SHARP GENERAL CONTRACTORS, INC | B= | C | 01/16/2019 | All other required Final inspections are complete. (This is a computer generated result) | RICHB | RICHB | | B= | C | 6079312 |
SHARP GENERAL CONTRACTORS, INC | B= | P | 01/09/2019 | Interior Finish OK pending other Finals / sink height in Men's Restroom has been corrected (see P= comments). Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection HD= by HEALTHDEPT is not Completed yet, AIR TECH MECHANICAL INC Mechanical Final Inspection is not Completed yet, ELECTRIC TECH INC. Electrical Final Inspection is not Completed yet, LANDMARK PLUMBING & HEATING, INC. Mechanical Final Inspection is not Completed yet, LANDMARK PLUMBING & HEATING, INC. Plumbing Final Inspection is not Completed yet. | RICHB | RICHB | | B= | P | 6073064 |
SHARP GENERAL CONTRACTORS, INC | BFR | P | 11/05/2018 | Remainder of framing OK pending other Roughs / discussed accessible elements / discussed status of Core & Shell permit - need C&S complete prior to Finals for this permit | RICHB | RICHB | | BFR | P | 6016091 |
SHARP GENERAL CONTRACTORS, INC | BFR | P | 10/29/2018 | Partial framing - hood wall OK pending Mechanical and other Roughs / restrooms, bar and full-height wall at approx Grid 1.7 OK pending other Roughs / still need to inspect the rest of framing when ready / discussed accessible elements with Leonard (Contractor) onsite | RICHB | RICHB | | BFR | P | 6008473 |
ELECTRIC TECH INC. | E= | C | 01/11/2019 | 15 amp ef ---- 90 amp mau OK | CRAIGS | CRAIGS | | E= | C | 6076533 |
ELECTRIC TECH INC. | ER | P | 12/04/2018 | all walls complete,and bar columns, | JOHNN | JOHNN | | ER | P | 6042014 |
ELECTRIC TECH INC. | ER | P | 11/30/2018 | all ceilings in kitchen prep area | GARYL | GARYL | | ER | P | 6040192 |
ELECTRIC TECH INC. | ER | P | 11/16/2018 | all walls | GARYL | GARYL | | ER | P | 6027617 |
ELECTRIC TECH INC. | ER | P | 11/12/2018 | ALL walls EXCEPT exterrior wall with one recept, NOTE! need a splice to show what was deleted/added before final | GARYL | GARYL | | ER | P | 6023285 |
ELECTRIC TECH INC. | ER | P | 11/07/2018 | these areas only: kitchen walls, bathrooms, 1-office, | GARYL | GARYL | | ER | P | 6019370 |
ELECTRIC TECH INC. | ER | P | 10/26/2018 | HOOD wall only, both sides | GARYL | GARYL | | ER | P | 6008080 |
ELECTRIC TECH INC. | ESL | C | 10/10/2018 | | JOHNN | JOHNN | | ESL | C | 5990890 |
LANDMARK PLUMBING AND HEATING, INC. | H= | C | 01/16/2019 | | JACK | JACK | | H= | C | 6079311 |
LANDMARK PLUMBING AND HEATING, INC. | H= | P | 01/15/2019 | NEED TO CONSULT WITH PREVIOUS INSPECTOR TO GO OVER GAS SPLICE . | LIDO | LIDO | | H= | P | 6078394 |
AIRTECH MECHANICAL, INC. | H= | C | 01/11/2019 | MECHANICAL FINAL OK. | DUSTINS | DUSTINS | | H= | C | 6076538 |
AIRTECH MECHANICAL, INC. | H= | P | 01/11/2019 | TAB REPORT RECEIVED WILL NEED SITE VISIT FOR OTHER ITEMS ALREADY SET FOR TODAY | JERRYF | JERRYF | | H= | P | 6075594 |
AIRTECH MECHANICAL, INC. | H= | P | 01/10/2019 | PARTIAL PENDING THE FOLLOWING - TAB REPORT - HOOD SKIRTS INSTALLED - ALL GREASE FILTERS INSTALLED - SOMEONE NEEDS TO CLAIM ICE MAKERS AND CALL INSPECTIONS - LABEL ICE MAKER CONDENSERS ON ROOF | JERRYF | JERRYF | | H= | P | 6075367 |
