HOMEOWNER | BIN | P | 12/13/2023 | Wall insulation ok Need attic by Final
Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / | PAULP | PAULP | | BIN | P | 7944123 |
HOMEOWNER | BFR | P | 11/14/2023 | complete HRR | PAULP | PAULP | | BFR | P | 7918378 |
HOMEOWNER | BFR | R | 11/02/2023 | Not ready Reviewed with homeowner | PAULP | PAULP | | BFR | R | 7907053 |
HOMEOWNER | BFR | R | 11/01/2023 | Stair hardware not secured and simpson tie hardware does not allow wood screws as fasteners Rest ok | PAULP | PAULP | | BFR | R | 7905886 |
HOMEOWNER | BFR | R | 09/25/2023 | Stair opening framing not to detail - missing double beams and all hardware at floor joists and landings
Need Foam and Fireblocking throughout Need Stamped observation for CMU infill per Page 10 stamped detail | PAULP | PAULP | | BFR | R | 7866713 |
HOMEOWNER | BE | L | 08/23/2023 | Renewed for $324.50 at 8/23/2023 3:53:39 PM (Receipt#1981451) | SYDNEYB | SYDNEYB | | BE | L | 7835660 |
HOMEOWNER | BSP | P | 05/12/2022 | Deck only. Deck final okay / UPDATE: 5/12/2022 by GregT-- Upon Further Review, Changed inspection from a Final (B=) to BSP / | GREGT | GREGT | | BSP | P | 7373812 |
HOMEOWNER | BSP | P | 05/12/2022 | Deck only -- Frame okay | GREGT | GREGT | | BSP | P | 7373811 |
HOMEOWNER | BE | L | 12/14/2021 | Renewed for $649.00 at 12/14/2021 2:27:41 PM (Receipt#1829584) | RITA | RITA | | BE | L | 7208790 |
HOMEOWNER | BFT | C | 08/11/2020 | Reinforcing for exterior piers OK | NICHOLEM | NICHOLEM | | BFT | C | 6668283 |
HOMEOWNER | BFT | P | 08/04/2020 | 2 interior pads OK / 6 exterior piers missing reinforcing per plan; depth and diameter OK | NICHOLEM | NICHOLEM | | BFT | P | 6660283 |
HOMEOWNER | BE | L | 05/28/2020 | Renewed for No Fee at 5/28/2020 10:26:43 AM | LONNYS | LONNYS | | BE | L | 6585548 |
HOMEOWNER | E= | R | 09/25/2023 | not ready / | MIGUEL | MIGUEL | | E= | R | 7866709 |
HOMEOWNER | ES | R | 09/25/2023 | inspection will be for EP / | MIGUEL | MIGUEL | | ES | R | 7866706 |
HOMEOWNER | ER | C | 09/18/2023 | lighting and hood on same circuit / countertop circuit on 18 in. countertop between sink and range / disposal/dishwasher and micro dedicated / 2 sm appliance ok / | MIGUEL | MIGUEL | | ER | C | 7859990 |
HOMEOWNER | ER | T | 09/07/2023 | PAID (REC#1988756) need to add circuits to kitchen and meet wall spacing at kitchen counter top, discussed with homeowner / rest ok / | MIGUEL | MIGUEL | | ER | T | 7850139 |
HOMEOWNER | ER | L | 08/25/2023 | still need outlet for jet tub within 12" of access / still need to add outlets for kitchen spacing, if hood is being installed power is required / correct outlets at added walls at arches / | MIGUEL | MIGUEL | | ER | L | 7838302 |
HOMEOWNER | ER | R | 02/17/2023 | need exterior outlets x3 / bonding for jet tub, outlet required to be within 12" of access / need kitchen layout to verify spacing / add outlet at bottom of stairs on east side / replace #14 cable w/ #12 for exterior lights x 2 / no #14 installed / | MIGUEL | MIGUEL | | ER | R | 7663915 |
HOMEOWNER | E16 | C | 11/29/2022 | Discussed AFCI/GFCI/TR requirements with owner. / discussed wall and kitchen counter top spacing, exterior outlets, jet tub outlet, 30" requirement for panel / dedicated circuits / | MIGUEL | MIGUEL | | E16 | C | 7594982 |
