ART C KLEIN CONSTRUCTION, INC. | B= | C | 10/17/2019 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 6371466 |
ART C KLEIN CONSTRUCTION, INC. | B= | P | 08/23/2019 | pending completion of all other required final inspections, building okay. Additional Inspections Required (computer generated): BERWICK ELECTRIC CO Electrical Final Inspection is not Completed yet, HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet, MAUI MECHANICAL, INC. Mechanical Final Inspection is not Completed yet. | BOBF | BOBF | | B= | P | 6312605 |
ART C KLEIN CONSTRUCTION, INC. | B= | P | 06/03/2019 | pending completion of all other required inspections building okay. Additional Inspections Required (computer generated): BERWICK ELECTRIC CO Electrical Final Inspection is not Completed yet, HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet, MAUI MECHANICAL, INC. Mechanical Final Inspection is not Completed yet. | BOBF | BOBF | | B= | P | 6218099 |
ART C KLEIN CONSTRUCTION, INC. | BFR | P | 05/31/2019 | drywall install on lid of rated ceiling okay | BOBF | BOBF | | BFR | P | 6216108 |
ART C KLEIN CONSTRUCTION, INC. | BFR | P | 05/29/2019 | framing and drywall install on top of rated ceiling assembly in hallway per WP 1072 okay | BOBF | BOBF | | BFR | P | 6213121 |
ART C KLEIN CONSTRUCTION, INC. | BFR | R | 05/03/2019 | approved plans show rated walls in hallway going to roof deck, with no rated lid, need to revise plans showing rated walls with rated horizontal ceiling, also need rated horizontal assembly, proposed ceiling was a WP 1072 (wall assembly) | BOBF | BOBF | | BFR | R | 6186227 |
ART C KLEIN CONSTRUCTION, INC. | BFR | P | 04/26/2019 | Need MEP attached to Permit / framing repairs for all wall OK pending other Roughs / need to inspect hard lid framing in Hall areas | RICHB | RICHB | | BFR | P | 6179134 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 08/27/2019 | | CRAIG | CRAIG | | E= | C | 6315742 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 06/17/2019 | Still need kitchen hood and ANSUL system hooked up----need splice on prints showing dishwasher hood and kitchen hood-------all else okay. | CHIPO | CHIPO | | E= | P | 6233605 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 06/10/2019 | sales counter for Novo coffee and above ceiling ok | CRAIG | CRAIG | | E= | P | 6226146 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 06/10/2019 | above ceiling in kitchen area ok Not ready is in washer area , conduit in way to disconnect ------ ko plug disconnects --------- Ansul system for equipment not connected ----------- AHU' S needs to all be inspected no notes from electrical or mechanical ?? | CRAIG | CRAIG | | ER | P | 6226139 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 06/03/2019 | cooler / freezer | CRAIG | CRAIG | | ER | P | 6217999 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 06/03/2019 | bristol tap and novo coffee seating area only | CRAIG | CRAIG | | E= | P | 6217989 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/29/2019 | above ceiling in Novo coffee sale area | CRAIG | CRAIG | | ER | P | 6213724 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/24/2019 | above ceiling in bristol tap in dining area 255 ok | CRAIG | CRAIG | | ER | P | 6210100 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/08/2019 | Novo caffee shop walls ok marked on plans | CRAIG | CRAIG | | ER | P | 6192197 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/08/2019 | Novo caffee shop walls ok marked on plans | CRAIG | CRAIG | | ER | P | 6192191 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/07/2019 | walls hi-lighted in orange on page E1.1 | TOMC | TOMC | | ER | P | 6190700 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | R | 05/01/2019 | called in wrong --------- needs to be L90988 permit | CRAIG | CRAIG | | ER | R | 6183890 |
HVAC SOLUTIONS, INC. | H= | C | 10/17/2019 | LETTER FOR 3RD PARTY DAMPER TESTING RECEIVED AND STAMPED - SEE IMAGES | MARKB | MARKB | | H= | C | 6371465 |
MAUI MECHANICAL, INC. | H= | C | 09/05/2019 | PER CONTRACTOR - REFRIGERATION QUANTITY IS BELOW AMOUNT REQUIRED FOR ALARMS | MARKB | MARKB | | H= | C | 6324533 |
