MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | B= | C | 10/27/2020 | All other required Final inspections are complete. (This is a computer generated result) | TIMOTHYS | TIMOTHYS | | B= | C | 6755587 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | B= | P | 10/14/2020 | Complete outside agency final inspections / Other items corrected. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | TIMOTHYS | TIMOTHYS | | B= | P | 6741628 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFR | C | 10/14/2020 | Received engineers letter for top plates in horizontal rated assemblies | TIMOTHYS | TIMOTHYS | | BFR | C | 6741627 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | B= | P | 10/09/2020 | Complete BFR / Complete outside agency final inspections / Unit 201 complies with 2003 ANSI Type B unit / Building final ok pending requirements listed -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | TIMOTHYS | TIMOTHYS | | B= | P | 6737020 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BIN | P | 10/09/2020 | Insulation complete pending completion of BFR | TIMOTHYS | TIMOTHYS | | BIN | P | 6736996 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFR | P | 10/09/2020 | Need to verify double top plates at rated horizontal assemblies via engineers letter or reinspection / Other items corrected | TIMOTHYS | TIMOTHYS | | BFR | P | 6736995 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFN | C | 10/09/2020 | | TIMOTHYS | TIMOTHYS | | BFN | C | 6736987 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFT | C | 10/09/2020 | Received engineers letter eliminating need for perimeter foundation drain | TIMOTHYS | TIMOTHYS | | BFT | C | 6736986 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 06/17/2020 | Front deck ledgers to be 16" oc / Rear deck frames ok | TIMOTHYS | TIMOTHYS | | BSP | P | 6607741 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BLA | C | 04/07/2020 | | TIMOTHYS | TIMOTHYS | | BLA | C | 6533575 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 04/03/2020 | Riser room framing ok | TIMOTHYS | TIMOTHYS | | BSP | P | 6531234 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 03/16/2020 | 2nd layer for all lids of units 101 and 201 OK per L583 / 2nd layer for stair towers OK per U308 listing / | NICK | NICK | | BSP | P | 6511738 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 03/09/2020 | Rock and rock attachment inspection / Stair enclosure U308 1st layer at walls and ceiling ok / UNIT 101: U303, U308 first layer, L583 first layer ok / UNIT 201: U303, U308 first layer, L583 first layer ok / UNIT 301: U303, U308 first layer ok / UNIT 401: U303 ok, U308 at stair enclosure screw pattern does not match listing requirements | TIMOTHYS | TIMOTHYS | | BSP | P | 6504320 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 03/04/2020 | Inspection for RC at lids of unit 101 and 201 / Crawl space penetrations OK for unit 201 / Dirt added into crawl space and height at 5' | NICK | NICK | | BSP | P | 6499737 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 02/28/2020 | All floor penetrations of units 401 and 301 OK / 5/8 rock for exterior rated wall of unit 401 OK behind tub | NICK | NICK | | BSP | P | 6496030 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 02/27/2020 | Penetrations for unit 101 and 102 OK / Still need to inspect penetrations for units 301 and 401 / Letters on file from architect for beam penetration in crawl space and for joist penetrations / Letter on file from architect for beam protection / All putty pads for electrical boxes OK | NICK | NICK | | BSP | P | 6494942 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BIN | P | 02/25/2020 | All wall and attic insulation OK / Still need to inspect all crawl space insulation | NICK | NICK | | BIN | P | 6491785 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 02/25/2020 | Pre rock for tubs at unit 301 and 101 OK, still need to inspect unit 401 pre rock for tub at exterior wall locations / Putty pads at unit 401 OK, still need to inspect putty pads for 101 unit / Need to inspect all penetrations for fire caulk | NICK | NICK | | BSP | P | 6491770 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 02/19/2020 | 1st layer of 5/8 type C for dead spaces at lids OK | NICK | NICK | | BSP | P | 6486209 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 02/18/2020 | RC and 1st layer of 5/8 type C sheet rock OK for pre rock areas of lids for dropped soffits | NICK | NICK | | BSP | P | 6484551 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFT | P | 02/13/2020 | Soils on file with approved plans / States to drain usable or entire if over ex done / Need drain or letter of observation for drain | NICK | NICK | | BFT | P | 6481720 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFR | R | 02/13/2020 | Need to install double top plates throughout at rated horizontal assemblies / Need to remove access to dead space at stairs for storage or splice into plans / Need Eng for cut in beam pocket for east side crawl space / West side crawl space at time of inspection is over 5' at 5'7" / Reviewed need for puddy pads at back to back boxes in rated walls / Need to install sheet rock behind tubs at exterior rated wall locations / Need to glue shims in beam pockets / Need to inspect all exterior decks / Need detail for joist penetrations of rated walls / Need detail for steel beam penetration of rated wall in crawl space on west side | NICK | NICK | | BFR | R | 6481713 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | R | 02/12/2020 | Inspection for pre rock of lids for restrooms / New listing per splice is M502 / 5/8 type X installed, need 5/8 type C per listing and need RC to be installed at 12" oc with insulation over top / Need to install double top plates for fir walls at restrooms | NICK | NICK | | BSP | R | 6480397 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 12/18/2019 | Inspection for units side rock per U308 at stairs in units 101 and 301 / 1st layer of 5/8 sheet rock OK per approved listing / Need detail from design professional for joist penetrations | NICK | NICK | | BSP | P | 6431268 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BIN | P | 12/18/2019 | Rock wool insulation installed for common walls at tub locations | NICK | NICK | | BIN | P | 6431251 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 12/06/2019 | Front porch lid framing for left side porch lid at roof OK per approved design / Still need to inspect all other exterior porches and deck frames | NICK | NICK | | BSP | P | 6419097 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 11/15/2019 | All exterior sheet rock per U303 for exterior walls OK / 1st and 2nd layer of 5/8 sheet rock OK per U308 OK for exterior walls of stair tower | NICK | NICK | | BSP | P | 6401013 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 11/11/2019 | Mineral wool insulation installed for parapet walls of back exterior rated walls