AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | B= | C | 01/30/2019 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 6092418 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | B= | P | 01/29/2019 | Building final OK pending electrical final complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection N= by WP ENGINEERING is not Completed yet, Electrical Final Inspection is not Completed yet. | NICK | NICK | | B= | P | 6090701 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BLA | C | 11/13/2018 | | NICK | NICK | | BLA | C | 6023653 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BIN | C | 10/23/2018 | | NATHAN | NATHAN | | BIN | C | 6003661 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BFR | P | 10/17/2018 | Eng on file for all post connections / All frame items completed | NICK | NICK | | BFR | P | 5997159 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BFR | R | 10/15/2018 | Need to install H2.5T for T02 truss / Need to install lateral bracing for T01B,T01A and T01 / Need to install 5 king studs for garage header / Need to install post base hardware per approved plans for crawl space / Need hardware call out for post to beam connection of crawl space / Need Eng for use of treated 2x4 post in place of beam pocket in crawl space / Need to complete dry in of roof (plumbing jacks) | NICK | NICK | | BFR | R | 5994487 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BSP | P | 09/27/2018 | 2 12" piers and reinforcement OK for front deck | NICK | NICK | | BSP | P | 5978791 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BSP | P | 09/10/2018 | Still need to inspect 2 12" piers per detail G on foundation design at front porch / All other 16" piers for front and back OK per design with 3 #4 bar | NICK | NICK | | BSP | P | 5959467 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BFN | C | 08/20/2018 | | NICK | NICK | | BFN | C | 5938908 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BFT | C | 08/20/2018 | Interior footings OK | NICK | NICK | | BFT | C | 5938905 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BFD | C | 08/10/2018 | Drain of usable space OK / Damp proof OK / Daylights to front left of house | NICK | NICK | | BFD | C | 5930472 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BFN | P | 07/30/2018 | Still need to install and inspect interior pads / All wall reinforcement OK per design / Foundation design on file | NICK | NICK | | BFN | P | 5917488 |
AMERICAN CRAFTSMAN HOMES OF WOODLAND PARK LLC | BFT | P | 07/19/2018 | No interior pads installed at time of inspection / Need foundation design for file / All exterior footings and reinforcement OK per design / Open hole on file | NICK | NICK | | BFT | P | 5908308 |
REGESTER ELECTRIC | E= | C | 01/29/2019 | | JOHNN | JOHNN | | E= | C | 6091286 |
REGESTER ELECTRIC | E= | R | 01/28/2019 | correction not made: jet tub heater needs to be bonded as stated in notes, lug on bottom of heater, call John with any questions 719-327-2949. | JOHNN | JOHNN | | E= | R | 6090450 |
REGESTER ELECTRIC | ES | C | 01/25/2019 | Residential Underground: 200-amp 3 Wire New Residence , meter is set, no action needed. | JOHNN | JOHNN | | ES | C | 6089100 |
REGESTER ELECTRIC | E= | R | 01/25/2019 | outside soffit outlets not working, need to be gfci if not already, leave ladder for next inspection/ washer needs afci/gfci cb, jet tub: need 2 gang plate, bond motor and heater to #8 solid cu to EGC in outlet box/ mount inter system bond terminal. | JOHNN | JOHNN | | E= | R | 6089097 |
REGESTER ELECTRIC | EUG | C | 10/30/2018 | 4/0 al,4w | JOHNN | JOHNN | | EUG | C | 6010846 |
REGESTER ELECTRIC | ER | C | 10/11/2018 | may need to move light in master closet due to shelf lay out, check on final---------------------------------notes: ir ufer, no mcc, no cv, | JOHNN | JOHNN | | ER | C | 5992383 |
A&R MECHANICAL, INC. | H= | C | 01/16/2019 | HIGH/LOW TRANSFER IN MECH RM ,DIRECT VENT FURN, NO A/C,CONDITIONED CRAWLER | DAVIDH | DAVIDH | | H= | C | 6079880 |
A&R MECHANICAL, INC. | HC | C | 10/11/2018 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5992760 |
A&R MECHANICAL, INC. | HI | C | 10/11/2018 | corrections made | DAVIDH | DAVIDH | | HI | C | 5992757 |
A&R MECHANICAL, INC. | HI | P | 10/11/2018 | needs ps-II dug down deeper per manufacture send pictures note 10 lb test ok note 1 1/4" main,1 furn,w/h,dryer, c/t and firepit | DAVIDH | DAVIDH | | HI | P | 5991941 |
A&R MECHANICAL, INC. | HRR | C | 10/11/2018 | conditioned crawler , 6"osa, no a/c | DAVIDH | DAVIDH | | HRR | C | 5991935 |
HARDERS PLUMBING & HEATING | P= | C | 01/16/2019 | note: no irrigation | JOSEPHD | JOSEPHD | | P= | C | 6079913 |
HARDERS PLUMBING & HEATING | PTO | C | 09/26/2018 | VTR, no irrigation, | SHANEN | SHANEN | | PTO | C | 5977422 |