WELLS & WEST GENERAL CONTRACTORS, INC. | B= | C | 10/01/2018 | state electrical and plumbing final certificates received / final OK pending other finals | DANE | DANE | | B= | C | 5981139 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 08/29/2018 | state electrical certification provided states that the final is only partial complete and not completed / engineer observations for welding and bolting and mono coat on file -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): NIELSEN MECHANICAL CONTRACTORS, INC. Mechanical Final Inspection is not Completed yet. | DANE | DANE | | B= | P | 5949063 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 08/17/2018 | state plumbing inspection paperwork on file / still need all stamped letters of observations for welding and bolting and mono coat and state electrical inspection -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): NIELSEN MECHANICAL CONTRACTORS, INC. Mechanical Final Inspection is not Completed yet. | DANE | DANE | | B= | P | 5937166 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 08/13/2018 | Still need engineer observation for heavy gauge steel that wall hangs on and for all welding, bolting, and mono coat -- Need state electrical and plumbing certificate of observations -- Building final for interior remodel OK pending heating final and all paperwork on file -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): NIELSEN MECHANICAL CONTRACTORS, INC. Mechanical Final Inspection is not Completed yet. | DAKOTAB | DAKOTAB | | B= | P | 5931908 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 07/18/2018 | soffits around folding wall between rooms 107 and 108 OK / need engineer observation for heavy gauge steel that the wall hangs on and for all welding and bolting and mono coat | DANE | DANE | | BFR | P | 5906942 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 07/10/2018 | need to patch in the mono coat at the steel beams over conference room 223 and IDP office 224 / remainder of interior light gauge framing is OK pending other roughs / still need stamped letter for all welding bolting and mono coat | DANE | DANE | | BFR | P | 5898461 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 07/03/2018 | remainder of framing on 1st level OK / framing at 2nd floor at conference room 206 OK / rebar and remesh at floor infills OK / discussed need for stamped letter of observations for welding and new mono coat | DANE | DANE | | BFR | P | 5892569 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 06/20/2018 | need to complete framing at rooms 103 and 110 on first floor and all of 2nd floor library and at 208 security kiosk / all other interior light gauge framing OK pending other roughs / need to attach mechanical permit / discussed need for state electrical and plumbing inspections / discussed accessible elements / need to fix mono coat at all beams above 1st floor at ceiling soffits and hard lids | DANE | DANE | | BFR | P | 5880554 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | C | 08/29/2018 | TEST AND BALANCE REPORT RECEIVED, SEE IMAGES. | DUSTINS | DUSTINS | | H= | C | 5949096 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | P | 07/27/2018 | PARTIAL PENDING TAB REPORT, REST OK | BENH | BENH | | H= | P | 5916927 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | P | 07/20/2018 | FIRST AND SECOND FLOOR ABOVE CEILING OK. FLEX AND DIFFUSERS OK. STILL NEED TO SEE THERMOSTATS, RELOCATED STATS TO BE AT 48" ABOVE FINISHED FLOOR. NEED TO COMPLETE KIOSK. PROVIDE TEST AND BALANCE REPORT FOR FINAL. | DUSTINS | DUSTINS | | H= | P | 5909169 |
NIELSEN MECHANICAL CONTRACTORS, INC. | HD | P | 07/02/2018 | ALL SECOND FLOOR NEW SUPPLY AIR DUCTS OK, OK TO WRAP EXCEPT FOR ROOM 224, 204 AND 205. FLEX INSTALLED. STILL NEED TO SEE SECURITY KIOSK ON SECOND FLOOR. PROVIDE TEST AND BALANCE REPORT FOR FINAL. | DUSTINS | DUSTINS | | HD | P | 5891906 |
NIELSEN MECHANICAL CONTRACTORS, INC. | HD | P | 06/26/2018 | ALL FIRST FLOOR SUPPLY AIR TRUNKS AND LATERALS OK, OK TO WRAP EXCEPT FOR 2 SUPPLY AIR ON VAV- 101 AND 1 SUPPLY AIR ON VAV- 106 STILL NEED INSTALLED. FLEX INSTALLED, NO DIFFUSERS. | DUSTINS | DUSTINS | | HD | P | 5885620 |
NIELSEN MECHANICAL CONTRACTORS, INC. | XMS | T | 08/20/2018 | PAID (REC#1528685) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised cfm at existing offices | JUSTINC | JUSTINC | | XMS | T | 5939145 |