TUSCANY HOMES LLC | B= | C | 06/18/2019 | | DALE | DALE | | B= | C | 6235683 |
TUSCANY HOMES LLC | B= | P | 05/24/2019 | Temp CO: Temp CO: Pending building final ( Expires: 6/23/2019 12:00:00 AM) | MATTHEWM | MATTHEWM | | B= | P | 6209632 |
TUSCANY HOMES LLC | B= | P | 05/23/2019 | exterior stairs behind garage from TV room have been partially removed and need to be poured back to verify that newly installed guards and hand rails are correct with the new stairs / address has been attached to the garage corner and is OK -- Schedule a new Building Final when above items are complete. | DANE | DANE | | B= | P | 6208526 |
TUSCANY HOMES LLC | B= | P | 04/26/2019 | Temp CO: waiting for building final ( Expires: 5/26/2019 12:00:00 AM) | RITA | RITA | | B= | P | 6179323 |
TUSCANY HOMES LLC | B= | P | 04/25/2019 | Need to post address on house, follow PPRBC addressing guidelines - Missing handrail, gaurdrail, fall protection at basement TV room walkout external stairs - Rear covered patio - Rear deck - Rear upper deck - Finished basement - AC installed x2 -- Schedule a new Building Final when above items are complete. | TIMOTHYS | TIMOTHYS | | B= | P | 6177806 |
TUSCANY HOMES LLC | B= | R | 04/24/2019 | no access to site - no gate code given in comments and no guard at guard shack at main gate - made physical call to call ahead number but no answer so could not get a gate code - waited at shack for approximately 5 minutes for guard before leaving / need to provide gate code with every inspection | DANE | DANE | | B= | R | 6176596 |
TUSCANY HOMES LLC | BLA | C | 01/22/2019 | | DALE | DALE | | BLA | C | 6085184 |
TUSCANY HOMES LLC | BLA | P | 01/16/2019 | Need to seal all penetration through building paper | TIMOTHYS | TIMOTHYS | | BLA | P | 6080158 |
TUSCANY HOMES LLC | BFR | C | 01/16/2019 | Received engineers letter for added door at balcony upper level | TIMOTHYS | TIMOTHYS | | BFR | C | 6080157 |
TUSCANY HOMES LLC | BLA | R | 01/15/2019 | weep screed on north end from gas meter to patio does not have holes in it to let water escape / rest of lath OK / need to complete BFR | DANE | DANE | | BLA | R | 6078785 |
TUSCANY HOMES LLC | BFR | T | 12/17/2018 | PAID (REC#1569473) Still need letter for added door at upper level hallway - Other frame corrections covered by insulation | TIMOTHYS | TIMOTHYS | | BFR | T | 6054906 |
TUSCANY HOMES LLC | BSP | P | 12/17/2018 | Engineers letter for portal frame on file | TIMOTHYS | TIMOTHYS | | BSP | P | 6054424 |
TUSCANY HOMES LLC | BIN | P | 12/13/2018 | Insulation items complete // Partial pending clear frame | JEREMYA | JEREMYA | | BIN | P | 6052042 |
TUSCANY HOMES LLC | BIN | P | 12/12/2018 | Missing air barrier behind fireplace on main level // Missing air barrier at shower seat // Missing air barrier behind tub in basement // Fix areas that electricians tore up to install boxes // Unable to locate engineer letter on site to complete framing items. Suggest electronic upload | JEREMYA | JEREMYA | | BIN | P | 6050604 |
TUSCANY HOMES LLC | BFR | P | 12/07/2018 | Still missing rain collar on B vent roof jack to complete dry-in -- Still need engineer letter for door added at upper level balcony -- Missing gusset on M5 truss at exterior wall at upper level hallway -- Other items from previous inspection corrected | DAKOTAB | DAKOTAB | | BFR | P | 6046241 |
TUSCANY HOMES LLC | BFR | R | 12/06/2018 | Missing anchor at plate break back of 3rd car garage - Missing rain collar on B vent roof jacks to complete dry in - Need engineers letter or splice for door added upper level balcony - Steel column at mech room and hallway not centered on beam, side loading - NW basement bedroom beam pocket has wood block - Wood blocks in beam pockets over basement bathroom - Received engineers repair detail for cut truss at E13 - Received engineers letter for narrow brace wall issue - Upper floor, main floor, and basement framing inspected - Still need to inspect trusses | TIMOTHYS | TIMOTHYS | | BFR | R | 6044935 |
