ROCKWOOD HOMES, LLC | B= | C | 08/20/2019 | All other required Final inspections are complete. (This is a computer generated result) | SCOTTS | SCOTTS | | B= | C | 6307804 |
ROCKWOOD HOMES, LLC | B= | P | 08/19/2019 | finished basement/rear deck. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | SCOTTS | SCOTTS | | B= | P | 6305424 |
ROCKWOOD HOMES, LLC | BIN | C | 04/23/2019 | | SCOTTS | SCOTTS | | BIN | C | 6175188 |
ROCKWOOD HOMES, LLC | BFR | C | 04/23/2019 | | SCOTTS | SCOTTS | | BFR | C | 6175185 |
ROCKWOOD HOMES, LLC | BFR | P | 04/19/2019 | missing H2.5 ee of A05 and A13 | SCOTTS | SCOTTS | | BFR | P | 6172235 |
ROCKWOOD HOMES, LLC | BFD | C | 04/19/2019 | drain observation on file | SCOTTS | SCOTTS | | BFD | C | 6171210 |
ROCKWOOD HOMES, LLC | BFN | C | 04/19/2019 | foundation observation on file | SCOTTS | SCOTTS | | BFN | C | 6171209 |
ROCKWOOD HOMES, LLC | BSP | P | 04/19/2019 | foundation design on file | SCOTTS | SCOTTS | | BSP | P | 6171208 |
ROCKWOOD HOMES, LLC | BSP | P | 04/19/2019 | soils report on file | SCOTTS | SCOTTS | | BSP | P | 6171207 |
ROCKWOOD HOMES, LLC | BSP | P | 04/19/2019 | open ex on file/2400 psf/grade 5%/drain useable/float 1 1/2" | SCOTTS | SCOTTS | | BSP | P | 6171206 |
ROCKWOOD HOMES, LLC | BSP | P | 04/19/2019 | drain tie in on file | SCOTTS | SCOTTS | | BSP | P | 6171203 |
ROCKWOOD HOMES, LLC | BFT | P | 04/15/2019 | pending soils/open ex -- footing observation on file | SCOTTS | SCOTTS | | BFT | P | 6165308 |
ROCKWOOD HOMES, LLC | BLA | C | 02/27/2019 | | BRIANB | BRIANB | | BLA | C | 6119465 |
ROCKWOOD HOMES, LLC | BSP | P | 02/04/2019 | deck framing ok | SCOTTS | SCOTTS | | BSP | P | 6096881 |
ROCKWOOD HOMES, LLC | BSP | P | 02/04/2019 | deck letter on file | SCOTTS | SCOTTS | | BSP | P | 6096220 |
ROCKWOOD HOMES, LLC | BSP | P | 12/19/2018 | stamped letter on file for nail substitution | SCOTTS | SCOTTS | | BSP | P | 6057346 |
ROCKWOOD HOMES, LLC | BSP | P | 12/18/2018 | porch/patio framing is per plan -- portal framing is per plan | SCOTTS | SCOTTS | | BSP | P | 6056992 |
ROCKWOOD HOMES, LLC | BSP | P | 12/18/2018 | fire resistant gable end drywall attachment inspection/fastening per field copy of letter for nail substitution per plan/still need stamped letter | SCOTTS | SCOTTS | | BSP | P | 6056816 |
ROCKWOOD HOMES, LLC | BSP | R | 12/18/2018 | letter on file for nail substitute per listing/update/ provide stamped letter | SCOTTS | SCOTTS | | BSP | R | 6055889 |
ROCKWOOD HOMES, LLC | BSP | P | 11/29/2018 | fire resistance wall from foundation to bottom of trusses complete per GA WP 3510 | SCOTTS | SCOTTS | | BSP | P | 6038198 |
ROCKWOOD HOMES, LLC | BFD | P | 11/19/2018 | tie in to underdrain complete -- verification on file / pending all paper work to complete foundation and drain inspections | BRIANB | BRIANB | | BFD | P | 6028890 |
ROCKWOOD HOMES, LLC | BFD | P | 09/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFD | P | 5963267 |
ROCKWOOD HOMES, LLC | BFT | P | 09/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5963266 |
ROCKWOOD HOMES, LLC | BFN | P | 09/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5963265 |
