HOMEOWNER | B= | C | 05/08/2019 | All other required Final inspections are complete. (This is a computer generated result) | RICHB | RICHB | | B= | C | 6193128 |
HOMEOWNER | B= | P | 04/26/2019 | Previous item complete. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | RICHB | RICHB | | B= | P | 6179690 |
HOMEOWNER | B= | P | 03/25/2019 | A/C installed, rear deck and finished basement. Posted address shall be 5" high with a 1/2" wide stroke. -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | CHUCK | CHUCK | | B= | P | 6143654 |
HOMEOWNER | BLA | C | 11/27/2018 | Lath OK | RICHB | RICHB | | BLA | C | 6035188 |
HOMEOWNER | BIN | C | 10/29/2018 | Thermal OK - need to verify attic at Final | RICHB | RICHB | | BIN | C | 6008641 |
HOMEOWNER | BFR | C | 10/24/2018 | Previous items complete / NOTE - garage doors have been temporarily dried-in | RICHB | RICHB | | BFR | C | 6004522 |
HOMEOWNER | BFR | P | 10/22/2018 | Need HUS 28 and HUS28-2 reinstalled in wine cellar - many are not tight to joists, some are missing nails and most nails are not 16d (per SImpson manual and also engineered plans) / framing OK otherwise | RICHB | RICHB | | BFR | P | 6001911 |
HOMEOWNER | BSP | P | 09/21/2018 | All previous items from Sept 19th BSP have been addressed | RICHB | RICHB | | BSP | P | 5972635 |
HOMEOWNER | BSP | P | 09/19/2018 | Front porch - framing OK pending other Roughs / rear porch lid - Need HUC210-3 fully nailed (left side), need LS30's at the top chord of L2 trusses, double beam connections at shared 6x6 posts not per plans (calls for dovetailing, ST18's and LS90's) | RICHB | RICHB | | BSP | P | 5970015 |
HOMEOWNER | BFD | C | 07/26/2018 | Drain OK | JEREMYA | JEREMYA | | BFD | C | 5915272 |
HOMEOWNER | BFN | C | 07/26/2018 | Reinforcing steel observation on file // Soils on file // Eufer documented // 10% grade // 1.5" float | JEREMYA | JEREMYA | | BFN | C | 5915271 |
HOMEOWNER | BFT | C | 07/26/2018 | Reinforcing steel observation on file | JEREMYA | JEREMYA | | BFT | C | 5915266 |
HOMEOWNER | BFD | R | 07/23/2018 | need to complete all foundation inspections / drain is usable to sump at rear NE corner - damp proofing OK | LONNYS | LONNYS | | BFD | R | 5910552 |
HOMEOWNER | E= | C | 02/22/2019 | | JOHNN | JOHNN | | E= | C | 6114486 |
HOMEOWNER | E= | R | 02/20/2019 | 1) washer gfci can not be behind appliance, 2) garage door opener-test light, 3) too much stuff in garage to do inspection--- recept's not all working 4) where is gfci to w/p recept's?? it appears to be two locations, 5) switch plate missing on furnace 6) one of the closet lights too close to shelf ///// a/c installed | GARYL | GARYL | | E= | R | 6111988 |
HOMEOWNER | ER | C | 10/16/2018 | corrections made | GARYL | GARYL | | ER | C | 5996624 |
HOMEOWNER | ES | C | 10/15/2018 | Residential Underground: 200 - amp 3 Wire new service, ok to set meter / | CRAIG | CRAIG | | ES | C | 5994305 |
HOMEOWNER | ER | R | 10/15/2018 | install running board in master closet ---------- install stair lights box --------- no mcc 2 - 10/3 2 - 6/3 al Non Irreversible UFER connection / Finished Basement / No Cent Vac / home owner not here for inspection to talk about TR/AFCI/GFI and 4 dedicated circuits for 2 kitchen 1 washer 1 bath | CRAIG | CRAIG | | ER | R | 5994297 |
HOMEOWNER | H= | C | 02/22/2019 | louver door , direct vent furnace , a/c complete, finished basement | DAVIDH | DAVIDH | | H= | C | 6114711 |
HOMEOWNER | HC | C | 10/19/2018 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 6000970 |
HOMEOWNER | HI | C | 10/19/2018 | | DAVIDH | DAVIDH | | HI | C | 6000969 |
HOMEOWNER | HI | P | 10/04/2018 | all gas lines need capped or connected prior to releasing meter. 10 lb test ok note 1 1/2" main 1 furn,w/h,2 fireplaces,1 bbq,range and firepit | DAVIDH | DAVIDH | | HI | P | 5986174 |
HOMEOWNER | HRR | C | 10/04/2018 | direct vent furn no a/c , finished basement , no 6"osa | DAVIDH | DAVIDH | | HRR | C | 5986157 |
HOMEOWNER | P= | C | 03/13/2019 | Back-flow in mech room. | SAMH | SAMH | | P= | C | 6132622 |
HOMEOWNER | PTO | C | 10/04/2018 | Finished basement, irrigation RP, AAV all in basement, by final need to verify anchors in basement closet flanges | SHANEN | SHANEN | | PTO | C | 5986332 |
HOMEOWNER | PB | C | 08/14/2018 | Correction made | SHANEN | SHANEN | | PB | C | 5933784 |
HOMEOWNER | PB | P | 08/13/2018 | Low test, rest OK | SHANEN | SHANEN | | PB | P | 5932264 |