HOMEOWNER | HRR+ | C | 11/28/2023 | CORRECTIONS MADE / ABOVE SOFFIT RANGE EXHAUST OK | SEANM | SEANM | | HRR+ | C | 7929059 |
HOMEOWNER | HRR+ | P | 11/14/2023 | COMPLETE THE RETURNS IN BOTH BEDROOMS / COMPLETE RANGE HOOD DUCT ABOVE SOFFIT | MICHAELM | MICHAELM | | HRR+ | P | 7917932 |
HOMEOWNER | HRR+ | L | 08/25/2023 | Permit locked to keep it in administratively closed status / PAN BOTH BEDROOM RETURNS OUT OF WALLS THROUGH ALCOVE / INSTALL RANGE HOOD DUCT | MICHAELM | MICHAELM | | HRR+ | L | 7838322 |
HOMEOWNER | HC | C | 11/29/2022 | RELEASE METER. 2-LB SYSTEM | BILLS | BILLS | | HC | C | 7594582 |
HOMEOWNER | HRR | C | 11/29/2022 | EMAILED PICTURES OF CORRECTIONS MADE, WILL UPLOAD TO PERMIT IMAGES ON THE FOLLOWING BUSINESS DAY. BY FINAL: NEED EQUIPMENT CHANGE LETTERS FOR THE FURNACE AND COIL (PAYNE SPEC'D, GOODMAN INSTALLED). NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE / DIRECT VENT WATER HEATER / A/C ROUGH COIL AND LINESET / NO OUTSIDE AIR TO FURNACE RETURN / | BILLS | BILLS | | HRR | C | 7594571 |
HOMEOWNER | HRR | P | 11/29/2022 | Only 1 picture attached / You can send the others to michaelm@pprbd.org OR an on site inspection can be requested | MICHAELM | MICHAELM | | HRR | P | 7594349 |
HOMEOWNER | HRR | P | 11/23/2022 | NEED RETURN AIR INSTALLED IN BASEMENT. REMOVE ABANDONED DRYER EXHAUST TERMINATION HOOD ON UPPER LEVEL NORTH WALL BY THE SLIDING GLASS DOOR. REMOVE THE EXISTING EXHAUST FAN AT THE SOUTH BASEMENT WALL THAT IS BETWEEN THE EXTERIOR WALL AND THE NEW FRAMED WALL.CONTRACTOR TO ATTACH PICTURES AT NEXT INSPECTION REQUEST. Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / BY FINAL: NEED EQUIPMENT CHANGE LETTERS FOR THE FURNACE AND COIL (PAYNE SPEC'D, GOODMAN INSTALLED). NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE / DIRECT VENT WATER HEATER / A/C ROUGH COIL AND LINESET / NO OUTSIDE AIR TO FURNACE RETURN / | BILLS | BILLS | | HRR | P | 7591772 |
DAVIS GAS SHOP INC | HI | C | 11/22/2022 | 10 lb test ok / Note / 1 inch main at 90' / 1 furnace / 1 water heater / 1 range / (SYSTEM IS 2 lb.) / All medium pressure labels applied / | PAULO | PAULO | | HI | C | 7590965 |
HOMEOWNER | HI | R | 11/16/2022 | TRIP FEE WAIVED THIS TIME ONLY / NO ACCESS | SEANM | SEANM | | HI | R | 7585545 |
DAVIS GAS SHOP INC | HI | P | 11/15/2022 | NO ACCESS INTO HOME, CONTRACTOR OR HOMEOWNER TO BE ON SITE FOR NEXT INSPECTION / UNABLE TO VERIFY SIZING AND APPLIANCE CONNECTIONS / 10 LB TEST OK TODAY / | STEPHANIEV | STEPHANIEV | | HI | P | 7583932 |
HOMEOWNER | P= | L | 08/25/2023 | No ready for final. | DANR | DANR | | P= | L | 7838470 |
HOMEOWNER | PTO | C | 11/06/2020 | Added AAV for double lavs at basement in lieu of tub. | SAMH | SAMH | | PTO | C | 6768306 |
HOMEOWNER | PTO | P | 11/02/2020 | Need listing for basement tub. Leak at basement tub valve, Need approved fittings at waste and overflow at basement tub. | SAMH | SAMH | | PTO | P | 6762096 |
HOMEOWNER | PTO | R | 10/27/2020 | Need Nail Protection Through-out / Need To Support Valves Through-out / Check For Water To Be On Test And Completed / Rest OK Note: Need Access Below And Behind Each Tub For Slip Joint Access / Need Access To Pump For Tubs / Need Mixing Valve Or Tempering Valve @ Water Heater / | TRAVISR | TRAVISR | | PTO | R | 6755540 |
HOMEOWNER | PB | C | 09/01/2020 | Existing Water stub in. | SAMH | SAMH | | PB | C | 6692213 |