HOMEOWNER | B= | C | 08/12/2019 | All other required Final inspections are complete. (This is a computer generated result) | NATHAN | NATHAN | | B= | C | 6296375 |
HOMEOWNER | B= | P | 07/24/2019 | conditioned crawlspace, a/c installed. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | NATHAN | NATHAN | | B= | P | 6276007 |
HOMEOWNER | BSP | P | 12/19/2018 | Frame okay | TRENTP | TRENTP | | BSP | P | 6058175 |
HOMEOWNER | BSP | P | 12/13/2018 | deck pier inspection and front porch post letter on file | NATHAN | NATHAN | | BSP | P | 6052700 |
HOMEOWNER | BLA | C | 12/13/2018 | | NATHAN | NATHAN | | BLA | C | 6052699 |
HOMEOWNER | BIN | C | 11/27/2018 | | NATHAN | NATHAN | | BIN | C | 6035661 |
HOMEOWNER | BFR | P | 11/20/2018 | need rear deck pier and frame inspection and front and rear post connections per plan, okay to insulate | NATHAN | NATHAN | | BFR | P | 6031594 |
HOMEOWNER | BFR | P | 11/16/2018 | mechanical connections add top plates garage wall, nail garage portal frame per D1 14, truss clips at mech room over walls, QQ girder missing posts, and straps per plan, need bearing blocks at QQ girder, need front gable over frame osb cut back to 30" minimum, need correct hardware at porch posts top and bottom, missing hanger at mechanical headout in crawspace, A1 truss clips at garage to house wall, okay to insulate,======== rear deck and piers need inspection still======== | NATHAN | NATHAN | | BFR | P | 6028811 |
HOMEOWNER | BFD | C | 08/16/2018 | drain is usable to daylight at north end east corner | NATHAN | NATHAN | | BFD | C | 5936746 |
HOMEOWNER | BFN | C | 08/13/2018 | all paperwork on file, ufer is in east side of garage south end, interior pads okay | NATHAN | NATHAN | | BFN | C | 5931460 |
HOMEOWNER | BFT | C | 08/13/2018 | stamped openex and foundation print on file. soils and plan matched at 2400 psf | NATHAN | NATHAN | | BFT | C | 5931455 |
HOMEOWNER | BFN | P | 08/08/2018 | Interior pads formed / ufer is in need all foundation paperwork | NATHAN | NATHAN | | BFN | P | 5927893 |
HOMEOWNER | BFT | P | 08/08/2018 | with all completed paperwork uploaded footer okay still need open excavation for bearing pressure confirmation. | NATHAN | NATHAN | | BFT | P | 5927886 |
HOMEOWNER | BFT | R | 07/26/2018 | POUR AT OWN RISK PENDING SOIL BEARING VERIFICATION OF 4000 PSF, INTERIOR PADS AND NOT READY AT THIS TIME, buttress walls are internal so they cannot be used as rear porch support | NATHAN | NATHAN | | BFT | R | 5915471 |
AMPED UP ELECTRIC, LLC, DBA ACE ELECTRIC | E= | C | 07/17/2019 | 20A A/C ok / 30A WH / | MIGUEL | MIGUEL | | E= | C | 6266941 |
AMPED UP ELECTRIC, LLC, DBA ACE ELECTRIC | ER | C | 11/07/2018 | corrections made / | MIGUEL | MIGUEL | | ER | C | 6018371 |
AMPED UP ELECTRIC, LLC, DBA ACE ELECTRIC | ES | C | 11/06/2018 | Residential Underground: 200A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 6017496 |
AMPED UP ELECTRIC, LLC, DBA ACE ELECTRIC | ER | R | 11/06/2018 | install raceway with pullstring to floor from j boxes labeled floor heat in bathrooms------IR ufer connection--10/2,WH---3-10/3, dryer, range, A/C---6/3CU, oven--no central vac---crawler | MIGUEL | MIGUEL | | ER | R | 6017486 |
HOMEOWNER | H= | C | 07/19/2019 | RECEIVED IMAGES OF CORRECTIONS FROM HOMEOWNER, SEE IMAGES. | MATTM | MATTM | | H= | C | 6270863 |
HOMEOWNER | H= | P | 07/19/2019 | FURNACE CONCENTRIC TERMINATION REQUIRES AN EXHAUST ACCELERATOR (REDUCER) PER MANUFACTURES INSTALLATION INSTRUCTIONS PAGE 24 TABLE 9 FIGURE 35, MECHANICALLY LOCK ALL SUPPLY DAMPERS IN THE OPEN POSITION IN CRAWLSPACE, OK TO SEND PICTURES TO MATTM@PPRBD.ORG | MATTM | MATTM | | H= | P | 6269772 |
