BUILTRITE BUILDERS | B= | C | 07/20/2020 | | JANE | JANE | | B= | C | 6642973 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BE | T | 07/06/2020 | PAID (REC#1693497): TCO | JANE | JANE | | BE | T | 6627622 |
WESTERN FIREPLACE SUPPLY, INC. | BE | C | 06/30/2020 | TCO fee | JANE | JANE | | BE | C | 6623051 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | B= | P | 06/30/2020 | Temp CO: need zoning ( Expires: 7/30/2020 12:00:00 AM) | JANE | JANE | | B= | P | 6623050 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | B= | P | 06/30/2020 | Items corrected. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | CHRISTINEH | CHRISTINEH | | B= | P | 6622928 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | B= | R | 06/24/2020 | Missing Gaurdrail and continuous graspable handrail at rear deck stairs / Complete outside agency final inspections / Rear decks - Finished basement - AC installed. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | TIMOTHYS | TIMOTHYS | | B= | R | 6616702 |
BUILTRITE BUILDERS | BFR | C | 06/24/2020 | | TIMOTHYS | TIMOTHYS | | BFR | C | 6616701 |
BUILTRITE BUILDERS | BFD | C | 06/24/2020 | Drain daylights West | TIMOTHYS | TIMOTHYS | | BFD | C | 6616699 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BLA | C | 04/23/2020 | | CHRISTINEH | CHRISTINEH | | BLA | C | 6550254 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BLA | P | 04/22/2020 | Seal exterior lights on rear elevation behind 2 car garage / Rest ok | CHRISTINEH | CHRISTINEH | | BLA | P | 6548749 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BIN | C | 03/31/2020 | Insulation certificate and sprinkler inspection on file | CHRISTINEH | CHRISTINEH | | BIN | C | 6526265 |
BUILTRITE BUILDERS | BFR | P | 03/31/2020 | ATP6 Hangers at porch (Can check at final) / Rest ok | CHRISTINEH | CHRISTINEH | | BFR | P | 6526263 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BIN | P | 03/26/2020 | Need certificates for blown-in and spray foam insulation / Pending completion of BFR / Complete all required external inspections (to include fire sprinkler system) | CHRISTINEH | CHRISTINEH | | BIN | P | 6523161 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BFR | P | 03/13/2020 | Received engineer letters for trusses / Complete draftstop and air barriers at basement throughout / APT6 hardware not fully installed at rear porch cover at posts / Rest ok / Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / | CHRISTINEH | CHRISTINEH | | BFR | P | 6510972 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BFR | P | 03/13/2020 | Updated truss packet on file / On site framing reinspect added for today | CHRISTINEH | CHRISTINEH | | BFR | P | 6509772 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BSP | P | 03/10/2020 | training with Christine K - reviewed elements of custom frame including trusses , shear transfer, interior shear walls retaining walls as part of permit / | BOBF | BOBF | | BSP | P | 6506401 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BFR | T | 03/10/2020 | PAID (REC#1668125) Training with Bob F / Too many items to list / Need to verify hold downs, shear walls, truss calc changes, etc. | CHRISTINEH | CHRISTINEH | | BFR | T | 6506355 |
BUILTRITE BUILDERS | BFN | C | 09/25/2019 | Items completed - see BFT | CHRISTINEH | CHRISTINEH | | BFN | C | 6346716 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BFT | C | 09/25/2019 | Open hole on file - bearing capacity verified 2400 psf / Recommended backfilled soil verified via letter | CHRISTINEH | CHRISTINEH | | BFT | C | 6346714 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BFN | P | 09/23/2019 | See BFT notes | CHRISTINEH | CHRISTINEH | | BFN | P | 6343671 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BFT | P | 09/23/2019 | UPDATE: Upon further review - no open hole on file / soils report on file / 2400 PSF -- usable -- 5% / footing and foundation observation on file - ufer noted / foundation design on file (bearing pressure verified) | CHRISTINEH | CHRISTINEH | | BFT | P | 6343663 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BFD | P | 09/20/2019 | Usable drain and damproofing ok / No sump or tie-in observed | CHRISTINEH | CHRISTINEH | | BFD | P | 6343650 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | BE | C | 08/16/2019 | | NELIDA | NELIDA | | BE | C | 6304502 |
BUILTRITE BUILDERS | BFI | P | 01/31/2019 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFI | P | 6093739 |
BUILTRITE BUILDERS | BFD | P | 01/31/2019 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFD | P | 6093738 |
BUILTRITE BUILDERS | BFT | P | 01/31/2019 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 6093737 |
BUILTRITE BUILDERS | BFN | P | 01/31/2019 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 6093736 |
LINHARDT ELECTRIC, LLC | E= | C | 06/17/2020 | 50 amp a/c - Ok / Future Car Charger Pre wire in garage | BRETC | BRETC | | E= | C | 6607494 |
LINHARDT ELECTRIC, LLC | ES | C | 04/13/2020 | Residential Underground: 200 amp 3/w new res | CRAIGS | CRAIGS | | ES | C | 6538376 |
LINHARDT ELECTRIC, LLC | ES | R | 04/09/2020 | CSU has the road closed ---- please upload pictures of corrections | CRAIGS | CRAIGS | | ES | R | 6536171 |
