SNIDER CUSTOM HOMES | B= | C | 04/19/2019 | | NICK | NICK | | B= | C | 6171450 |
SNIDER CUSTOM HOMES | B= | P | 12/27/2018 | Temp CO: Pending engineering ( Expires: 1/26/2019 12:00:00 AM) | RITA | RITA | | B= | P | 6063321 |
SNIDER CUSTOM HOMES | B= | P | 12/27/2018 | All items on file. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | P | 6063228 |
SNIDER CUSTOM HOMES | BFR | C | 12/27/2018 | Eng on file for framing items | NICK | NICK | | BFR | C | 6063225 |
SNIDER CUSTOM HOMES | BFD | C | 12/27/2018 | Eng observation on file | NICK | NICK | | BFD | C | 6063223 |
SNIDER CUSTOM HOMES | BFN | C | 12/27/2018 | Foundation design on file / Eng observation on file | NICK | NICK | | BFN | C | 6063222 |
SNIDER CUSTOM HOMES | BFT | C | 12/27/2018 | Open hole on file / Eng observation on file / #1500psf / Drain usable | NICK | NICK | | BFT | C | 6063221 |
SNIDER CUSTOM HOMES | B= | R | 12/26/2018 | complete bft bfn bfd bfr bin / finished basement, deck in. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DALE | DALE | | B= | R | 6063104 |
SNIDER CUSTOM HOMES | BLA | C | 10/16/2018 | | NICK | NICK | | BLA | C | 5995794 |
SNIDER CUSTOM HOMES | BFT | P | 10/10/2018 | 3rd party observation on file for footing / Letter states that no inspection done of retaining wall, will need inspection of retaining wall or 3rd party observation / Still need open hole, soils and foundation design | NICK | NICK | | BFT | P | 5991349 |
SNIDER CUSTOM HOMES | BFN | P | 10/10/2018 | 3rd party observation on file for foundation and grounding rod / Letter states that no inspection done of retaining wall, will need inspection of retaining wall or 3rd party observation / Still need open hole, soils and foundation design | NICK | NICK | | BFN | P | 5991341 |
SNIDER CUSTOM HOMES | BFR | P | 09/26/2018 | Still need to splice in new design elements or provide Eng letter stating as built OK / All other framing items completed / Still need all 3rd party for footing/foundation/drain | NICK | NICK | | BFR | P | 5977270 |
SNIDER CUSTOM HOMES | BFR | P | 09/25/2018 | Need to install lateral bracing for A2A, A3, A3A, A16 and A15 / Need to install ST22 straps at fire place location per detail A / Need to install SDS screws for bearing block of BG1 per detail 2 / Need to install HTS16 strap for BG1 / Need to splice plans or provide Eng for all new dropped framing of showers and for changes of front porch and deck frame, walked frame with design from design professional / Porch frame and deck OK / OK to insulate | NICK | NICK | | BFR | P | 5976441 |
SNIDER CUSTOM HOMES | BIN | P | 09/25/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5975015 |
SNIDER CUSTOM HOMES | BFI | P | 06/29/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFI | P | 5889534 |
SNIDER CUSTOM HOMES | BFD | P | 06/29/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFD | P | 5889533 |
SNIDER CUSTOM HOMES | BFT | P | 06/29/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5889532 |
SNIDER CUSTOM HOMES | BFN | P | 06/29/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5889531 |
H&H ELECTRICAL SERVICE | E= | C | 12/18/2018 | a/c installed | GARYL | GARYL | | E= | C | 6057226 |
H&H ELECTRICAL SERVICE | ES | C | 09/20/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter , new res. | JOHNN | JOHNN | | ES | C | 5971324 |
H&H ELECTRICAL SERVICE | ER | C | 09/19/2018 | NOTES---FINISHED BASEMENT--- | BRIAN | BRIAN | | ER | C | 5970183 |
H&H ELECTRICAL SERVICE | ES | R | 09/18/2018 | need to move meter socket up to proper height, | JOHNN | JOHNN | | ES | R | 5968085 |
H&H ELECTRICAL SERVICE | ER | R | 09/18/2018 | grd all round plastic boxes and metal fan boxes: a lot in master area and thru out house, add outlet downstairs at slider, wiring in unfinished space is not complete, -------------------------60 amp sub panel is not complete,------200 amp: rev ufer, no mcc, 1#6cu | JOHNN | JOHNN | | ER | R | 5968081 |
GOSSAGE CONSTRUCTION | H= | C | 12/18/2018 | direct vent equip, and hi/lo transfer, finished basement, a/c complete | DAVIDH | DAVIDH | | H= | C | 6057014 |
GOSSAGE CONSTRUCTION | HC | C | 09/20/2018 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5971856 |
GOSSAGE CONSTRUCTION | HRR | C | 09/20/2018 | | DAVIDH | DAVIDH | | HRR | C | 5971828 |
GOSSAGE CONSTRUCTION | HRR | P | 09/11/2018 | Furnace vent termination does not meet mfg installation instructions, see pg 26 "K" Water heater vent termination also lacks clearance to furnace (Mechanical air) see pg 8 "K". Basement fireplace vent lacks clearance to frame. Performance test by final. Note: Finished basement, a/c coil and line set, osa to return, furnace and water heater are both direct vent. | MARK | MARK | | HRR | P | 5961752 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 08/29/2018 | 10 lb test ok note 1 1/4 main 1 furn,w/h,bbq,range,and 2 fire places bbq not to exceed 56,000 | DAVIDH | DAVIDH | | HI | C | 5949967 |
B & L PLUMBING, INC. | P= | C | 12/20/2018 | Corrections made | MALYNDA | MALYNDA | | P= | C | 6060052 |
B & L PLUMBING, INC. | P= | P | 12/19/2018 | No water at kitchen sink in bedroom, rest ok. Note: RP installed | MALYNDA | MALYNDA | | P= | P | 6057550 |
B & L PLUMBING, INC. | P= | R | 12/07/2018 | no water, re- inspect all. | TAYLOR | TAYLOR | | P= | R | 6046790 |
B & L PLUMBING, INC. | PTO | C | 08/24/2018 | -by final fix kinked hot / cold @ south side bath shwr lines @ unfinished bsmnt area-, cwv @ both main level hall lavs, partial finished bsmnt (only 1 bath finishes), aav @ bar, tempering under mstr tub @ bsmnt, irrigation stub, rp @ mech room | JOHNS | JOHNS | | PTO | C | 5944772 |
B & L PLUMBING, INC. | PB | C | 07/10/2018 | | SHANEN | SHANEN | | PB | C | 5898048 |
SAVARIA USA INC. | V= | C | 12/26/2018 | ELEVATOR COMPLETE | ERIC | ERIC | | V= | C | 6062514 |