SPLICE FEE: $50 by: BERTHA for Electrical: Revised conductors - CU to AL - Revision 5 only. | BERTHA | BERTHA | | XES | T | 6084599 |
COLORADO STRUCTURES INC | XBS | P | 01/10/2019 | PLAN SPLICE: (No Fee) by: MICHAELA for Construction: Revise IECC | MICHAELA | MICHAELA | | XBS | P | 6074929 |