MAUI MECHANICAL, INC. | H= | P | 09/04/2019 | Need contractor to provide refrigerate amounts, OTHER ITEMS ADDRESSED | MARKB | MARKB | | H= | P | 6322763 |
HVAC SOLUTIONS, INC. | HSP | C | 08/15/2019 | Fire dampers have to be inspected for operation per engineer and this would be through 3rd party to engineer or Fire Department. | JACK | JACK | | HSP | C | 6301573 |
HVAC SOLUTIONS, INC. | HSP | P | 08/13/2019 | Engineering Letter received - ADDRESSING - refrigeration, hood, duct & F/S dampers. WILL NEED CONTRACTOR TO VERIFY CONDITION AND OPERATION OF DAMPERS IF NOT REPLACING PER ENGINEER LETTER. (Left message for Tim Donegan the morning of 8/14/19) Inspector cell phone number: 719-492-6353 | MARKB | MARKB | | HSP | P | 6297883 |
HVAC SOLUTIONS, INC. | HSP | P | 08/02/2019 | TEST AND BALANCE REPORT RECEIVED. Still need engineer to address fire smoke dampers that plans required to be replaced. Spoke with Tim D. (HVAC Solutions) | MARKB | MARKB | | HSP | P | 6286099 |
MAUI MECHANICAL, INC. | H= | P | 07/22/2019 | CONDENSATE LINES - Condensate lines in freezer do not have heat tape and seams insulation need to be sealed closed. Need to seal openings around pipes between cooler and freezer. Other items need to be addressed. | MARKB | MARKB | | H= | P | 6272199 |
HVAC SOLUTIONS, INC. | HSP | P | 05/31/2019 | NEW MECHANICAL SPLICE STILL SHOWS EXISTING FIRE/SMOKE DAMPERS BEING REMOVED AND REPLACED - SEE NOTE 1 SHEET M1.1 | MARKB | MARKB | | HSP | P | 6216353 |
MAUI MECHANICAL, INC. | HRP | C | 05/31/2019 | AT FINAL - Need plenum rated electrical conduit to condensers on top of cooler/freezer. Make sure cover goes on freezer condenser (currently has sprinkler line in way). Complete condensate lines. Note: If freezer goes over 7.23 Lbs of refrigerate, alarms will be required. PRESSURE TEST FOR WALK IN COOLER AND FREEZER COMPLETE. | MARKB | MARKB | | HRP | C | 6216238 |
HVAC SOLUTIONS, INC. | HD | P | 05/21/2019 | ----NEED PLUMBING AND REFRIGERATION CONTRACTORS ATTACHED TO PERMIT AND MECHANICAL SPLICE ADDRESSING AIR BALANCE OF HOOD---- ABOVE CEILING DUCT - SUPPLY BRANCHES INSTALLED IN KITCHEN PER PLAN EXCEPT FOR 16" IN DISH AREA OK TO WRAP. No flex or diffusers. | MARKB | MARKB | | HD | P | 6206045 |
HVAC SOLUTIONS, INC. | HSP | P | 05/06/2019 | ON SITE CONSULT WITH MECHANICAL CONTRACTOR AND BUILDING SUPER: Need refrigeration, plumbing and gas contractors attached to permit. Will need a plan splice where engineer addresses - Will need an AM&M filled out and submitted to plan review for refrigerate R448A called for on plans that is not in 2015 IMC charts. Refrigeration calculations have allowable amount of refrigerate but do not have amount being used. Need engineer to address hood by cooler being removed from common grease duct system and common makeup air system in respect to what needs to be done with systems for new balance. Will need new cook line equipment listed on plans. Will need existing duct in kitchen area to match plans for existing conditions. Engineer to show weather or not current fire/smoke dampers are to be replaced or left as existing. Note: Current hood and grease duct are existing and will not be touched or modified under current permit scope. | MARKB | MARKB | | HSP | P | 6188388 |
HVAC SOLUTIONS, INC. | HD | P | 05/06/2019 | ABOVE CEILING DUCT - SUPPLY BRANCHES FROM EXISTING MAINS INSTALLED PER PLAN FOR DINING AREAS # 251 & 255 OK TO WRAP. NO flex or diffusers at this time. | MARKB | MARKB | | HD | P | 6188340 |
FRONTIER MECHANICAL SYSTEMS INC | P= | C | 06/03/2019 | Novo coffee-- disconnect and reconnect existing fixtures | TED | TED | | P= | C | 6217624 |
HVAC SOLUTIONS, INC. | XMS | T | 09/17/2019 | PAID (REC#1630441) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: new splice removed 2 - F/S dampers they did not exist also showing as built | TCRIPPEN | TCRIPPEN | | XMS | T | 6337676 |
ART C KLEIN CONSTRUCTION, INC. | XBS | T | 05/28/2019 | PAID (REC#1601837) PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Provided detail for rated corridor. | BPHILLIPS | BPHILLIPS | | XBS | T | 6212230 |
HVAC SOLUTIONS, INC. | XMS | P | 05/22/2019 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical: delta 2 | DALEH | DALEH | | XMS | P | 6206757 |