RAY - ECCHER SERVICES, LLC | B= | C | 07/05/2019 | insignia # 35788 / serial # 17-M 33690 | DALE | DALE | | B= | C | 6254280 |
RAY - ECCHER SERVICES, LLC | BSP | T | 07/01/2019 | PAID (REC#1610642) ADDITIONAL PLAN REVIEW TIME: $50 From: MICHAELA Add stairs to deck | MICHAELA | MICHAELA | | BSP | T | 6249511 |
RAY - ECCHER SERVICES, LLC | B= | R | 06/28/2019 | missing numeric address posted in permanent manner at private drive and public street / missing address posted on home / penetrations in garage lid / need permit for main entry deck at front door attached to home - completed prior to RBD inspections / missing all gutters and downspouts | BRIANB | BRIANB | | B= | R | 6247766 |
RAY - ECCHER SERVICES, LLC | BIN | C | 03/08/2019 | | DALE | DALE | | BIN | C | 6128492 |
RAY - ECCHER SERVICES, LLC | BFR | C | 03/08/2019 | | DALE | DALE | | BFR | C | 6128490 |
RAY - ECCHER SERVICES, LLC | BFR | P | 03/05/2019 | need to sheath inside of garage door headers / block to of garage door brackets / need anchor bolt at splice at rear | DALE | DALE | | BFR | P | 6124623 |
RAY - ECCHER SERVICES, LLC | BFD | C | 11/27/2018 | drain observation letter received at office | BRIANB | BRIANB | | BFD | C | 6034626 |
RAY - ECCHER SERVICES, LLC | BTD | P | 11/20/2018 | Complete perimeter drain inspection / Basement frame inspection not done at this time / Tie down inspection only- perimeter nailing okay / Addition marriage wall missing screws / Hinge truss P1039506 missing 2 out of 3 lateral bracing each section / Floor marriage wall okay / 2 main marriage walls okay | SHAUN | SHAUN | | BTD | P | 6031646 |
RAY - ECCHER SERVICES, LLC | BTD | R | 11/02/2018 | inspection stopped - too many items / could not access all mate line components / need to complete drain inspection - soils letter requires perimeter drain around all habitable or storage space | BRIANB | BRIANB | | BTD | R | 6014391 |
RAY - ECCHER SERVICES, LLC | BVM | C | 11/02/2018 | unable to verify serial number and hud # / picture of data sheet uploaded to permit / updated 11/5 - after further review all required paper work is on file / changed inspection from partial to complete | BRIANB | BRIANB | | BVM | C | 6014381 |
RAY - ECCHER SERVICES, LLC | BFN | C | 08/29/2018 | Formwork & reinforcement for foundation walls (including attached retaining wall) OK per plans / ufer observed in foundation wall approx 3' north of retaining wall intersection / plans reviewed onsite | RICHB | RICHB | | BFN | C | 5949459 |
RAY - ECCHER SERVICES, LLC | BFT | C | 08/23/2018 | Third party observations on file / previous reinforcement clearance issues resolved / training with Chuck | RICHB | RICHB | | BFT | C | 5944245 |
RAY - ECCHER SERVICES, LLC | BFT | R | 08/22/2018 | Stamped soils report, open hole and densities received / Floating framing required / overexcavation drain and foundation drain required / 10% surface grading / 2000psf. Rebar mat to be placed in all required footing locations and have minimum coverage clearances to grade as per plan / Training with Chuck. | RICHB | RICHB | | BFT | R | 5942554 |
RAY - ECCHER SERVICES, LLC | E= | C | 06/17/2019 | | CRAIGS | CRAIGS | | E= | C | 6233539 |
RAY - ECCHER SERVICES, LLC | E= | R | 04/25/2019 | Need KO seals in panel / Label panel correctly / Need light and recpt. installed outside on west end / Missing 3 j box covers on garage level/ Need to check overhead door openers / Smoke alarm on lower level no working / Need access doors installed for NM plug connectors / | ROB | ROB | | E= | R | 6178268 |
