CUSTOM DREAM DESIGN LLC | B= | C | 08/05/2019 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 6289187 |
CUSTOM DREAM DESIGN LLC | B= | P | 07/16/2019 | crawl space, no deck. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819). | DALE | DALE | | B= | P | 6265708 |
CUSTOM DREAM DESIGN LLC | BFR | C | 07/16/2019 | | DALE | DALE | | BFR | C | 6265706 |
CUSTOM DREAM DESIGN LLC | BIN | C | 01/23/2019 | Training with Ian - Post address - Insulation ok | TIMOTHYS | TIMOTHYS | | BIN | C | 6085480 |
CUSTOM DREAM DESIGN LLC | BFR | P | 01/11/2019 | foam and fire block incomplete throughout / OK to insulate | LONNYS | LONNYS | | BFR | P | 6076329 |
CUSTOM DREAM DESIGN LLC | BFN | C | 10/22/2018 | foundation design received | DALE | DALE | | BFN | C | 6001149 |
CUSTOM DREAM DESIGN LLC | BFN | P | 10/15/2018 | still need detail page for foundation design / damp proofing verified | LONNYS | LONNYS | | BFN | P | 5994325 |
CUSTOM DREAM DESIGN LLC | BFN | P | 10/15/2018 | need detail page of foundation design / Engineers observation Letter on file / Eufer OK / Soils report on file / open hoe on file / 1000 psf / no drain required | DALE | DALE | | BFN | P | 5994142 |
CUSTOM DREAM DESIGN LLC | BFT | C | 10/15/2018 | Engineers observation Letter on file / | DALE | DALE | | BFT | C | 5994134 |
CUSTOM DREAM DESIGN LLC | BFN | R | 10/11/2018 | Paperwork not uploaded per contractors notes / Foundation poured prior to inspection | SHAUN | SHAUN | | BFN | R | 5991726 |
CUSTOM DREAM DESIGN LLC | BFN | R | 10/08/2018 | need all paperwork from eng. to complete bft bfn | DALE | DALE | | BFN | R | 5988778 |
CUSTOM DREAM DESIGN LLC | BFT | P | 10/03/2018 | need all paperwork to complete bft | DALE | DALE | | BFT | P | 5984544 |
CUSTOM DREAM DESIGN LLC | BFN | P | 10/03/2018 | need all paperwork to complete bfn | DALE | DALE | | BFN | P | 5984542 |
CUSTOM DREAM DESIGN LLC | BFT | R | 09/19/2018 | canceled by contractor | DALE | DALE | | BFT | R | 5969655 |
COLOWATT ELECTRIC LLC | E= | C | 04/15/2019 | | TOMC | TOMC | | E= | C | 6166338 |
COLOWATT ELECTRIC LLC | ES | C | 01/08/2019 | Residential Underground: 125 - amp 3 Wire New Residence ok to set meter / | CRAIG | CRAIG | | ES | C | 6072355 |
COLOWATT ELECTRIC LLC | ER | C | 01/08/2019 | Non Irreversible UFER connection / No Cent Vac / Crawl space ------- no mcc 10/3 8/3 al | CRAIG | CRAIG | | ER | C | 6072345 |
COLOWATT ELECTRIC LLC | EUG | C | 01/08/2019 | 3/w 2/0 al | CRAIG | CRAIG | | EUG | C | 6072343 |
NOACH HEATING, INC. | H= | C | 05/01/2019 | | KYLEW | KYLEW | | H= | C | 6183531 |
NOACH HEATING, INC. | H= | P | 04/23/2019 | NEED 1" TO SHEET ROCK AT WATER HEATER FLUE - COULD NOT LOCATE CRAWLSPACE SUPPLY NOTES: LOUVERED DOOR TO WATER HEATER AND INDIRECT FURNACE | JERRYF | JERRYF | | H= | P | 6175873 |
NOACH HEATING, INC. | H= | R | 04/19/2019 | All doors locked. Screen still needs to be removed from dryer exhaust. | RANDYB | RANDYB | | H= | R | 6171281 |
ERNST ENTERPRISES | HC | C | 01/10/2019 | RELEASE METER | BILLS | BILLS | | HC | C | 6074191 |
ERNST ENTERPRISES | HI | C | 01/10/2019 | 10LB TEST OK | BILLS | BILLS | | HI | C | 6074183 |
ERNST ENTERPRISES | HI | P | 01/09/2019 | LOW TEST (7.5 PSI). 1" MAIN, 1 FURNACE, 1 WATER HEATER. | KYLEW | KYLEW | | HI | P | 6072845 |
NOACH HEATING, INC. | HRR | C | 01/08/2019 | BY FINAL: CONDITION CRAWLSPACE, CONFIRM WATER HEATER VENT CONNECTIONS IN MECHANICAL CLOSET, REMOVE SCREEN FROM DRYER EXHAUST TERMINATION CAP. NOTE: NO A/C, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | HRR | C | 6071247 |
DMB PLUMBING SERVICES INC. | P= | C | 05/03/2019 | correction made | TED | TED | | P= | C | 6187368 |
DMB PLUMBING SERVICES INC. | P= | R | 05/02/2019 | install trap guards and open crawlspace | TED | TED | | P= | R | 6185518 |
DMB PLUMBING SERVICES INC. | PTO | C | 12/13/2018 | crawlspace, water and drain under footer, no sprinkler stub | TED | TED | | PTO | C | 6052629 |