LINHARDT ELECTRIC, LLC | ES | R | 04/07/2020 | 4/0 alum service entrance conductors requires #4 cu gec --- need # 4 cu to the bond bushing --- need bond screw ---- ufer has been covered up | CRAIGS | CRAIGS | | ES | R | 6533456 |
LINHARDT ELECTRIC, LLC | ER | C | 02/14/2020 | 2--#8 al -- oven finished basement --- no vac | CRAIGS | CRAIGS | | ER | C | 6482620 |
THE FURNACE GUY HEATING & COOLING | H= | C | 06/18/2020 | All corrections made. | MARK | MARK | | H= | C | 6610033 |
THE FURNACE GUY HEATING & COOLING | H= | P | 06/17/2020 | Need to install the screen for the water heater vent termination. See MFG Addendum 1503 which pertains to water heaters rated at 76K BTU and higher. Need a condensate drain tube as well. Vent on A/C condensate drain pipe is on the wrong side of the trap. Other corrections made: Regulator in basement ceiling has a plastic access panel, make up air added to laundry, gas piping labeled, fireplaces back up to each other. | MARK | MARK | | H= | P | 6607448 |
THE FURNACE GUY HEATING & COOLING | H= | P | 06/15/2020 | Need to label medium pressure. Need to label for inspection the gas regulator access in soffit. Where is the second fireplace?Need to install termination for water heater vent and install screen per mfg. Need a steel platform at window well or rotate service side of a/c condenser for access. Missing make up air to laundry room. Note: 6" damperd outside air to the furnace return. 1- a/c, Hi/Lo grills to mechanical room. Fireplace mantle clearance ok for main level (Living room) | MARK | MARK | | H= | P | 6604252 |
THE FURNACE GUY HEATING & COOLING | HRP | C | 02/10/2020 | 350# test okay. | MARK | MARK | | HRP | C | 6477672 |
O.M.A.G.M., INC. | HC | C | 02/10/2020 | RELEASE METER for medium pressure system. | MARK | MARK | | HC | C | 6477669 |
O.M.A.G.M., INC. | HI | C | 02/10/2020 | 10 lb test ok. Will need a 2# approval letter from gas company prior to final. Note: Medium pressure system with regulator (By final) in soffit, will need to be limited vent and access. Regulator in mechanical room also vent limited. Inspector to verify regulators are installed in correct position per regulator mfg. 3/4" CSST main. 2 furnaces / 1 water heater / 1 BBQ / 1- future patio heater (Over head) 2 fireplaces / | MARK | MARK | | HI | C | 6477662 |
THE FURNACE GUY HEATING & COOLING | HRP | R | 02/07/2020 | Lost test. | MARK | MARK | | HRP | R | 6476549 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 02/07/2020 | Return in master bedroom@ fireplace has been sealed. | MARK | MARK | | HRR | C | 6476545 |
THE FURNACE GUY HEATING & COOLING | HRP | R | 01/29/2020 | NO TEST ON REFRIGERATION LINE | BILLS | BILLS | | HRP | R | 6468401 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 01/29/2020 | MISSING ALL EXHAUST FANS. SEAL MASTER SUITE RETURN AIR PIPE AT FLOOR LINE IN FIREPLACE ENCLOSURE (LARGE HOLE IN DUCT SEALANT). NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE X2 / IN-DIRECT VENT WATER HEATER / A/C ROUGH COIL AND LINESET (MAIN LEVEL SYSTEM) / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN X2 / | BILLS | BILLS | | HRR | P | 6468398 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 01/29/2020 | LETTER FROM MANUFACTURER ATTACHED, SEE IMAGES | BENH | BENH | | HV | C | 6467309 |
WESTERN FIREPLACE SUPPLY, INC. | HV | P | 01/22/2020 | Need letter from the mfg for method used as it's not per the installation instructions. | MARK | MARK | | HV | P | 6460324 |
WESTERN FIREPLACE SUPPLY, INC. | HV | P | 01/22/2020 | Vent pictures attached, will inspect the gaskets today. | MARK | MARK | | HV | P | 6459740 |
WESTERN FIREPLACE SUPPLY, INC. | HV | P | 01/16/2020 | Gasket is damaged on both sides of the SL7 fireplace. Unable to see vents above roof deck, pictures can be attached to permit or contractor to provide access.Frame clearances are ok on both main level fireplaces. | MARK | MARK | | HV | P | 6455485 |
WOLVERINE CONSTRUCTION LLC | P= | C | 06/16/2020 | finished bsmnt, tempering built into tub filler, pvb's ok | JOHNS | JOHNS | | P= | C | 6606703 |
WOLVERINE CONSTRUCTION LLC | PTO | C | 03/05/2020 | irrigation stub (x2), verify access panel for 3 part @ bsmnt (front wall) left of mech | JOHNS | JOHNS | | PTO | C | 6501193 |
WOLVERINE CONSTRUCTION LLC | PTO | P | 02/12/2020 | Need water stub, rest ok. | DANR | DANR | | PTO | P | 6480007 |
WOLVERINE CONSTRUCTION LLC | PTO | P | 02/05/2020 | Need further review on irrigation and toilet lines - will update notes in the morning, need insulation 3/4" and larger hot lines, need insulation recirc. line, need water stub, rest ok. AAV all basement lavs and bar, finished basement 2 bath - 1 bar, irrigation stub. Note: check water service connection at meter loop and sprinkler backflow at final, running trap for garage sink installed, master tub tempering in valve. | DANR | DANR | | PTO | P | 6474524 |
WOLVERINE CONSTRUCTION LLC | PB | C | 10/07/2019 | Ok. Note: check water stub through foundation at PTO. | DANR | DANR | | PB | C | 6359364 |
CUTTING EDGE CONSTRUCTION COMPANY LLC | XBS | T | 02/19/2020 | PAID (REC#1663201): PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Revised structural | SHELLEY | SHELLEY | | XBS | T | 6486482 |