AQUAWORKS CONSTRUCTION INC. | B= | C | 12/11/2019 | items corrected / no fire final required per plan sticker that has it marked N/A / final OK pending other finals | DANE | DANE | | B= | C | 6424792 |
AQUAWORKS CONSTRUCTION INC. | B= | P | 12/10/2019 | gates still not self closing and latching / still need code compliant exit signs / still need fire final as fire plan review has been done and nothing is noted that no fire final is required / all other items corrected -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): ADVANTAGE HEATING & COOLING Mechanical Final Inspection is not Completed yet. | DANE | DANE | | B= | P | 6422796 |
AQUAWORKS CONSTRUCTION INC. | B= | R | 12/06/2019 | still need both gates to be self closing and latching and to only swing i the direction of egress / still need occupancy load sign stating occupancy of 183 / still need exit signs at both gates / still have gap greater than 4" under north gate / need fire final per sticker on approved plans and nothing showing in computer / letter for pool reinforcement on file. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), ADVANTAGE HEATING & COOLING Mechanical Final Inspection is not Completed yet. | DANE | DANE | | B= | R | 6418800 |
AQUAWORKS CONSTRUCTION INC. | BFT | C | 12/06/2019 | engineer observation for pool reinforcement on file | DANE | DANE | | BFT | C | 6418475 |
AQUAWORKS CONSTRUCTION INC. | B= | R | 12/05/2019 | still need engineer observation for pool reinforcement to complete BFN / still have gap greater than 4" under north gate / now neither gate is self closing and latching / emergency contact number and ring and hook all now OK. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | R | 6417505 |
AQUAWORKS CONSTRUCTION INC. | B= | R | 12/04/2019 | still need engineer observations for pool reinforcement to complete BFN / need to remove the locking thumb latches at the tops of both gates to make them single action / gaps greater than 4" under gates and fences / need to install emergency flotation ring and hook / missing sign with emergency contact number. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), SOUTH CENTRAL ELECTRIC LLC Electrical Final Inspection is not Completed yet. | DANE | DANE | | B= | R | 6415711 |
AQUAWORKS CONSTRUCTION INC. | BSP | R | 11/21/2019 | pool light are to be inspected by electrical inspector / talked to contractor on phone and discussed need to have electrical contractor call inspection and discussed need for all engineer observations for pool reinforcement | DANE | DANE | | BSP | R | 6406856 |
AQUAWORKS CONSTRUCTION INC. | BSP | P | 10/07/2019 | Met contractors from Garrett Construction on site to discuss pool inspections. Discussed need for permit for equipment enclosure as the only drawing for he enclosure are on the landscaping pages of building 1 permit and those drawing are only stamped by an engineer that is not a Colorado licensed structural engineer. Discussed either splicing onto building 1 permit or getting a separate permit for the enclosure. Discussed all items needed for pool final including accessible elements and exiting and fencing and safety equipment and signs / still need all engineer observations for pool submitted to pool permit | DANE | DANE | | BSP | P | 6359632 |
AQUAWORKS CONSTRUCTION INC. | BE | L | 06/04/2019 | Renewed at 6/4/2019 3:22:04 PM | TERRI | TERRI | | BE | L | 6219964 |
SOUTH CENTRAL ELECTRIC LLC | E= | C | 12/05/2019 | | JOHNN | JOHNN | | E= | C | 6417166 |
SOUTH CENTRAL ELECTRIC LLC | E= | P | 12/04/2019 | I need to talk to Dean about this. | JOHNN | JOHNN | | E= | P | 6416050 |
SOUTH CENTRAL ELECTRIC LLC | E= | R | 12/03/2019 | field cancelled | BRET | BRET | | E= | R | 6413890 |
SOUTH CENTRAL ELECTRIC LLC | E= | R | 12/02/2019 | bond fence, pvc emerging from grade up to 6 feet must be schedule 80, breaker locks for pool pumps. install approved deck box for pool lights cables. panel labels | BRET | BRET | | E= | R | 6412723 |
SOUTH CENTRAL ELECTRIC LLC | E= | P | 11/22/2019 | low voltage lights, plastic housing, potting not required, pool lights only okay to set | GARYL | GARYL | | E= | P | 6408286 |
SOUTH CENTRAL ELECTRIC LLC | ESL | P | 10/02/2019 | bonding okay to pool equipment room from outside, equipment room is all that is left for pool inspection and pole lights as well | GARYL | GARYL | | ESL | P | 6355109 |
SOUTH CENTRAL ELECTRIC LLC | ESL | P | 09/04/2019 | #6 ran around pool within 2', mesh bonded, sockets bonded, 4-corners okay, | GARYL | GARYL | | ESL | P | 6323694 |
SOUTH CENTRAL ELECTRIC LLC | EUG | P | 04/01/2019 | pool coping bonding 4 corners --------OK | CRAIGS | CRAIGS | | EUG | P | 6150621 |
SOUTH CENTRAL ELECTRIC LLC | EUG | P | 01/23/2019 | Pool bonding /// inside only , 5-corners | GARYL | GARYL | | EUG | P | 6085842 |
ADVANTAGE HEATING AND COOLING | HWP | C | 12/11/2019 | | LIDO | LIDO | | HWP | C | 6423546 |
ADVANTAGE HEATING AND COOLING | H= | C | 12/11/2019 | GAS INSPECTED ON PERMIT # M62625. (MECHANICAL HEAT FINAL OK.) | LIDO | LIDO | | H= | C | 6423545 |
ADVANTAGE HEATING AND COOLING | HSP | P | 12/10/2019 | CONTRACTOR MUST CONTACT REGIONAL BUILDING DEPARTMENT TO BE REMOVED FROM THIS PERMIT AND ATTACHED TO PERMIT # M62625 AND MECHANICAL NOTES TRANSFERRED. CONTRACTOR TO REQUEST INSPECTION AFTER THIS HAS BEEN COMPLETED. | LIDO | LIDO | | HSP | P | 6421962 |
ADVANTAGE HEATING AND COOLING | H= | P | 12/09/2019 | PARTIAL PENDING- NEED TO RESEARCH POOL AND SPA HEATER SHOWN ON THIS PERMIT AND PERMIT # M62625. SPA AND POOL BOILER INSTALL OK. (1- 250K / 1-500K. ) | LIDO | LIDO | | H= | P | 6421115 |
SOUTH CENTRAL ELECTRIC LLC | XES | P | 11/14/2019 | PLAN SPLICE: (No Fee) by: SHELBY for Electrical: Remove pool equipment from scope | SHELBY | SHELBY | | XES | P | 6400055 |
AQUAWORKS CONSTRUCTION INC. | XPS | P | 11/11/2019 | PLAN SPLICE: (No Fee) by: SHANEN for Plumbing: 11/11/19: Splice to remove entire Plumbing scope from this Pool permit | SHANEN | SHANEN | | XPS | P | 6394318 |
AQUAWORKS CONSTRUCTION INC. | XMS | T | 11/11/2019 | PAID (REC#1645801) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: See inspector alerts for comments | DALEH | DALEH | | XMS | T | 6394299 |