HOMEOWNER | BFR | C | 05/30/2019 | Frame corrections complete / Reviewed Smoke and CO requirements / | JUSTINL | JUSTINL | | BFR | C | 6214558 |
HOMEOWNER | BFR | P | 05/22/2019 | 1. Need mechanical permit and inspections / 2. Missing floating wall spikes every 36" at multiple locations throughout / 3. Complete fireblock at top of furred out walls and drop down ceilings / 4. Complete fireblock at top plate penetrations / 5. Remove floating wall blocks / Contact inspector in regards to smoke and CO requirements - Will be checked at final / Will need guard at open side of stairs - Will check at final | JUSTINL | JUSTINL | | BFR | P | 6207332 |
MEYER ELECTRIC | E= | C | 07/24/2019 | | TOMC | TOMC | | E= | C | 6275764 |
MEYER ELECTRIC | ER | C | 05/22/2019 | ER OK ------ | GREGM | GREGM | | ER | C | 6207559 |
ALTITUDE HEATING AND AIR, INC. | H= | C | 09/11/2020 | REVIEWED PICTURES AND CLOSED PERMIT. | JON | JON | | H= | C | 6703693 |
ALTITUDE HEATING AND AIR, INC. | H= | L | 02/04/2020 | CANCELED BECAUSE OF WEATHER/ | CHADP | CHADP | | H= | L | 6472935 |
ALTITUDE HEATING AND AIR, INC. | H= | P | 01/13/2020 | INSTALL TRANSFER AIR IN BEDROOMS( HOMEOWNER STATED THAT HE WANTED TO UNDERCUT THE BEDROOM DOORS) FINISHED BASEMENT / DIRECT VENT FURNACE / A/C COMPLETE / LOUVER DOOR/ No outside air to furnace return / | CHADP | CHADP | | H= | P | 6450937 |
ALTITUDE HEATING AND AIR, INC. | HRR | C | 05/29/2019 | | KYLEW | KYLEW | | HRR | C | 6213502 |
ALTITUDE HEATING AND AIR, INC. | HRR | P | 05/23/2019 | BUILDING CAVITY CAN NOT BE USED AS A RETURN FOR BASEMENT HALLWAY RETURN. HOW MANY CFM IS THE FAN IN THE CIGAR ROOM? TOTAL OF 65' OF 6" IS RAN FOR THAT FAN. NOTES: FINISHED BASEMENT, NO OSA, DIRECT VENT FURNACE, A/C COMPLETE. | KYLEW | KYLEW | | HRR | P | 6208732 |
ADVANTAGE SEWER & DRAIN, LLC | P= | C | 01/13/2020 | Corrections made, images uploaded | MALYNDA | MALYNDA | | P= | C | 6450307 |
ADVANTAGE SEWER & DRAIN, LLC | P= | P | 11/07/2019 | Bar sink is s-trapped and missing the aav, unable to locate aav for steam room, rest ok.
| MALYNDA | MALYNDA | | P= | P | 6391841 |
ADVANTAGE SEWER & DRAIN, LLC | PB | C | 05/29/2019 | underground ok. | TAYLOR | TAYLOR | | PB | C | 6212570 |
ADVANTAGE SEWER & DRAIN, LLC | PTO | C | 05/29/2019 | see images. | TAYLOR | TAYLOR | | PTO | C | 6212569 |
ADVANTAGE SEWER & DRAIN, LLC | PTO | P | 05/28/2019 | need of pictures of nail protection and vent connection, rest ok, note: aav in wall for shower next to mech room. | TAYLOR | TAYLOR | | PTO | P | 6211181 |
ADVANTAGE SEWER & DRAIN, LLC | PTO | P | 05/22/2019 | waive trip fee, still lost test and can not horizontal dry vent shower next to mech room, rest ok, need proper clearances and union at steam generator by final. | TAYLOR | TAYLOR | | PTO | P | 6207574 |
ADVANTAGE SEWER & DRAIN, LLC | PTO | P | 05/09/2019 | add steam generator and bar sink to scope of work, lost test and can not horizontal dry vent shower next to mech room, install steam line and need installation instructions for generator, still need to attach to building permit as previously noted, rest ok, VTR for bathroom, aav at bar sink. | TAYLOR | TAYLOR | | PTO | P | 6199864 |
ADVANTAGE SEWER & DRAIN, LLC | PTO | P | 04/18/2019 | need to verify underground piping for shower and bar sink, re- grade vent for double lavs, correct scope of work, attach to building permit M08182, cap old vent and drains next to mech room, install piping for steam generator, re- inspect all. | TAYLOR | TAYLOR | | PTO | P | 6199863 |