COLORADO STRUCTURES INC | B= | C | 09/04/2019 | | BOBF | BOBF | | B= | C | 6323379 |
COLORADO STRUCTURES INC | BFR | P | 07/29/2019 | pending other required inspections -hard lid framing in fitting rooms and rest rooms okay | BOBF | BOBF | | BFR | P | 6280745 |
COLORADO STRUCTURES INC | BFR | P | 07/09/2019 | pending completion of other required inspections / interior wall framing okay, hard lid framing in rest rooms okay / please note, plumbing rough in restroom is greater than 18" off side wall / Reviewed Accessible Elements / | BOBF | BOBF | | BFR | P | 6258003 |
ADVANCED ELECTRIC GROUP | E= | C | 08/21/2019 | | CRAIG | CRAIG | | E= | C | 6309527 |
ADVANCED ELECTRIC GROUP | EP | C | 08/20/2019 | panels ncr ----lb ---la ----ha---transformer OK | CRAIGS | CRAIGS | | EP | C | 6307147 |
ADVANCED ELECTRIC GROUP | E= | R | 08/20/2019 | gfci outlets 6' from the break area sink | CRAIGS | CRAIGS | | E= | R | 6307141 |
ADVANCED ELECTRIC GROUP | ER | P | 08/12/2019 | all except the inside entrance area | CRAIGS | CRAIGS | | ER | P | 6296504 |
ADVANCED ELECTRIC GROUP | ER | P | 08/08/2019 | main sales floor area OK | CRAIGS | CRAIGS | | ER | P | 6293759 |
COLORADO ELECTRICAL SYSTEMS, LLC | E= | C | 07/29/2019 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | E= | C | 6280648 |
COLORADO ELECTRICAL SYSTEMS, LLC | ER | C | 07/29/2019 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | ER | C | 6280647 |
ADVANCED ELECTRIC GROUP | ER | P | 07/29/2019 | hard lids OK | CRAIGS | CRAIGS | | ER | P | 6280635 |
ADVANCED ELECTRIC GROUP | ER | P | 07/09/2019 | walls and columns --- OK | CRAIGS | CRAIGS | | ER | P | 6257018 |
REEVES SPECIALTY SERVICES, INC. | H= | C | 09/03/2019 | | MARKB | MARKB | | H= | C | 6321388 |
ADVANCED MECHANICAL, LLC | H= | C | 08/30/2019 | REGULATOR VENTS COMPLETE | MARKB | MARKB | | H= | C | 6320992 |
ADVANCED MECHANICAL, LLC | HC | C | 08/30/2019 | RELEASE METER | MARKB | MARKB | | HC | C | 6320991 |
ADVANCED MECHANICAL, LLC | HI | C | 08/30/2019 | 10 PSI PRESSURE TEST OK. PIPING PER PLAN SPLICE. | MARKB | MARKB | | HI | C | 6320990 |
REEVES SPECIALTY SERVICES, INC. | H= | P | 08/30/2019 | FINAL PENDING - Review of test and balance report. VESTIBULE FLEX AND DIFFUSERS COMPLETE, SMOKE SHUT DOWN AND REMOTE INDICATORS CONFIRMED. TEST AND BALANCE REPORT RECEIVED. | MARKB | MARKB | | H= | P | 6320987 |
REEVES SPECIALTY SERVICES, INC. | H= | L | 08/26/2019 | No call ahead number provided. site locked | MARKB | MARKB | | H= | L | 6314796 |
ADVANCED MECHANICAL, LLC | HI | P | 08/22/2019 | ----Need to add unit heater and vent to permit--- ----Plan splice required - existing and new gas piping does not match plans---- Need a good 10 psi pressure test performed on a 30 psi gauge. Finish supports and medium pressure labels. Cannot use vent limiters outside - properly protect outdoor regulator vents. | MARKB | MARKB | | HI | P | 6311492 |
REEVES SPECIALTY SERVICES, INC. | HD | P | 08/13/2019 | -----Need a mechanical contractor to claim gas piping, unit heater and vent---- Need contractor to add 2 more exhaust fans and duct to permit. ABOVE CEILING DUCT - FLEX/DIFFUSERS COMPLETE BETWEEN GRID LINES C/J - 3.5/6 EXCEPT: Still need entery vestibule completed | MARKB | MARKB | | HD | P | 6299037 |
REEVES SPECIALTY SERVICES, INC. | HD | P | 07/10/2019 | NEED GAS CONTRACTOR ATTACHED TO PERMIT. FYI-- NORCO PLUMBING DOES NOT HAVE THE CORRECT LICENSE. NO ROOF, FLEX, DIFFUSERS, OR CONTROLS INSPECTED TODAY. ABOVE CEILING AND HARD LIDS IN BACK AREA OK (EF #1, #2, #3 AND A/C #2). ALL DAMPER HANDLES AT TAKE-OFFS ABOVE HARD LIDS TO BE FASTENED IN THE FULLY OPEN POSITION. RETAIL AREA-- DUCT WORK AND LATERALS OK TO CLOSE UP WRAP. COMPLETE ALL SUPPLY AND RETURN AIR DROPS. COMPLETE SOUTH SUPPLY AIR PIPING AT A/C #4 AND #5 | BILLS | BILLS | | HD | P | 6259490 |
NORCO PLUMBING LLC | P= | C | 08/30/2019 | Corrections made. | DANR | DANR | | P= | C | 6320001 |
NORCO PLUMBING LLC | PTO | C | 08/30/2019 | Ok. | DANR | DANR | | PTO | C | 6320000 |
NORCO PLUMBING LLC | P= | P | 08/26/2019 | Men's and women's accessible side clearances over 18 inches side walls / urinal lacking side clearances under 15 inches / need access to trap primer valves by restrooms / need check valve and isolation valve at water heater / need engineers letter for PVC pipe underground / need PTO complete / overhead inspection VTR | DANR | DANR | | P= | P | 6313718 |
NORCO PLUMBING LLC | PTO | P | 07/09/2019 | In wall DWV and domestic water inspection: Ok to insulate domestic water piping, need toilet flanges glued and anchored, need engineer letter from PB notes. Note: check trap primer access at final. | DANR | DANR | | PTO | P | 6257378 |
NORCO PLUMBING LLC | PTO | P | 06/24/2019 | domestic water in wall to both toilets ok. | DANR | DANR | | PTO | P | 6241421 |
NORCO PLUMBING LLC | PB | P | 06/13/2019 | Need engineers approval for PVC pipe underground. Design and test OK. Cover at own risk. | SAMH | SAMH | | PB | P | 6230303 |
REEVES SPECIALTY SERVICES, INC. | XMS | T | 08/28/2019 | PAID (REC#1626354) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: clouds only changed gas size | DALEH | DALEH | | XMS | T | 6316746 |