HOMEOWNER | H= | P | 07/19/2019 | received change of equipment letter for furnace and coil. SEE IMAGES. | PAULO | PAULO | | H= | P | 6269460 |
HOMEOWNER | H= | P | 07/02/2019 | FURNACE, COIL AND CONDENSER INSTALLED DOES NOT MATCH EQUIPMENT LISTED ON APPROVED DUCT DESIGN. CONTRACTOR MUST FILL OUT THE EQUIPMENT CHANGE FORM (RESIDENTIAL) AND ATTACH FORM TO NEXT INSPECTION REQUEST. FORM CAN BE FOUND ON THE PPRBD WEBSITE UNDER DOWNLOADS, RESIDENTIAL HANDOUTS, EQUIPMENT CHANGE RESIDENTIAL DUCT DESIGN. NEED PLAN SPLICE FOR FLEX DUCT INSTALLED IN CRAWLSPACE, PROVIDE FURNACE INSTALLATION INSTRUCTIONS AT NEXT INSPECTION REQUEST, FURNACE VENT TERMINATION IS INCOMPLETE, ALL CRAWLSPACE SUPPLY DAMPERS NEED TO BE LOCKED IN THE OPEN POSITION. NOTES: CONDITIONED CRAWLSPACE (4 SUPPLY 1 RETURN), OUTSIDE AIR TO FURNACE RETURN W/ BACK DRAFT DAMPER, DIRECT VENT FURNACE, ELECTRIC WATER HEATER, A/C INSTALLED, 1 FIREPLACE | MATTM | MATTM | | H= | P | 6251478 |
VIC'S LLC | HC | C | 11/12/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 6022965 |
VIC'S LLC | HRR | C | 11/12/2018 | NEEDED BY FINAL-- ALL S.A. FLEX DUCT TO BE REMOVED AND REPLACED WITH RIGID PER PLANS OR A SPLICE FOR ALL FLEX DUCT INSTALLED, CHANGE OF EQUIPMENT LETTER FOR FURNACE AND COIL, R.A. IN CRAWL SPACE FOR CONDITIONING, DAMPER TO OUTSIDE AIR PER THE IECC 403.5 (OUTSIDE AIR TO RETURN NOT BEING USED FOR COMBUSTION AIR). note: crawl space, outside air to return, direct vent down flow furnace, electric water heater, a/c rough and line set. | PAULO | PAULO | | HRR | C | 6022964 |
L & L GAS SHOP, LLC. | HI | C | 11/08/2018 | 10 LB TEST OK ,1 INCH MAIN , 1 FURNACE , 1 FIRE PLACE 1 RANGE | ANDREWP | ANDREWP | | HI | C | 6020641 |
VIC'S LLC | HRR | P | 11/02/2018 | need to address the following-- fire place and fire place vent to be completed for inspection. NEEDED BY FINAL-- ALL S.A. FLEX DUCT TO BE REMOVED AND REPLACED WITH RIGID PER PLANS OR A SPLICE FOR ALL FLEX DUCT INSTALLED, CHANGE OF EQUIPMENT LETTER FOR FURNACE AND COIL, R.A. IN CRAWL SPACE FOR CONDITIONING, DAMPER TO OUTSIDE AIR PER THE IECC (OUTSIDE AIR NOT BEING USED FOR COMBUSTION AIR). note: crawl space, outside air to return, direct vent down flow furnace, electric water heater, a/c rough and line set. | PAULO | PAULO | | HRR | P | 6014618 |
JOLLY PLUMBING & HEATING INC. | P= | C | 07/16/2019 | correction made see image (recirc pump) | JOSEPHD | JOSEPHD | | P= | C | 6264143 |
JOLLY PLUMBING & HEATING INC. | P= | P | 07/12/2019 | update from previous inspection recirc pump will need to be on water heater side of check valve | JOSEPHD | JOSEPHD | | P= | P | 6261150 |
JOLLY PLUMBING & HEATING INC. | P= | P | 07/11/2019 | will need to conduct more research into recirc pump piped into cold water before the check valve, rest ok note: pvb installed | JOSEPHD | JOSEPHD | | P= | P | 6259856 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 10/26/2018 | check water htr / expansion / drain pan @ final, crawl space (no drains), vtr (1), aav @ washer box @ right side in aav box, laundry sink, and hall lav, irrigation stub | JOHNS | JOHNS | | PTO | C | 6007293 |
JOLLY PLUMBING & HEATING INC. | PTO | R | 10/25/2018 | Not ready | SHANEN | SHANEN | | PTO | R | 6006627 |
HOMEOWNER | XMS | P | 07/18/2019 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Mechanical: Revised (2) duct runs to flex | TCRIPPEN | TCRIPPEN | | XMS | P | 6268056 |