ALL ABOUT HOME DESIGN, LLC | B= | C | 04/27/2020 | Crawlspace - No deck | ASHLEYB | ASHLEYB | | B= | C | 6553043 |
ALL ABOUT HOME DESIGN, LLC | BFR | C | 10/11/2019 | corrections made | NATHAN | NATHAN | | BFR | C | 6366285 |
ALL ABOUT HOME DESIGN, LLC | BIN | C | 10/11/2019 | | NATHAN | NATHAN | | BIN | C | 6366278 |
ALL ABOUT HOME DESIGN, LLC | BFD | C | 10/10/2019 | All Eng on file | NICK | NICK | | BFD | C | 6364108 |
ALL ABOUT HOME DESIGN, LLC | BFN | C | 10/10/2019 | Eng letter of observation on file for foundation | NICK | NICK | | BFN | C | 6364103 |
ALL ABOUT HOME DESIGN, LLC | BFT | C | 10/10/2019 | Eng observation on file for micro piles / Open hole on file / Drain usable | NICK | NICK | | BFT | C | 6364097 |
ALL ABOUT HOME DESIGN, LLC | BFR | P | 10/08/2019 | balloon frame master bedroom wall and 12" oc, 2 2x6 and MTS 12 strap at master tub and shower, need 2nd 2x8 at loft header, mechanical connection at top plates upstairs bedrooms dormer walls, missing nails in HUS26 south 2nd floor bedroom truss, strap plate breaks at main level walls, secure mono posts at crawlspace, foundation engineering on file. | NATHAN | NATHAN | | BFR | P | 6362205 |
ALL ABOUT HOME DESIGN, LLC | BSP | P | 08/23/2019 | front porch and porch sheer okay. | NATHAN | NATHAN | | BSP | P | 6313123 |
ALL ABOUT HOME DESIGN, LLC | BFD | P | 05/21/2019 | Drain of usable space OK / Damp proof OK / Drain daylights to back of house / Need all 3rd party observation reports for footing/foundation / Need open hole report / Need foundation design | NICK | NICK | | BFD | P | 6206320 |
ALL ABOUT HOME DESIGN, LLC | BFT | P | 05/20/2019 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 6204368 |
ALL ABOUT HOME DESIGN, LLC | BFN | P | 05/20/2019 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 6204367 |
POSITIVE ELECTRIC, LLC | E= | C | 04/20/2020 | corrections made / | MIGUEL | MIGUEL | | E= | C | 6545413 |
POSITIVE ELECTRIC, LLC | EP | C | 04/17/2020 | 200A sub panel in garage ok / | MIGUEL | MIGUEL | | EP | C | 6543907 |
POSITIVE ELECTRIC, LLC | E= | R | 04/17/2020 | install breaker lock for hood / need pic of fan box in master bedroom / Pics ok, upload images with next inspection request. If you encounter problems uploading images, please contact IT at 799-2688 / A/C #1-40A, #2-30A / car charger pre-wire only / | MIGUEL | MIGUEL | | E= | R | 6543903 |
POSITIVE ELECTRIC, LLC | ER | C | 09/19/2019 | will need to verify fan box used in master bedroom for final / corrections made / sump in crawler / | MIGUEL | MIGUEL | | ER | C | 6341100 |
POSITIVE ELECTRIC, LLC | ES | C | 09/18/2019 | Residential Underground: 200A 3w new res ok to set meter and seal / | MIGUEL | MIGUEL | | ES | C | 6340101 |
POSITIVE ELECTRIC, LLC | ER | R | 09/18/2019 | install fan box in master bedroom / add receptacle outside of bunk room and under window in bunk room / IR ufer connection / 4/0AL to sub panel in garage / no MCCs / 8/3AL x4 / 1/0AL to car charger / | MIGUEL | MIGUEL | | ER | R | 6340100 |
CUSTOM CLIMATE CONTROL | H= | C | 04/24/2020 | | KYLEW | KYLEW | | H= | C | 6550915 |