LANDMARK PLUMBING AND HEATING, INC. | H= | P | 01/02/2019 | PARTIAL FINAL PENDING PLAN REVISION FOR GAS SYSTEM TO MATCH INSTALLED PER PREVIOUS NOTES NOTES: ALL REGULATORS / FINAL CONNECTIONS AND TIE DOWNS ARE COMPLETE | JERRYF | JERRYF | | H= | P | 6066825 |
AIRTECH MECHANICAL, INC. | HSP | P | 01/02/2019 | WHEN DOING GAS INSPECTION NOTICED MUA UNIT WILL NEED SAFETY RAILING INSTALLED - NOTIFIED SCOTT WITH AIR TECH | JERRYF | JERRYF | | HSP | P | 6066824 |
LANDMARK PLUMBING AND HEATING, INC. | HV | C | 01/02/2019 | WATER HEATER VENT OK | JERRYF | JERRYF | | HV | C | 6066819 |
LANDMARK PLUMBING AND HEATING, INC. | HC | C | 11/02/2018 | OK FOR 2# METER SET | JERRYF | JERRYF | | HC | C | 6014608 |
LANDMARK PLUMBING AND HEATING, INC. | HI | C | 11/02/2018 | PRESSURE TEST AND PIPING OK - NEED PLAN REVISED TO MATCH INSTALLED - ALL LABELS ARE COMPLETE - STILL NEED ALL REGULATORS AND VENTS INSTALLED | JERRYF | JERRYF | | HI | C | 6014495 |
AIRTECH MECHANICAL, INC. | HD | P | 11/02/2018 | LIGHT TEST OK - OK FOR 2 LAYERS - MUA AND SA DUCT AT HARD LID AREA OK FOR WRAP - NEED PLAN REVISION FOR CHANGING FROM FACTORY DUCT TO WELDED | JERRYF | JERRYF | | HD | P | 6014488 |
AIRTECH MECHANICAL, INC. | HD | P | 10/31/2018 | HOOD WALL OK VERIFIED BY PICTURES - SEE IMAGES | JERRYF | JERRYF | | HD | P | 6011285 |
AIRTECH MECHANICAL, INC. | HD | P | 10/30/2018 | GREASE DUCT LIGHT TEST AT SHOP - 2 CURB DROPS AND 2 HOOD TRANSITIONS PASS LIGHT TEST. OK TO WRAP CURB DROPS. SHOULD ONLY HAVE A TOTAL OF 4 BUTT JOINTS TO BE LIGHT TESTED ON SITE. HOOD WALL - LOOKS LIKE THE HOOD WALL HAS ZERO COMBUSTIBLES PER PICTURES PROVIDED BY CONTRACTOR. | MARKB | MARKB | | HD | P | 6010701 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 01/15/2019 | plan splice for pb done, correction made | JOSEPHD | JOSEPHD | | P= | C | 6078915 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 01/02/2019 | Men's lavatory over 34" (at 34-3/8"), need plan splice from PB inspection, rest ok. | DANR | DANR | | P= | P | 6066522 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | C | 11/01/2018 | Still need base revisions by final , check water heater at final, AAV hand sink at bar area | SHANEN | SHANEN | | PTO | C | 6013473 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 10/26/2018 | DWV and domestic water in hood wall and domestic water overhead to bar area - test OK | SHANEN | SHANEN | | PTO | P | 6007692 |
LANDMARK PLUMBING AND HEATING, INC. | PB | P | 10/08/2018 | Plans reflect 3" drains to floor drains / floor sinks and cast iron p-traps, need engineers letter for installed 2" drains and PVC p-traps in kitchen and bar area, restrooms OK, test OK, cover at own risk | SHANEN | SHANEN | | PB | P | 5988826 |
LANDMARK PLUMBING AND HEATING, INC. | XMS | P | 01/14/2019 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical: delta 2 | DALEH | DALEH | | XMS | P | 6077579 |
LANDMARK PLUMBING AND HEATING, INC. | XPS | T | 01/14/2019 | PAID (REC#1569325) PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Plumbing splice 1/14/19 Delta 2 &3 revisions, reference inspector notes. | SHANEN | SHANEN | | XPS | T | 6077502 |