RAY - ECCHER SERVICES, LLC | ES | C | 04/25/2019 | Residential Underground: 200 amp service complete / No action required / | ROB | ROB | | ES | C | 6178217 |
SPRINGS FAMILY ELECTRIC | ER | C | 03/04/2019 | corrections made as requested | CHIPO | CHIPO | | ER | C | 6123567 |
SPRINGS FAMILY ELECTRIC | ER | R | 03/01/2019 | install accesses directly below all the splices ---- there is an n/m cable run under a floor joist north west side of the garage | CRAIGS | CRAIGS | | ER | R | 6121769 |
SPRINGS FAMILY ELECTRIC | ER | L | 02/28/2019 | called @ 4:00 ---- locked @ 4:30 | CRAIGS | CRAIGS | | ER | L | 6120789 |
SPRINGS FAMILY ELECTRIC | ES | P | 12/28/2018 | Residential Underground: 200 amp 3/w new res --- going from over head to underground - OK to set mete and energize --- note to the inspector ----contractor assures me the meter will be between 5 and 6' by final --- uffer needs to be accessible by final | CRAIGS | CRAIGS | | ES | P | 6064642 |
SPRINGS FAMILY ELECTRIC | ER | R | 12/27/2018 | cant use in wall splices , this application does no fit the requirements ---- use mud ring to make the 4 square box flush after sheet rock ----- complete re inspection required , please call service in at the same time if its ready ---- up stairs was done at the factory | CRAIGS | CRAIGS | | ER | R | 6063478 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 05/03/2019 | Note: Furnace is direct vent, electric water heater, no a/c, no outside air to the return. This is a manufactured home. | MARK | MARK | | H= | C | 6187031 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 02/19/2019 | RELEASE METER | MARK | MARK | | HC | C | 6111092 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 02/19/2019 | Rough is good. | MARK | MARK | | HRR | C | 6111085 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 01/23/2019 | Need to make connections, seal, support ducting. Note: Furnace is direct vent, water heater is electric. | MARK | MARK | | HRR | P | 6085690 |
KROME GAS AND PLUMBING CO., INC. | HI | C | 10/18/2018 | 10 LB TEST OK. 3/4" MAIN, 1 FURNACE. | KYLEW | KYLEW | | HI | C | 5999517 |
KROME GAS AND PLUMBING CO., INC. | P= | C | 03/01/2019 | | DANR | DANR | | P= | C | 6121865 |
KROME GAS AND PLUMBING CO., INC. | PTO | C | 03/01/2019 | Corrections made. | DANR | DANR | | PTO | C | 6121864 |
KROME GAS AND PLUMBING CO., INC. | PTO | P | 02/28/2019 | Freeze protection garage, terminate water heater pan drain per code, rest ok. Note: electric water heater, potable water certificate in images. | DANR | DANR | | PTO | P | 6120131 |
KROME GAS AND PLUMBING CO., INC. | PWO | C | 12/12/2018 | | DANR | DANR | | PWO | C | 6050944 |
KROME GAS AND PLUMBING CO., INC. | PWO | P | 11/26/2018 | Pot hole and expose pipe by house, connect at well, need 46" ground coverage minimum by well, rest ok. Note: need potable water certificate by final. | DANR | DANR | | PWO | P | 6033955 |
KROME GAS AND PLUMBING CO., INC. | PTO | P | 10/26/2018 | New main for stubs ok, Note: Need PWO permit and inspection (potable water cert.), need test on water connections and all dwv connection before garage ceiling covered. | DANR | DANR | | PTO | P | 6007630 |
FAIRWAY PLUMBING & HEATING, INC. | PB | C | 09/07/2018 | Ok. Note: need pwo inspection, and potable water cert by final. | DANR | DANR | | PB | C | 5958311 |