HOMEOWNER | B= | P | 11/25/2019 | . Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | NATHAN | NATHAN | | B= | P | 6409426 |
HOMEOWNER | BIN | C | 11/25/2019 | insulation has been verified | NATHAN | NATHAN | | BIN | C | 6409424 |
HOMEOWNER | BFR | C | 11/25/2019 | | NATHAN | NATHAN | | BFR | C | 6409417 |
HOMEOWNER | BE | L | 11/25/2019 | Renewed for No Fee at 11/25/2019 8:26:35 AM | TERRI | TERRI | | BE | L | 6409273 |
HOMEOWNER | BSP | P | 09/10/2018 | Drywall fastening on South & East walls (both levels) OK | RICHB | RICHB | | BSP | P | 5960310 |
HOMEOWNER | BSP | P | 09/07/2018 | stamped openex on file. | NATHAN | NATHAN | | BSP | P | 5957748 |
HOMEOWNER | BFR | P | 09/06/2018 | drywall at rafters on east and south wall upstairs need 7" oc nailing at all drywall east and south walls garage and upstairs, frame items corrected | NATHAN | NATHAN | | BFR | P | 5957246 |
HOMEOWNER | BIN | P | 09/06/2018 | rated wall and roof rim okay, garage ceiling, walls and east, north and south walls upstairs insulation okay. | NATHAN | NATHAN | | BIN | P | 5957243 |
HOMEOWNER | BSP | P | 08/28/2018 | deck piers and frame okay | NATHAN | NATHAN | | BSP | P | 5947990 |
HOMEOWNER | BFR | P | 08/28/2018 | need stamped open excavation, strap top plates throughout upstairs, okay to insulate | NATHAN | NATHAN | | BFR | P | 5947987 |
HOMEOWNER | BSP | P | 07/27/2018 | site visit - for demo on front deck | LONNYS | LONNYS | | BSP | P | 5917132 |
HOMEOWNER | BSP | P | 07/25/2018 | diameter and depth okay image of bottom of sonotube removed needed for completion. | NATHAN | NATHAN | | BSP | P | 5913382 |
HOMEOWNER | BFI | C | 06/08/2018 | 24" R-10 | SHAUN | SHAUN | | BFI | C | 5868683 |
HOMEOWNER | BFN | C | 06/06/2018 | ufer is in | NATHAN | NATHAN | | BFN | C | 5865949 |
HOMEOWNER | BFI | R | 06/05/2018 | Not ready | SHAUN | SHAUN | | BFI | R | 5864432 |
HOMEOWNER | BFN | R | 06/05/2018 | Not ready | SHAUN | SHAUN | | BFN | R | 5864426 |
HOMEOWNER | BFI | R | 06/04/2018 | not ready need foundation inspection | NATHAN | NATHAN | | BFI | R | 5863054 |
HOMEOWNER | BFT | C | 06/01/2018 | 2400 psf soils okay | NATHAN | NATHAN | | BFT | C | 5862057 |
HOMEOWNER | E= | C | 01/09/2019 | | CRAIGS | CRAIGS | | E= | C | 6073855 |
HOMEOWNER | E= | R | 01/08/2019 | upper unit has no power to the west counter top outlets/ the other corrections were made | BRIAN | BRIAN | | E= | R | 6071636 |
HOMEOWNER | E= | R | 01/03/2019 | LOWER UNIT--need to hard wire the water heater to a disconnect can not use cord / need at least 1 hard wired light in the garage UPPER UNIT---need a wr grci outlet on porch / need dedicated 20 amp for laundry/ washer can not use kitchen circuit / | BRIAN | BRIAN | | E= | R | 6067395 |
HOMEOWNER | ES | C | 12/05/2018 | Residential Overhead: 200 amp 3-w new res and detached---ok to set meters in upper and lower units--- | BRIAN | BRIAN | | ES | C | 6043504 |
HOMEOWNER | EP | R | 11/20/2018 | verify call ahead # no one on site -----no access to verify ufer----meter can not be over 6' to center per CSU standards---lower meter cover screwed on could not open---complete reinspect---- | BRIAN | BRIAN | | EP | R | 6030643 |
HOMEOWNER | ES | R | 09/05/2018 | service disconnects have to be grouped --- call me in the morning @ 327-2902 between 7:30 and 8:30 to discuss this | CRAIGS | CRAIGS | | ES | R | 5955181 |
HOMEOWNER | ER | C | 08/24/2018 | Scope of work: apartment up stairs on it's own meter,,,, garage: down below, on it's own meter | GARYL | GARYL | | ER | C | 5945532 |
HOMEOWNER | H= | C | 08/27/2018 | Changed from HI to H=. One bathroom fan only. Electric heat, no gas. | RANDYB | RANDYB | | H= | C | 5947230 |
HOMEOWNER | HRR | C | 08/24/2018 | Bath fan only. | MARK | MARK | | HRR | C | 5945735 |
HERMANS PLUMBING SERVICE, INC | P= | C | 01/10/2019 | Corrections made. | DANR | DANR | | P= | C | 6074258 |
HERMANS PLUMBING SERVICE, INC | P= | P | 01/09/2019 | Need access to check main house water connection, hammer arrestor dish washer, laundry aav, water heater expansion devise, rest ok. | DANR | DANR | | P= | P | 6072876 |
HERMANS PLUMBING SERVICE, INC | PTO | C | 08/10/2018 | Test ok. Note: aav laundry and kitchen, check water heater and water service connections at final, drawings show heated garage. | DANR | DANR | | PTO | C | 5930078 |
HERMANS PLUMBING SERVICE, INC | PB | C | 06/08/2018 | Ok. Note: house behind 1105. | DANR | DANR | | PB | C | 5868701 |
HOMEOWNER | XMS | T | 08/23/2018 | PAID (REC#1530154) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: changed heating system to electric heat | DALEH | DALEH | | XMS | T | 5944042 |