DDR-33 | B= | C | 10/15/2019 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 6369147 |
DDR-33 | B= | P | 07/08/2019 | All items completed. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | P | 6256121 |
DDR-33 | B= | R | 07/02/2019 | need garage to house drywall separation at garage side to roof deck no more than 24" oc framing, missing insulation at rim and garage wall, complete siding and facia, caulk at exterior penetrations. unfinished basement. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NATHAN | NATHAN | | B= | R | 6251843 |
DDR-33 | BLA | C | 05/13/2019 | | NICK | NICK | | BLA | C | 6197041 |
DDR-33 | BIN | C | 04/01/2019 | Check attic at final | NICK | NICK | | BIN | C | 6150995 |
DDR-33 | BFR | C | 04/01/2019 | All frame items completed | NICK | NICK | | BFR | C | 6150986 |
DDR-33 | BFR | P | 03/28/2019 | Need to strap top plates of balloon frame walls / Need FHA straps for electrical at bearing east wall upper level / Need anchor bolts with in 12" of sill plate breaks throughout / OK to insulate | NICK | NICK | | BFR | P | 6147419 |
DDR-33 | BSP | P | 03/28/2019 | 3rd party observation on file for piers | NICK | NICK | | BSP | P | 6147411 |
DDR-33 | BFD | C | 03/28/2019 | 3rd party observation report on file | NICK | NICK | | BFD | C | 6147409 |
DDR-33 | BFN | C | 03/28/2019 | Soils on file / 3rd party observation report on file | NICK | NICK | | BFN | C | 6147408 |
DDR-33 | BFT | C | 03/28/2019 | Open hole and soils on file / 3rd party observation report on file / #2000psf / | NICK | NICK | | BFT | C | 6147404 |
DDR-33 | BSP | P | 03/12/2019 | Frame for support around wood stove vent in attic space OK / Still need all 3rd party observations for footing/foundation/drain / Still need open hole report | NICK | NICK | | BSP | P | 6131509 |
DDR-33 | BFI | P | 02/20/2019 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 6112135 |
DDR-33 | BFD | P | 02/20/2019 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 6112134 |
DDR-33 | BFT | P | 02/20/2019 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 6112133 |
DDR-33 | BFN | P | 02/20/2019 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 6112132 |
DEPAUL ELECTRIC | E= | C | 06/18/2019 | | JOHNN | JOHNN | | E= | C | 6235064 |
DEPAUL ELECTRIC | E= | R | 06/14/2019 | hallway 3 ways not right, need ladder for attic, ----------------------------20amp a/c | JOHNN | JOHNN | | E= | R | 6231508 |
DEPAUL ELECTRIC | ER | C | 03/26/2019 | correction made / | MIGUEL | MIGUEL | | ER | C | 6143977 |
DEPAUL ELECTRIC | ES | C | 03/22/2019 | Residential Underground: 200A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 6142546 |
DEPAUL ELECTRIC | ER | R | 03/22/2019 | ground exterior metal box in back / upload image w/ next inspection request / basement does not meet wall spacing, GC said basement unfinished / light in attic, provide ladder on final / | MIGUEL | MIGUEL | | ER | R | 6141890 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 06/14/2019 | note a/c complete, High/low grills / | DAVIDH | DAVIDH | | H= | C | 6231599 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 03/21/2019 | RELEASE METER | MATTM | MATTM | | HC | C | 6140019 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 03/21/2019 | | MATTM | MATTM | | HRR | C | 6140007 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HI | C | 03/20/2019 | 10LB TEST OK 1 1/4" MAIN 1 FURNACE 1 WATER HEATER 1 RANGE 1 DRYER 2 FUTURE GARAGE UNIT HEATERS | MATTM | MATTM | | HI | C | 6138881 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 03/20/2019 | COIL INSTALLED DOES NOT MATCH EQUIPMENT LISTED ON APPROVED DUCT DESIGN. CONTRACTOR MUST FILL OUT THE EQUIPMENT CHANGE FORM (RESIDENTIAL) AND ATTACH FORM TO AN INSPECTION REQUEST BY FINAL. FORM CAN BE FOUND ON THE PPRBD WEBSITE UNDER DOWNLOADS, RESIDENTIAL HANDOUTS, EQUIPMENT CHANGE RESIDENTIAL DUCT DESIGN. BY FINAL: PERFORMANCE TEST, NEED TO ADDRESS THE FOLLOWING: BATHROOM EXHAUST CANNOT BE WITHIN 3FT OF OUTSIDE AIR TO FURNACE RETURN, B-VENT LACKS CLEARANCE TO FRAMING IN UPPER LEVEL CHASE, NEED TO ISOLATE LIQUID LINE FROM DISSIMILAR METAL THROUGHOUT SOFFIT, NO UNIT HEATERS OR VENTS FOR UNIT HEATERS INSTALLED AT TIME OF INSPECTION NOTES: OUTSIDE AIR TO FURNACE RETURN, A/C ROUGH COIL AND LINESET | MATTM | MATTM | | HRR | P | 6138876 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 06/25/2019 | corrections made note: lav and toilet off garage will need a permit when finishing, rough was done at pto | JOSEPHD | JOSEPHD | | P= | C | 6243188 |
SPRINGS CUSTOM PLUMBING, INC. | P= | P | 06/20/2019 | need to complete bathroom off garage, need to anchor back silcock, rest ok note: no irrigation | JOSEPHD | JOSEPHD | | P= | P | 6238120 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 03/20/2019 | note: finished bathroom off garage, aav @ lav off garage, no irrigation | JOSEPHD | JOSEPHD | | PTO | C | 6138112 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 02/28/2019 | correction made | JOSEPHD | JOSEPHD | | PB | C | 6119980 |
SPRINGS CUSTOM PLUMBING, INC. | PB | P | 02/27/2019 | lost test on water main, rest ok | JOSEPHD | JOSEPHD | | PB | P | 6118975 |
DDR-33 | XBS | T | 03/04/2019 | PAID (REC#1580342) PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Revised floor framing. | BPHILLIPS | BPHILLIPS | | XBS | T | 6123803 |