CUSTOM CLIMATE CONTROL | H= | P | 04/22/2020 | DUCT LEAKAGE REPORT RECEIVED, SEE IMAGES / MISSING PLAN SPLICE FOR 12"X10" SUPPLY DUCT IN CRAWLSPACE / PROVIDE A MINIMUM 30"X30" LEVEL SERVICE SPACE FOR ATTIC FURNACE PER THE 2009 IFGC SECTION 306.3 / CRAWLSPACE SUPPLY DAMPERS NEED TO BE MECHANICALLY LOCKED IN THE OPEN POSITION / FURNACE SERVING MAIN LEVEL NEEDS PROPER FILTER INSTALLATION, SEAL FURNACE TO COIL AND RETURN PLENUM / MISSING FIREPLACE INSTALLATION INSTRUCTIONS / ATTIC FURNACE VENT LACKS 1 INCH CLEARANCE TO ROOFING MATERIAL / NOTE / CONDITIONED CRAWLSPACE / 2X OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT FURNACE / 2X A/C COMPLETE / | MATTM | MATTM | | H= | P | 6548180 |
CUSTOM CLIMATE CONTROL | HC | C | 09/24/2019 | RELEASE METER | MATTM | MATTM | | HC | C | 6345817 |
CUSTOM CLIMATE CONTROL | HRR | C | 09/24/2019 | BY FINAL: PROVIDE PLAN SPLICE FOR 12"X10" SUPPLY DUCT IN CRAWLSPACE, PROVIDE A MINIMUM 30"X30" LEVEL SERVICE SPACE FOR ATTIC FURNACE PER THE 2009 IFGC SECTION 306.3, DUCT LEAKAGE REPORT | MATTM | MATTM | | HRR | C | 6345811 |
CUSTOM CLIMATE CONTROL | HRR | P | 09/19/2019 | ****UPDATE 9/19/19 BY MLM---REMOVED TRIP FEE, CHANGED TO PARTIAL****CONTRACTOR TO PROVIDE TALLER LADDER TO ACCESS ATTIC MECHANICAL EQUIPMENT, MAIN LEVEL FURNACE VENT TERMINATION REQUIRES A 3FT CLEARANCE TO INSIDE CORNER PER MANUFACTURES INSTALLATION INSTRUCTIONS PAGE 65 FIGURE 32 ITEM F. ALL DRYER DUCT TO BE SUPPORTED EVERY 4FT MAXIMUM, MISSING 7" SUPPLY TO OFFICE AND 4" SUPPLY TO CONDITION THE CRAWLSPACE, CRAWLSPACE SUPPLY CONNECTING EAST AND WEST SUPPLY MAIN IS UNDERSIZED PER PRINT, PRINT CALLS FOR 13"X11"/12"X10" INSTALLED. INSTALL PER PRINT OR SUBMIT PLAN SPLICE, SEAL EAST 6" SUPPLY TO DINING ROOM, CONTRACTOR TO SEAL AND MECHANICALLY FASTEN ALL SUPPLY HEAT RUNS AT MAIN TRUNK IN CRAWLSPACE, TOO MANY TO LIST, BY FINAL: OUTSIDE AIR TO FURNACE RETURN TO TERMINATE 12" ABOVE GRADE. PROVIDE DUCT LEAKAGE REPORT. TRIP FEES APPLIED. NOTES: CONDITIONED CRAWLSPACE, 2X OUTSIDE AIR TO FURNACE RETURN, DIRECT VENT FURNACE, INDIRECT VENT WATER HEATER, 2X A/C ROUGH COIL AND LINESET | MATTM | MATTM | | HRR | P | 6340884 |
CUSTOM CLIMATE CONTROL | HRR | R | 09/18/2019 | CONTRACTOR TO PROVIDE ACCESS TO CRAWLSPACE AND TO FURNACE AT ATTIC. RE-INSPECT ALL | BILLS | BILLS | | HRR | R | 6339353 |
SPRINGS GAS, INC. | HI | C | 08/22/2019 | 10LB TEST OK 1 1/2" MAIN 2 FURNACE 1 WATER HEATER 1 RANGE 1 FIREPLACE 1 FUTURE STUB AT EXTERIOR | MATTM | MATTM | | HI | C | 6311030 |
FIREPLACE WAREHOUSE | HV | C | 08/19/2019 | FIREPLACE FRAME AND VENT OK NOTE: 1 FIREPLACE ON MAIN LEVEL | MATTM | MATTM | | HV | C | 6305990 |
TEAM PLUMBING, INC. | P= | C | 04/10/2020 | rpbfp installed for irrigation | JOEL | JOEL | | P= | C | 6537715 |
TEAM PLUMBING, INC. | PTO | C | 09/23/2019 |
| JOHNS | JOHNS | | PTO | C | 6344794 |
TEAM PLUMBING, INC. | PTO | P | 09/20/2019 | bellied 3" pipe @ crawl space in a few areas, back grade @ 3" @ crawl space @ "1st" crawl space bay, rest ok | JOHNS | JOHNS | | PTO | P | 6343429 |
TEAM PLUMBING, INC. | PTO | P | 09/19/2019 | nail pro @ garage hot / cold hose bib, support / isolate incoming water @ crawl space from metal I-beams, pull water lines away from crawl space wall for insulation blanket, leak @ 3" wye @ mstr bath @ area marked w/ black X @ crawl space, need drain down valve @ irrigation shut off valve, need air gap @ t&p to be above pan, rest ok. NOTE: hanging base, crawl space, vtr (2), aav @ mech closet, both kitchen sinks, and all upr level lavs, tempering built into tub filler, by final need air gap @ t&p, verify rp and irrigation drain down @ mech @ final | JOHNS | JOHNS | | PTO | P | 6341468 |