per U303 / 1st layer of 5/8 type X OK for U308 wall at parapet wall on roof for stair tower / 2nd layer of 5/8 type X OK for parapet walls of stair tower / USG sheet rock OK for parapet wall of U303 walls | NICK | NICK | | BSP | P | 6394953 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 11/06/2019 | Met on site with Mike from Murphy / Need to install 5/8 type X rock for stair tower with screws at 8" oc per approved listing U308 / Need to install sheet rock in dead space of exterior stair tower where riser room installed / Need to install 3" mineral wool in U308 and U303 walls for exterior walls and in parapet sections / Reviewed need to pre rock dead spaces / Reviewed listed assemblies and need to print out listings and have on site | NICK | NICK | | BSP | P | 6390503 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFN | P | 11/06/2019 | 3rd party observation on file / Need footing complete / Foundation design on file with approved plans | NICK | NICK | | BFN | P | 6390502 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFT | P | 11/06/2019 | Open hole on file / Over ex observation on file / Open hole states to see soils for drain requirements, soils state to see open hole for drain requirements, need Eng showing foundation drain requirements / #2400psf / Density testing on file / 3rd party observation on file | NICK | NICK | | BFT | P | 6390501 |
JUST JENN INC | E= | C | 08/07/2020 | ok per pics | BRIAN | BRIAN | | E= | C | 6664548 |
JUST JENN INC | E= | P | 07/30/2020 | 301,401: porch outlets won't reset, ok to use WR outlet, has af/gf cb/ everything else,ok, Pics ok, upload images with next inspection request. If you encounter problems uploading images, please contact IT at 799-2688 / only house panel has above 10K aic, has 22k main, series rated,ok | JOHNN | JOHNN | | E= | P | 6656577 |
JUST JENN INC | E= | P | 07/13/2020 | 101: crawler needs guards on lights/ 20 amp a/c cb, did not check on roof for this one/ check cb's for 22K per previous notes/ 201: need guards on crawler lights/ need ADA hood, can not modify wiring unless listed for it/ gfci outlet within 6' of kitchen sink/ 20 amp a/c,ok/ 401: RTU: 26/30, min/max amps, | JOHNN | JOHNN | | E= | P | 6635037 |
COLORADO ELECTRICAL SYSTEMS, LLC | E= | C | 06/15/2020 | FIRE ALARM INSPECTION: | JOHNN | JOHNN | | E= | C | 6603897 |
COLORADO ELECTRICAL SYSTEMS, LLC | ER | C | 06/15/2020 | FIRE ALARM INSPECTION: | JOHNN | JOHNN | | ER | C | 6603896 |
COLORADO ELECTRICAL SYSTEMS, LLC | E= | P | 06/01/2020 | FIRE ALARM INSPECTION: strap flex in mech room within 12" of each box/ send pic/ | JOHNN | JOHNN | | E= | P | 6589531 |
COLORADO ELECTRICAL SYSTEMS, LLC | ER | C | 06/01/2020 | FIRE ALARM INSPECTION: | JOHNN | JOHNN | | ER | C | 6589530 |
JUST JENN INC | ER | C | 02/11/2020 | 301,401, complete, common area's, complete, | JOHNN | JOHNN | | ER | C | 6479280 |
COLORADO ELECTRICAL SYSTEMS, LLC | ER | P | 02/05/2020 | FIRE ALARM INSPECTION: all 4 units,ok, FA panel not installed , will go in front mech closet, | JOHNN | JOHNN | | ER | P | 6474251 |
JUST JENN INC | ES | P | 01/16/2020 | Commercial Service: 600 amp,3w, new commercial, ok to set meter: 101,201,301,401,house panel,------------------checked up to main outside, some feeders inside not made up yet, CHECK on final: label 17.2K AIC at house panel, and check for 22K branch cb's, | JOHNN | JOHNN | | ES | P | 6454901 |
