ALLENTOWN HOMES, LLC. | B= | C | 07/26/2019 | egress window installed at 44" sill height | NATHAN | NATHAN | | B= | C | 6278746 |
ALLENTOWN HOMES, LLC. | BFN | C | 07/03/2019 | all required paperwork for garage foundation and compaction on file | NATHAN | NATHAN | | BFN | C | 6252369 |
ALLENTOWN HOMES, LLC. | BFT | C | 07/03/2019 | all required paperwork for garage foundation and compaction on file | NATHAN | NATHAN | | BFT | C | 6252368 |
ALLENTOWN HOMES, LLC. | B= | R | 07/02/2019 | still need garage observation letter for compaction, footer and foundation, master bedroom window sill over 44" in height and does not meet minimum egress size. Additional Inspections Required (computer generated): GENE'S HEATING AND AIR LLC Mechanical Final Inspection is not Completed yet, L & L GAS SHOP, LLC. Mechanical Final Inspection is not Completed yet. | NATHAN | NATHAN | | B= | R | 6251931 |
ALLENTOWN HOMES, LLC. | BIN | C | 02/14/2019 | walls okay | NATHAN | NATHAN | | BIN | C | 6107721 |
ALLENTOWN HOMES, LLC. | BFR | C | 02/14/2019 | new truss detail for CG1 3 ply on file, items from frame corrected, HTT4 installed and installation okay | NATHAN | NATHAN | | BFR | C | 6107706 |
ALLENTOWN HOMES, LLC. | BLA | C | 02/04/2019 | | NICK | NICK | | BLA | C | 6097082 |
ALLENTOWN HOMES, LLC. | BFR | P | 02/04/2019 | Need to install lateral bracing for B04 and B06 trusses / Need to install bearing block for CG1 / Need to install 3 HTS16 straps both ends of CG1 / Need to install HTS20 straps for G03 and S0G girders / Need to finish nailing all hangers for S0G and G03 / Need to remove screws from S0G2 / Truss calcs on site show CG1 as 4 ply girder truss, only 3 ply at time of inspection / Need to install ST18 straps for balloon frame wall per approved plans / Need to install strap at corner of stair landing / All other framing OK / OK to insulate | NICK | NICK | | BFR | P | 6097069 |
ALLENTOWN HOMES, LLC. | BFR | P | 02/04/2019 | letter for HTT4 to substitute ST22 on file inspection still needed. | NATHAN | NATHAN | | BFR | P | 6096221 |
ALLENTOWN HOMES, LLC. | BFR | P | 01/24/2019 | Inspection for portal frame and for ST22 straps per detail 101 / Need to install interior LSTA24 straps per detail for portal frame, all other aspects of portal frame OK / Need to install ST22 strap for garage service door per approved plans, all other ST22 straps OK | NICK | NICK | | BFR | P | 6086926 |
ALLENTOWN HOMES, LLC. | BFT | P | 01/24/2019 | garage foundation paperwork needed, density test attached is for basement density test only attached. | NATHAN | NATHAN | | BFT | P | 6086638 |
ALLENTOWN HOMES, LLC. | BFN | P | 10/26/2018 | Garage footer and foundation inspection or observation letter needed. Letter for basement footer and foundation on file. | NATHAN | NATHAN | | BFN | P | 6006762 |
ALLENTOWN HOMES, LLC. | BFT | P | 10/26/2018 | Garage footer and foundation inspection or observation letter needed. Letter for basement footer and foundation on file. | NATHAN | NATHAN | | BFT | P | 6006761 |
ALLENTOWN HOMES, LLC. | BFD | C | 10/26/2018 | Garage footer and foundation letters needed. Engineer observation for basement footer and foundation only on file. Letter for foundation interceptor drain on file. | NATHAN | NATHAN | | BFD | C | 6006751 |
ALLENTOWN HOMES, LLC. | BFD | P | 09/28/2018 | Need interceptor drain observation letter, foundation drain is usable to sump pit. | NATHAN | NATHAN | | BFD | P | 5980440 |
ALLENTOWN HOMES, LLC. | BFD | P | 09/28/2018 | Need observation letter for footer, foundation and over excavation drain. Stamped open excavation and compaction on file. | NATHAN | NATHAN | | BFD | P | 5979620 |
MESA ELECTRIC, LLC. | E= | C | 06/27/2019 | corrections made / 30A A /C / hot tub set at 50A / | MIGUEL | MIGUEL | | E= | C | 6246020 |
MESA ELECTRIC, LLC. | E= | R | 06/18/2019 | no power to smokes, outlets on fireplace wall not working, add # to dead front cb's to match schedule, mian panel: label sub panels with # to match panel, strap pvc below panel, gfci outlet on patio: can not have gfci device up high, need gfci cb, need water in hot tub, did not inspect, please have control panel open for re inspect, | JOHNN | JOHNN | | E= | R | 6234900 |
MESA ELECTRIC, LLC. | ER | C | 02/06/2019 | | BRET | BRET | | ER | C | 6099449 |
