HOMEOWNER | B= | C | 05/31/2019 | Final inspection corrections complete / NOTE: if basement is finished at later date - will require separate permit and inspections | JUSTINL | JUSTINL | | B= | C | 6216884 |
HOMEOWNER | B= | R | 05/30/2019 | 1. Missing handrail at mud room right side garage / 2. Seal penetration at plumbing pipe in mud room for garage to dwelling separation / 3. Handrail to basement missing return at top and bottom / 4. Missing landing at rear deck stairs - To be 36" in direction of travel and as wide as stairs / 5. Missing continuous graspable handrail at rear deck stairs / 6. finish final grade at rear elevation to end of deck / Unfinished basement / Rear deck | JUSTINL | JUSTINL | | B= | R | 6215438 |
HOMEOWNER | BLA | C | 02/27/2019 | | LONNYS | LONNYS | | BLA | C | 6118666 |
HOMEOWNER | BLA | P | 02/25/2019 | extend electric boxes to front of pop-outs thru-out | DALE | DALE | | BLA | P | 6116840 |
HOMEOWNER | BIN | C | 01/18/2019 | | LONNYS | LONNYS | | BIN | C | 6082612 |
HOMEOWNER | BFR | C | 01/16/2019 | | LONNYS | LONNYS | | BFR | C | 6079703 |
HOMEOWNER | BSP | P | 01/11/2019 | received engineer letter for garage narrow braced wall - floor framing rear north garage - hole in LVL rear N garage | LONNYS | LONNYS | | BSP | P | 6075976 |
HOMEOWNER | BFR | P | 01/11/2019 | THASR29 hanger nailing incomplete all connections to HG1 in garage / missing 2nd TBE throughout / missing 4th 2x4 post under HG2 garage mud room / fire block incomplete several concealed spaces / cut code compliant access to over framing / strap top plate break right of slider mother in law master / secure post bases and post cap in crawler / wood shims used in crawler / untreated post in contact with footer in crawler / missing point load for upper lever post next to fireplace to foundation | LONNYS | LONNYS | | BFR | P | 6075972 |
HOMEOWNER | BSP | P | 11/19/2018 | eng. received for rear porch beam, rear porch frame ok | DALE | DALE | | BSP | P | 6030203 |
HOMEOWNER | BSP | R | 11/09/2018 | garage narrow wall does not meet minimum width requirements missing interior straps/ rear big porch beam hangered to exterior wall not per approved detail / front porch posts and lids OK / rear small porch post and lid OK | LONNYS | LONNYS | | BSP | R | 6021344 |
HOMEOWNER | BSP | P | 09/28/2018 | 3 rear piers ok | DALE | DALE | | BSP | P | 5980773 |
HOMEOWNER | BFI | C | 09/04/2018 | 2" R10 rigid OK at walkout | LONNYS | LONNYS | | BFI | C | 5954223 |
HOMEOWNER | BFD | C | 09/04/2018 | drain is usable to SW corner of walkout / damp proofing OK | LONNYS | LONNYS | | BFD | C | 5954218 |
HOMEOWNER | BFN | C | 08/27/2018 | received open hole - 3000PSF - usable - 10% / received soils report / received foundation design - (bearing capacity verified) / foundation forms and reinforcing OK | LONNYS | LONNYS | | BFN | C | 5946423 |
HOMEOWNER | BFT | C | 08/15/2018 | including interior pads / ufer in | DALE | DALE | | BFT | C | 5935345 |
HOMEOWNER | E= | C | 05/28/2019 | E= OK ----- | GREGM | GREGM | | E= | C | 6212115 |
HOMEOWNER | E= | R | 05/20/2019 | LAUNDRY OUTLETS ON NORTH OF HOUSE NOT GFCI PROTECTED-------OUT SIDE OUTLETS NEED TO BE WR----BASEMENT GFCI NOT WORKING------REST OK------- | GREGM | GREGM | | E= | R | 6205039 |
HOMEOWNER | ER | C | 01/07/2019 | 200 --- 1 - 1/0 ser , 2 - #6 , sub-panel in basement , sub-panel in north garage , main panel in south garage , no mcc , no central vac , unfinished basement --- talked about TR , AFCI , GFCI | TOMC | TOMC | | ER | C | 6070815 |
HOMEOWNER | ES | C | 01/03/2019 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | GREGM | GREGM | | ES | C | 6067295 |
HOMEOWNER | ES | P | 12/31/2018 | Residential Underground: 200 amp --- ok to schedule shut down to transfer power | TOMC | TOMC | | ES | P | 6066259 |
HOMEOWNER | EUG | C | 12/31/2018 | 4/0 urd | TOMC | TOMC | | EUG | C | 6066193 |