JUST JENN INC | ES | R | 01/14/2020 | Commercial Service: 600 amp,3w, brass tags need match page A1,A2, label AIC in house panel,only one that is above 10K, --------------rev ufer in crawler,ok, water pipe not installed yet, CHECK later, some sub panel feeders not made up yet, | JOHNN | JOHNN | | ES | R | 6452100 |
JUST JENN INC | ER | P | 01/14/2020 | 201 rough,complete--------201 is main level unit per plan, | JOHNN | JOHNN | | ER | P | 6452016 |
JUST JENN INC | ER | R | 01/06/2020 | 101: rough,ok, check crawler on final, 201: hood needs accessible controls, add another sw/lg, lower sub panel to 48" to top cb, check crawler on final, Discussed accessibility requirements with contractor / | JOHNN | JOHNN | | ER | R | 6444335 |
JUST JENN INC | ER | R | 12/27/2019 | need the bath fans installed / need 20 amp 120 volt washer circuit installed / | BRIAN | BRIAN | | ER | R | 6438450 |
JUST JENN INC | ER | L | 12/13/2019 | consult with EC, discussed accessibility, only main floor unit is type B, | JOHNN | JOHNN | | ER | L | 6427539 |
GREEN PLUMBING | H= | C | 10/07/2020 | GAS CONNECTIONS COMPLETE, SEE IMAGES | BENH | BENH | | H= | C | 6732356 |
AIRTECH MECHANICAL, INC. | H= | C | 10/02/2020 | | JERRYF | JERRYF | | H= | C | 6727894 |
GREEN PLUMBING | H= | P | 10/02/2020 | PARTIAL PENDING CONTRACTOR CALLING H= INSPECTION AND ATTACHING PICTURES OF GAS CONNECTIONS | JERRYF | JERRYF | | H= | P | 6727891 |
GREEN PLUMBING | HC | C | 10/02/2020 | OK FOR METER RELEASE | JERRYF | JERRYF | | HC | C | 6727887 |
AIRTECH MECHANICAL, INC. | H= | L | 10/01/2020 | CANCELED BY CONTRACTOR AT CALL AHEAD - AT NEXT INSPECTION VERIFY THAT CORRECT RETURN AIR GRILLES ARE INSTALLED AT FLOOR RETURNS | JERRYF | JERRYF | | H= | L | 6726703 |
GREEN PLUMBING | H= | L | 09/11/2020 | CANCELED AT CALL AHEAD BY CONTRACTOR - CONTRACTOR WILL HAVE LADDER IN PLACE FOR ACCESS TO ROOF AT FUTURE INSPECTION | JERRYF | JERRYF | | H= | L | 6703263 |
GREEN PLUMBING | H= | P | 09/11/2020 | KITCHEN COUNTER LETTER RECEIVED AND FORWARDED TO BUILDING INSPECTOR | JERRYF | JERRYF | | H= | P | 6702255 |
AIRTECH MECHANICAL, INC. | H= | P | 09/08/2020 | APPROVED EQUIPMENT SUBMITTAL RECEIVED | JERRYF | JERRYF | | H= | P | 6698245 |
AIRTECH MECHANICAL, INC. | H= | P | 09/02/2020 | NEED THE FOLLOWING - APPROVED EQUIPMENT SUBMITTAL PER PREVIOUS NOTES - SUPPORT ENDS OF SUPPLY PLENUM'S IN CRAWLSPACE - COMPLETE CONDENSATE PUMP DRAINS TO APPROVED LOCATIONS - HOW IS CRAWLSPACE BEING CONDITIONED - INSPECTOR TO VERIFY BACK DRAFT AT CRAWLSPACE UNITS AT NEXT INSPECTION - UNDER CUT ALL BEDROOM DOORS FOR RETURN AIR PATH - NEED REQUIRED CLEARANCE TO BOTH FRESH AIR INTAKES FROM PLUMBING VENTS ON ROOF AT BOTH RTU'S - TAG ALL EQUIPMENT ON ROOF WITH PAINT MAKER OR LABEL TO UNITS SERVED | JERRYF | JERRYF | | H= | P | 6694596 |
AIRTECH MECHANICAL, INC. | HRP | C | 09/02/2020 | PRESSURE TESTS OK ON 2 LINE SETS | JERRYF | JERRYF | | HRP | C | 6694585 |
AIRTECH MECHANICAL, INC. | HD | C | 02/28/2020 | ABOVE CEILING SA / RA AND EXHAUST OK PER REVISED PLAN BDA PAGES 86 AND 87 | JERRYF | JERRYF | | HD | C | 6496370 |
AIRTECH MECHANICAL, INC. | HSP | P | 02/03/2020 | CHANGED INSPECTION TO HSP FOR CONSULT WITH WALT FROM AIR TECH AND G.C ON BATH FANS IN RATED FLOOR CEILING ASSEMBLY ON 1ST FLOOR UNITS - ENGINEER TO ADDRESS | JERRYF | JERRYF | | HSP | P | 6472300 |
GREEN PLUMBING | HI | C | 01/17/2020 | NOTE / 3/4 INCH MAIN / 2 RTU'S/2 FURNACES/ PER PLAN | DAVIDH | DAVIDH | | HI | C | 6456745 |