MESA ELECTRIC, LLC. | ES+ | C | 02/04/2019 | both 125 amp sub panels,ok, existing circuits that were extended will need afci on final. | JOHNN | JOHNN | | ES+ | C | 6096500 |
MESA ELECTRIC, LLC. | EUG | P | 02/04/2019 | pvc from main panel to tub disco, will need another EUG from disco to tub. | JOHNN | JOHNN | | EUG | P | 6096496 |
MESA ELECTRIC, LLC. | ER | R | 02/04/2019 | need separate circuit for lift pump, #6cu in main panel needs nm connector, | JOHNN | JOHNN | | ER | R | 6096492 |
MESA ELECTRIC, LLC. | ES | C | 10/19/2018 | Residential Overhead: 200A 3w exisitng res ok for contractor to schedule switch over from overhead to underground / | MIGUEL | MIGUEL | | ES | C | 6000266 |
MESA ELECTRIC, LLC. | ES | R | 10/18/2018 | riser needs to be 1 continuous raceway, ufer needs #4cu,has #6 cu, jump water meter, disconnect gas bond per CSU | JOHNN | JOHNN | | ES | R | 5998830 |
L & L GAS SHOP, LLC. | H= | C | 07/18/2019 | | MATTM | MATTM | | H= | C | 6268987 |
GENE'S HEATING AND AIR LLC | H= | C | 07/03/2019 | RECEIVED IMAGES OF CORRECTIONS FROM CONTRACTOR, SEE IMAGES. | MATTM | MATTM | | H= | C | 6252188 |
GENE'S HEATING AND AIR LLC | H= | P | 06/28/2019 | ADD A/C TO SCOPE OF WORK, SECURE CONDENSATE DRAIN IN MECHANICAL ROOM ON WEST SIDE OF HOME, FURNACE LOCATED IN MECHANICAL ROOM IN CRAWLSPACE MISSING THE FOLLOWING: GAS PIPE GROMMET PER MANUFACTURES INSTALLATION INSTRUCTIONS PAGE 19, COMBUSTION AIR PIPE CONDENSATE TRAP PER PAGES 26 & 27, CONDENSATE DRAIN GROMMET PER PAGES 66 & 67, PRIMARY CONDENSATE DRAIN VENT PER PAGE 67 NOTES: FINISHED BASEMENT, HI/LO TRANSFERS TO MECHANICAL ROOM, CONDITIONED CRAWLSPACE, 2X OUTSIDE AIR TO FURNACE RETURN W/MOTORIZED DAMPER, 2X DIRECT VENT FURNACE, 1X A/C INSTALLED | MATTM | MATTM | | H= | P | 6248495 |
GENE'S HEATING AND AIR LLC | H= | L | 06/27/2019 | CONFIRMED CALL AHEAD AT 4:01PM, KNOCKED AND RANG DOORBELL, NO ANSWER, LEFT DOOR TAG AT 4:31PM | MATTM | MATTM | | H= | L | 6247203 |
GENE'S HEATING AND AIR LLC | H= | P | 06/27/2019 | RECEIVED COIL CHANGE OF EQUIPMENT LETTER FROM CONTRACTOR, SEE IMAGES. | MATTM | MATTM | | H= | P | 6245646 |
WESTERN FIREPLACE SUPPLY, INC. | H= | C | 06/18/2019 | | MATTM | MATTM | | H= | C | 6235353 |
GENE'S HEATING AND AIR LLC | HC | C | 01/25/2019 | RELEASE METER | PAULO | PAULO | | HC | C | 6088875 |
GENE'S HEATING AND AIR LLC | HRR | C | 01/25/2019 | NEEDED BY FINAL-- ADD DRYER EXHAUST DUCT TO THE SCOPE OF WORK, CHANGE OF EQUIPMENT LETTER FOR COIL note: finished basement, conditioned crawl space, 2- direct vent furnaces, outside air to each furnace return with motorized dampers, a/c rough and line set to furnace in crawl space. | PAULO | PAULO | | HRR | C | 6088871 |
L & L GAS SHOP, LLC. | HI | C | 01/11/2019 | 10# test ok. note: 1 1/4" main at 100' to 2- furnaces, 2- water heaters, 1- fire place, 1- bbq and 1- future stub on back side of fire place in addition. | PAULO | PAULO | | HI | C | 6076123 |
WESTERN FIREPLACE SUPPLY, INC. | H= | P | 01/09/2019 | not ready. need mechanical contractors for new mechanical work and new gas lines being installed to addition. VERIFY MANTEL AT FINAL. | PAULO | PAULO | | H= | P | 6073741 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 01/09/2019 | fire place/vent installations and clearances ok. | PAULO | PAULO | | HV | C | 6073733 |
WESTERN FIREPLACE SUPPLY, INC. | HV | R | 01/07/2019 | not ready. need mechanical contractors for new mechanical work and new gas lines being installed to addition. | PAULO | PAULO | | HV | R | 6070498 |
CORNERSTONE PLUMBING INC | P= | C | 06/28/2019 | | JOSEPHD | JOSEPHD | | P= | C | 6248075 |
CORNERSTONE PLUMBING INC | PTO | C | 01/24/2019 | by final add 1 washer box, 2 lav, 1 toilet, 1 shower, 1 tub to scope of work, note: finished basement, aav @ basement lav, wet bar, RH master lav, cwv @ LH master lav | JOSEPHD | JOSEPHD | | PTO | C | 6086865 |
CORNERSTONE PLUMBING INC | PB | C | 10/11/2018 | Attach electrical and heating permits to building permit, test OK, basement fixtures only to lift station | SHANEN | SHANEN | | PB | C | 5991977 |
WESTERN FIREPLACE SUPPLY, INC. | XMS | T | 01/15/2019 | PAID (REC#1569701): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised calculations and design | JUSTINC | JUSTINC | | XMS | T | 6079042 |