VANTAGE HOMES CORP. | B= | C | 11/04/2019 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 6387156 |
VANTAGE HOMES CORP. | B= | P | 08/08/2019 | Partial finished basement / No deck / Mechanical room < 80 sq/ft /. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819). | JUSTINL | JUSTINL | | B= | P | 6293734 |
VANTAGE HOMES CORP. | BIN | C | 08/08/2019 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / 3rd Party Insulation Certificate on file / | JUSTINL | JUSTINL | | BIN | C | 6292839 |
VANTAGE HOMES CORP. | BFR | C | 06/06/2019 | Frame corrections complete / Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / Provide Test report for materials used for fire protection of floor per IRC 302.13 EX #4 / | JUSTINL | JUSTINL | | BFR | C | 6223171 |
VANTAGE HOMES CORP. | BFR | P | 06/05/2019 | 1. Missing fireblock at top plate penetrations throughout and at tub drains / 2. Missing bottom plate nailing at interior shear walls to be spaced 16" OC - Nail perpendicular trusses to interior shear wall at same spacing / 3. Missing LUS28s and corner hardware at basement landing / Finished basement / Plans reviewed electronically / Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / Provide Test report for materials used for fire protection of floor per IRC 302.13 EX #4 / | JUSTINL | JUSTINL | | BFR | P | 6221050 |
VANTAGE HOMES CORP. | BLA | C | 06/05/2019 | Lath complete | JUSTINL | JUSTINL | | BLA | C | 6221046 |
VANTAGE HOMES CORP. | BIN | P | 06/04/2019 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 6220113 |
VANTAGE HOMES CORP. | BSP | P | 05/15/2019 | Exterior shear fastening OK / Narrow braced wall OK / Front porch lid OK | JUSTINL | JUSTINL | | BSP | P | 6200464 |
VANTAGE HOMES CORP. | BFD | C | 05/15/2019 | Engineer letter for perimeter drain on file -- Damp proofing noted / Tie in to underdrain complete -- Verification on file / Drain ok / Contractor to backfill per requirements of Soils Report / | JUSTINL | JUSTINL | | BFD | C | 6199392 |
VANTAGE HOMES CORP. | BFN | C | 05/15/2019 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | JUSTINL | JUSTINL | | BFN | C | 6199389 |
VANTAGE HOMES CORP. | BFT | C | 05/15/2019 | Engineer letter for footing on file -- Open hole on file - 3000 PSF ( verified ) / Drain usable / 10% | JUSTINL | JUSTINL | | BFT | C | 6199387 |
VANTAGE HOMES CORP. | BFD | P | 04/04/2019 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFD | P | 6154666 |
VANTAGE HOMES CORP. | BFT | P | 04/04/2019 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 6154665 |
VANTAGE HOMES CORP. | BFN | P | 04/04/2019 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 6154664 |
D & J QUALITY ELECTRIC INC | E= | C | 07/24/2019 | E= OK -----A/C PRE WIRE------ | GREGM | GREGM | | E= | C | 6275098 |
D & J QUALITY ELECTRIC INC | ES | C | 07/11/2019 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | GREGM | GREGM | | ES | C | 6260239 |
D & J QUALITY ELECTRIC INC | EUG | C | 07/11/2019 | EUG OK -----4/0------ | GREGM | GREGM | | EUG | C | 6260235 |
D & J QUALITY ELECTRIC INC | ER | C | 06/04/2019 | ER OK ----- | GREGM | GREGM | | ER | C | 6219496 |
D & J QUALITY ELECTRIC INC | ER | R | 05/31/2019 | NEED NOTCH PLATES ABOVE PANEL-------REST OK -----# 8 CU COOK TOP WALL OVEN----# 8 AL A/C -----NO MCC----- | GREGM | GREGM | | ER | R | 6216497 |
D & J QUALITY ELECTRIC INC | ER | R | 05/29/2019 | NOT READY------ | GREGM | GREGM | | ER | R | 6213147 |
GOSSAGE CONSTRUCTION | H= | C | 08/06/2019 | - Whole house ventilation provided by 150 CFM exhaust within bathroom #2. Switch is located within mechanical closet. - NOTES: Finished basement. Outside air to furnace return with damper located within basement bedroom #2 closet. Direct vent furnace. High low transfers to mechanical room. A/C Rough line-set only. | RANDYB | RANDYB | | H= | C | 6290625 |
GOSSAGE CONSTRUCTION | H= | P | 07/31/2019 | Supply drop has been covered in basement bedroom. Unable to locate labeled whole house ventilation switch. Damper to outside air duct required to be accessible. Notes-- Finished basement. Outside air to return with damper. High/low transfer air to mechanical room. AC rough line set. Direct vent furnace. | JEFFL | JEFFL | | H= | P | 6284190 |
GOSSAGE CONSTRUCTION | HC | C | 06/04/2019 | RELEASE METER | JEFFL | JEFFL | | HC | C | 6220079 |
GOSSAGE CONSTRUCTION | HRR | C | 06/04/2019 | **All mechanical with moving parts required to be accessible at final, including back draft damper** | JEFFL | JEFFL | | HRR | C | 6220071 |
PRECISION PLUMBING | HI | C | 05/24/2019 | 10LB TEST OK. 1" MAIN, 1 FURNACE, 1 WATER HEATER, 1 COOKTOP, 1 FIREPLACE | BILLS | BILLS | | HI | C | 6210102 |
GOSSAGE CONSTRUCTION | HRR | P | 05/24/2019 | NEED DRYER EXHAUST FRAMING COMPLETED AT TRUSS LINE, SEAL ELBOW GORES AT KITCHEN EXHAUST, TIGHTEN WATER HEATER SUPPORT HANGERS THROUGHOUT. BY FINAL: CONFIRM OUTSIDE AIR DAMPER ACCESS IN CLOSET BEHIND FURNACE. WHOLE HOUSE VENTILATION FROM A 150 CFM EXHAUST AT BATHROOM #2 WITH CONTROLS TO BE DETERMINED. NOTE: FINISHED BASEMENT, DIRECT VENT FURNACE, A/C ROUGH LINESET ONLY, DAMPERED OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | HRR | P | 6210088 |
FIREPLACE WAREHOUSE | HV | C | 05/17/2019 | FIREPLACE VENT AND FRAME OK. | KYLEW | KYLEW | | HV | C | 6203531 |
PRECISION PLUMBING | P= | C | 07/30/2019 | Corrections made. | SAMH | SAMH | | P= | C | 6282385 |
PRECISION PLUMBING | P= | P | 07/26/2019 | Need trap loop at water heater condensate drain hose. Rest ok. Note: Laundry and bar sinks rough in only. PVB installed. | SAMH | SAMH | | P= | P | 6278187 |
PRECISION PLUMBING | PTO | C | 05/23/2019 | VTR, AAV at bar, Finished basement, Irrigation stub. | SAMH | SAMH | | PTO | C | 6208442 |
PRECISION PLUMBING | PB | C | 05/02/2019 | | SAMH | SAMH | | PB | C | 6185115 |