TUSCANY HOMES LLC | BFR | R | 11/30/2018 | Inspection stopped too many items to list - Walked with framer - Provide gate code with inspection requests | TIMOTHYS | TIMOTHYS | | BFR | R | 6040073 |
TUSCANY HOMES LLC | BFR | T | 11/26/2018 | PAID (REC#1559861) Inspection stopped after garage and upper level trusses inspected - Too many items / NOTE: door at loft to patio not on approved plans | JUSTINL | JUSTINL | | BFR | T | 6034409 |
TUSCANY HOMES LLC | BTR | C | 11/20/2018 | Battens, flashing, and underlayment OK | PARKER | PARKER | | BTR | C | 6031320 |
TUSCANY HOMES LLC | BSP | R | 11/06/2018 | Narrow brace walls require (2) anchors per side per detail - Narrow brace walls do not meet the minimum width requirements in detail | TIMOTHYS | TIMOTHYS | | BSP | R | 6017652 |
TUSCANY HOMES LLC | BFD | C | 08/02/2018 | photo of drain connection on file | DANE | DANE | | BFD | C | 5921426 |
TUSCANY HOMES LLC | BFD | P | 08/01/2018 | engineer letter for floor drain at landing of exterior stairs on file / still need confirmation of drain connection to under drain via photo | DANE | DANE | | BFD | P | 5920015 |
TUSCANY HOMES LLC | BFD | P | 07/23/2018 | usable drain OK pending verification of connection to underdrain via photo or reinspection | DANE | DANE | | BFD | P | 5911470 |
TUSCANY HOMES LLC | BFN | C | 07/23/2018 | Engineers observation Letter on file / Eufer noted / Foundation design on file / Soils report on file / 2400 - usable - 5% | DANE | DANE | | BFN | C | 5910315 |
TUSCANY HOMES LLC | BFT | C | 07/23/2018 | Engineers observation Letter on file | DANE | DANE | | BFT | C | 5910308 |
TUSCANY HOMES LLC | BFT | P | 07/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5900362 |
TUSCANY HOMES LLC | BFN | P | 07/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5900361 |
MEYER ELECTRIC | E= | C | 04/23/2019 | | BRET | BRET | | E= | C | 6174547 |
MEYER ELECTRIC | E= | R | 04/22/2019 | cannot have exterior receptacle on small appliance circuit | BRET | BRET | | E= | R | 6174468 |
MEYER ELECTRIC | E= | R | 04/19/2019 | need gate code | BRET | BRET | | E= | R | 6171348 |
MEYER ELECTRIC | E= | R | 04/18/2019 | strap riser, missing receptacle on dining room patio, no power to gfci on main patio, label a/c disconnect , note lighting box over master tub blanked off, 35 and 45 amp a/c installed | BRET | BRET | | E= | R | 6170356 |
MEYER ELECTRIC | ES | C | 02/13/2019 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | BRET | BRET | | ES | C | 6106077 |
MEYER ELECTRIC | ES | R | 11/29/2018 | Need by pass in meter section / | ROB | ROB | | ES | R | 6038643 |
MEYER ELECTRIC | ES | R | 11/16/2018 | add main disconnect at meter, 4/0-4/0-2/0 cannot run thru home unprotected. relocate ufer and separate grounds and neutrals in basement panel | BRET | BRET | | ES | R | 6028306 |
MEYER ELECTRIC | ER | C | 11/16/2018 | #2 al, garage sub, no mcc, no vac, #6 al a/c double oven | BRET | BRET | | ER | C | 6028299 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 04/24/2019 | DUCT LEAK REPORT ATTACHED, SEE IMAGES | BENH | BENH | | H= | C | 6175949 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 04/23/2019 | STILL NEED DUCT LEAKAGE REPORT FOR UPPER LEVEL FURNACE. NOTE: FINISHED BASEMENT, 7" HIGH COMBUSTION AIR FOR UPPER LEVEL FURNACE, HIGH/LOW GRILLES TO MECHANICAL ROOM, 2- OUTSIDE AIR TO FURNACE RETURN, 2- A/C INSTALLED. | DUSTINS | DUSTINS | | H= | P | 6174781 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 04/19/2019 | NEED DUCT LEAKAGE REPORT FOR UPPER LEVEL FURNACE. UPPER LEVEL FURNACE LACKS COMBUSTION AIR. NEED FIREPLACE MANUALS TO CHECK FOR MANTEL CLEARANCES. WATER HEATER B-VENT LACKS CLEARANCE TO COMBUSTIBLES IN MECHANICAL ROOM. HIGH/LOW GRILLES TO MECHANICAL ROOM ARE UNDERSIZED FOR 232K BTU OF APPLIANCES IN MECHANICAL ROOM. IS THE SECOND A/C IN BASEMENT BEING INSTALLED? STOPPED INSPECTION, CONTRACTOR TO WALK JOB BEFORE CALLING FOR NEXT INSPECTION. RE-INSPECT ALL. NOTE: FINISHED BASEMENT, 2- OUTSIDE AIR TO FURNACE RETURN, HIGH/LOW GRILLES TO MECHANICAL ROOM, 2- A/C INSTALLED. | DUSTINS | DUSTINS | | H= | R | 6171493 |
WHITE BROS CUSTOM PLUMBING & HEATING | HC | C | 11/16/2018 | RELEASE METER | DUSTINS | DUSTINS | | HC | C | 6028188 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | C | 11/16/2018 | 10 LB TEST OK. 1 1/2" MAIN. 3- FURNACE, 2- WATER HEATER, 1- RANGE, 2- FIREPLACE, 1- BBQ. | DUSTINS | DUSTINS | | HI | C | 6028187 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | L | 11/12/2018 | No address posted. | JEFFL | JEFFL | | HI | L | 6022823 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 11/07/2018 | CORRECTIONS MADE, SEE IMAGES | BENH | BENH | | HRR | C | 6018149 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 11/06/2018 | HEAT RUN IS STILL COVERED BY FRAMING NEXT TO FRONT DOOR ON MAIN LEVEL. DUCT LEAKAGE REPORT BY FINAL. NOTE: FINISHED BASEMENT, 2- OUTSIDE AIR TO FURNACE RETURN, 2- A/C ROUGH COIL AND LINE SET. | DUSTINS | DUSTINS | | HRR | P | 6017330 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 11/05/2018 | Two supply runs need lowered to finished ceiling height in basement. Heat run is covered by framing next to front door at main level. **Duct leakage report needed by final. Notes-- AC rough line set x 2. Finished basement. Outside air to return x 2. | JEFFL | JEFFL | | HRR | P | 6015930 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 10/23/2018 | NOT READY: RE-INSPECT ALL. Basement fireplace not yet installed. To be a 7' serving basement bathroom 2 from 14x8 trunk, 6" installed. Drop supply in basement bedroom 1 to finished ceiling height. Complete bath exhaust and repair duct serving basement bathroom behind bar. Provide bath exhaust to basement bathroom by bedroom 1. Possibly more. BY FINAL: Provide 5" supply to mechanical room. | RANDYB | RANDYB | | HRR | R | 6003578 |
WHITE BROS CUSTOM PLUMBING & HEATING | P= | C | 04/16/2019 | pvb ok, finished bsmnt | JOHNS | JOHNS | | P= | C | 6167531 |
WHITE BROS CUSTOM PLUMBING & HEATING | PTO | C | 11/16/2018 | | TAYLOR | TAYLOR | | PTO | C | 6027736 |
WHITE BROS CUSTOM PLUMBING & HEATING | PTO | P | 11/12/2018 | still missing nail protection in wall for kitchen drain at basement, rest ok. | TAYLOR | TAYLOR | | PTO | P | 6022852 |
WHITE BROS CUSTOM PLUMBING & HEATING | PTO | P | 10/25/2018 | need freeze protection in garage for trap, lost test DWV at master and main floor bath, missing nail protection basement and master lavs, drain for kitchen, rest ok, finished basement, aav's at laundry and island sinks. | TAYLOR | TAYLOR | | PTO | P | 6005755 |
WHITE BROS CUSTOM PLUMBING & HEATING | PB | C | 07/31/2018 | | TAYLOR | TAYLOR | | PB | C | 5918812 |
TUSCANY HOMES LLC | XBS | P | 11/29/2018 | PLAN SPLICE: (No Fee) by: SHELLEY for Construction: Architectural sheets to match previous splice for upper level balcony | SHELLEY | SHELLEY | | XBS | P | 6038485 |
TUSCANY HOMES LLC | XBS | T | 11/20/2018 | PAID (REC#1557868) PLAN SPLICE FEE: $50 by: DANM for Construction: Couple of upper floor framing revisions | DANM | DANM | | XBS | T | 6031411 |