HOMEOWNER | H= | C | 05/30/2019 | Corrections Made See Images. | TREVORH | TREVORH | | H= | C | 6214052 |
HOMEOWNER | H= | R | 05/28/2019 | it appears in the photo the Bay vent is lacking 12'' of clearance from the ground, verify there is 12'' of clearance with a tape measure in the picture, for the next inspection. ( need verification the Bay vent is 12'' above the concrete slab shown in the picture.) | TREVORH | TREVORH | | H= | R | 6211270 |
HOMEOWNER | H= | R | 05/28/2019 | it appears in the photo the Bay vent is lacking 12'' of clearance from the ground, verify there is 12'' of clearance with a tape measure in the picture, for the next inspection. | TREVORH | TREVORH | | H= | R | 6211102 |
HOMEOWNER | H= | P | 05/20/2019 | need to properly terminate direct vent furnace located in crawl space OK to attach picture at next inspection request. NOTE: MOTHER IN LAW-- CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, A/C ROUGH COIL ONLY, OUTSIDE AIR TO RETURN DUCT,,,, MAIN UNIT-- UNFINISHED BASEMENT, A/C ROUGH COIL ONLY, OUTSIDE AIR TO RETURN DUCT, 3 SOLID FUEL FIREPLACES(1 FUTURE USE IN BASEMENT OF MAIN UNIT) | TREVORH | TREVORH | | H= | P | 6204888 |
HOMEOWNER | HO | C | 01/31/2019 | BY FINAL: CONFIRM 2LB LETTER FROM BLACK HILLS ENERGY. NOTE: 10LB TEST OK. 315' OF 1" POLY PIPE WITH TRACER WIRE FROM METER TO REGULATOR LOCATION | BILLS | BILLS | | HO | C | 6094060 |
HOMEOWNER | HO | P | 01/23/2019 | ENTIRE TRENCH IS FILLED WITH SNOW. CAN NOT CONFIRM TRENCH DEPTH, RISER AND GAUGE ARE BELOW GRADE IN SNOW FILLED HOLE | BILLS | BILLS | | HO | P | 6086095 |
HOMEOWNER | HC | C | 01/09/2019 | RELEASE METER 2LB SYSTEM | BILLS | BILLS | | HC | C | 6073253 |
HOMEOWNER | HRR | C | 01/09/2019 | BT FINAL: CONFIRM 2LB LETTER FROM BLACK HILLS ENERGY. NOTE: MOTHER IN LAW-- CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, A/C ROUGH COIL ONLY, OUTSIDE AIR TO RETURN DUCT,,,, MAIN UNIT-- UNFINISHED BASEMENT, A/C ROUGH COIL ONLY, OUTSIDE AIR TO RETURN DUCT, 3 SOLID FUEL FIREPLACES(1 FUTURE USE IN BASEMENT OF MAIN UNIT) | BILLS | BILLS | | HRR | C | 6073249 |
HOMEOWNER | HI | C | 12/31/2018 | 10LB TEST OK. 1 1/2" MAIN, 2 FURNACES, 2 WATER HEATERS, 1 RANGE, 1 COOKTOP, 2 DRYERS, 1 FIREPLACE | BILLS | BILLS | | HI | C | 6065920 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 12/18/2018 | MAIN HOUSE: COMPLETE MASTER FIREPLACE AND VENT, MISSING WATER HEATER VENT CHASE, BRACE,SECURE, AND LEVEL VENT. MOTHER IN LAW UNIT: CONDITION CRAWLSPACE, MISSING PANNING AND HEADERS FOR NORTH RETURN AIR, BRACE,SECURE, AND LEVEL WATER HEATER VENT. BOTH UNITS: RETURN AIRS TO CLOSE TO SOLID FUEL FIREPLACES, SEE IFCG 618.5.5.3 NOTE: MOTHER IN LAW--DIRECT VENT FURNACE, A/C ROUGH COIL ONLY, OUTSIDE AIR TO RETURN DUCT,,,, MAIN UNIT-- UNFINISHED BASEMENT, A/C ROUGH COIL ONLY, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | HRR | P | 6057003 |
HOMEOWNER | P= | C | 05/28/2019 | | TAYLOR | TAYLOR | | P= | C | 6211503 |
HOMEOWNER | P= | P | 05/20/2019 | need hi- loop and hammer arrestor at dishwasher, crossed water lines at tub in hall bath, need power supply for recirculating pump, rest ok, unfinished basement/ crawl space, no irrigation, note: certificate of potable water sent to scanning. | TAYLOR | TAYLOR | | P= | P | 6204315 |
HOMEOWNER | PTO | C | 12/31/2018 | Test ok. | DANR | DANR | | PTO | C | 6066041 |
HOMEOWNER | PTO | P | 12/17/2018 | lost test at water pipe, rest ok note: unfinished basement, cwv @ mother inlaw lav, tempering at RH master lav by final, check for backwater at KC trap in crawlspace, check connections at water main at final | JOSEPHD | JOSEPHD | | PTO | P | 6055663 |
HOMEOWNER | PWO | C | 09/14/2018 | will need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 5965440 |
HOMEOWNER | PB | C | 09/10/2018 | note: water line at foundation depth ok, will still need pwo inspection for rest of pipe run and connection at well, cwv @ basement lav on west side if jack and jill | JOSEPHD | JOSEPHD | | PB | C | 5959932 |