MEYER ELECTRIC | E= | C | 08/16/2019 | | RANDY | RANDY | | E= | C | 6303804 |
MEYER ELECTRIC | E= | R | 08/15/2019 | Grade level gfci in back must be covered / No AC installed / | ROB | ROB | | E= | R | 6301969 |
MEYER ELECTRIC | ES | C | 03/22/2019 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | JOSEPH | JOSEPH | | ES | C | 6140759 |
MEYER ELECTRIC | ES | R | 03/08/2019 | # 4 solid copper from ufer should terminate to service neutral terminal strip. / Neutral conductors cannot be landed on equipment grounding terminal strip only. (You can't use only the panel enclosure to conduct neutral current). / Rest of 200 amp service is good. | JOSEPH | JOSEPH | | ES | R | 6127935 |
MEYER ELECTRIC | ER | C | 03/08/2019 | Finished basement / UFER is ir / 6/3 al to floated sub / 6/3 al to range / no vac | JOSEPH | JOSEPH | | ER | C | 6127880 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 08/13/2019 | NOTES: Finished basement. Outside air to furnace return. Louver door to mechanical room. A/C Rough coil and line-set. | BILLS | BILLS | | H= | C | 6299347 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 07/09/2019 | Status unchanged. | RANDYB | RANDYB | | H= | R | 6257338 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/08/2019 | Gas to fireplace is not connected. Missing supply within basement bedroom. Water heater vent connector lacks clearance to PEX line. NOTES: Finished basement. Outside air to furnace return. Louver door to mechanical room. A/C Rough coil and line-set. | RANDYB | RANDYB | | H= | P | 6256305 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/03/2019 | RELEASE METER | MARK | MARK | | HC | C | 6153101 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/03/2019 | Vent has been corrected. | MARK | MARK | | HRR | C | 6153100 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/02/2019 | Furnace vent connector is missing an increaser/reducer vent adapter at the furnace end. 5" vent connector to 4" fan outlet. Note: Finished basement with a/c coil and line set, outside air to return. | MARK | MARK | | HRR | P | 6152008 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 03/27/2019 | RE-INSPECT ALL. Too many items to list. Not ready. | RANDYB | RANDYB | | HRR | R | 6146892 |
CORNERSTONE PLUMBING INC | HI | C | 01/23/2019 | 10 LB TEST OK , 1 INCH MAIN , 1 FURNACE , 1 WATER HEATER, 1 RANGE , 1 FIRE PLACE | ANDREWP | ANDREWP | | HI | C | 6085982 |
CORNERSTONE PLUMBING INC | P= | C | 08/14/2019 | correction made | TED | TED | | P= | C | 6300539 |
CORNERSTONE PLUMBING INC | P= | P | 08/13/2019 | Secure expansion tank, and vertical pex at recirc line. Pex line does not have minimal clearance from water heater vent. Rest OK. Note: No irrigation. | SAMH | SAMH | | P= | P | 6298147 |
CORNERSTONE PLUMBING INC | PTO+ | C | 04/15/2019 | AAV at lav. | SAMH | SAMH | | PTO+ | C | 6165484 |
CORNERSTONE PLUMBING INC | PTO | C | 01/17/2019 | VTR (1), Unfinished basement, No sprinkler. | SAMH | SAMH | | PTO | C | 6081715 |
CORNERSTONE PLUMBING INC | PB | C | 11/19/2018 | ok, water under footer | TED | TED | | PB | C | 6029340 |
CORNERSTONE PLUMBING INC | PB | L | 11/16/2018 | Field Cancelled | MALYNDA | MALYNDA | | PB | L | 6027581 |