AIRTECH MECHANICAL, INC. | HSP | P | 01/14/2020 | AFTER REVIEW OF PLANS - ENGINEER NEEDS TO ADDRESS HOW PROTECTING BATH FAN OPENINGS IN RATED CEILING | JERRYF | JERRYF | | HSP | P | 6451924 |
AIRTECH MECHANICAL, INC. | HV | P | 01/13/2020 | CRAWLSPACE FURNACE VENTS DO NOT APPEAR TO BE PROPERLY SEATED IN FITTINGS - NEED TO REPLACE VENTS OR PRESSURE TEST- VENT BROKEN IN NORTH CRAWLSPACE APPEARS NO GLUE WAS USED??? - PROPERLY SUPPORT ALL VENTS PER INSTALL MANUAL - STOPPED INSPECTION - RE INSPECT ALL | JERRYF | JERRYF | | HV | P | 6451231 |
AIRTECH MECHANICAL, INC. | HD | P | 01/13/2020 | PARTIAL LIST - PROPERLY SUPPORT ALL FLEX IN BOTH CRAWLSPACE'S - NEED LINE SETS INSTALLED TO CRAWLSPACE UNITS - NEED APPROVED EQUIPMENT SUBMITTAL FOR ALL CARRIER EQUIPMENT - NEED CONSULT WITH BUILDING INSPECTOR ON BATH FANS IN LOWER LEVEL BATHROOMS AT RATED CEILINGS AND MAY NEED TO REPLACE ALL BATH FAN FLEX WITH HARD PIPE - 2ND FLOOR RETURN CHOKED IN SOUTH UNIT - NEED ALL ROOF CAPS BY FINAL - COULD NOT LOCATE BACK DRAFT DAMPERS AT OSA AIRS ON BOTH CRAWLSPACE'S - STOPPED INSPECTION RE INSPECT ALL | JERRYF | JERRYF | | HD | P | 6451221 |
AIRTECH MECHANICAL, INC. | HSP | P | 09/24/2019 | HAD CONSULT WALT FROM AIR TECH AND GC ON RATED SHAFT FOR BATH FAN AND RANGE HOOD VENTS - NEED ARCHITECT AND ENGINEER TO ADDRESS HOW PROTECTING PENETRATIONS OR RELOCATING VENTS | JERRYF | JERRYF | | HSP | P | 6346177 |
GREEN PLUMBING | P= | C | 09/25/2020 | | SAMH | SAMH | | P= | C | 6720080 |
GREEN PLUMBING | P= | P | 09/02/2020 | Kitchen sink in unit 201 is higher then 34" above finished floor. Note: See images for Engineers letter. | SAMH | SAMH | | P= | P | 6694421 |
GREEN PLUMBING | P= | P | 08/17/2020 | Kitchen sink height exceeds 34" in unit 201, Can not run 3/4" pex for T&P drains in all units. Need Engineers letter for AAV as previously noted. | SAMH | SAMH | | P= | P | 6675560 |
GREEN PLUMBING | P= | R | 07/30/2020 | Too many items to list in all units. Waive trip fee last time. | SAMH | SAMH | | P= | R | 6655834 |
GREEN PLUMBING | P= | P | 07/14/2020 | No water to units / trip fee waived this time. | DANR | DANR | | P= | P | 6636693 |
GREEN PLUMBING | P= | L | 07/10/2020 | Building locked. Call ahead completed at 9:55am. Site left at 10:28am. | SAMH | SAMH | | P= | L | 6633300 |
GREEN PLUMBING | PTO | C | 01/24/2020 | need engineers letter for aav's, no water heaters installed at this time | JOEL | JOEL | | PTO | C | 6463062 |
GREEN PLUMBING | PTO | P | 01/21/2020 | 2 traps on one trap arm @ main level unit, need roof access for vents, rest ok
still need main water stubbed in | JOHNS | JOHNS | | PTO | P | 6458526 |
GREEN PLUMBING | PTO | P | 01/17/2020 | ok for domestic waters only from water entry to units only, MINUS main water not stubbed in yet
still need dwv and accessible measurements
NOTE: hanging base, crawl space, vtr, aav (x2) in west crawl space, aav (x1) in east crawl space, aav @ both lower units laundry's (up high in wall w/ louvered panel @ final) check water htrs and water entry @ final | JOHNS | JOHNS | | PTO | P | 6457036 |
AIRTECH MECHANICAL, INC. | XMS | T | 01/03/2020 | PAID (REC#1654507) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: new splice changed vented hoods to vent less hoods . rerouted ducts, | TCRIPPEN | TCRIPPEN | | XMS | T | 6442962 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | XBS | T | 12/18/2019 | PAID (REC#1654508) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Revised chases; clarify listed assemblies; and crawlspace vents removed | SHELLEY | SHELLEY | | XBS | T | 6430943 |