HOMEOWNER | BFI | C | 04/26/2023 | Observed insulation in crawlspace | DOUGC | DOUGC | | BFI | C | 7727669 |
HOMEOWNER | BE | P | 10/28/2022 | | JACKIEP | JACKIEP | | BE | P | 7566582 |
HOMEOWNER | BE | P | 05/04/2022 | | MATTHEWM | MATTHEWM | | BE | P | 7363468 |
HOMEOWNER | BIN | C | 11/03/2021 | | NATHAN | NATHAN | | BIN | C | 7164517 |
HOMEOWNER | BFR | C | 11/03/2021 | Items corrected. | NATHAN | NATHAN | | BFR | C | 7164516 |
HOMEOWNER | BFR | P | 11/03/2021 | engineer letter for headers, joists and beam support on file. | NATHAN | NATHAN | | BFR | P | 7163585 |
HOMEOWNER | BFR | P | 10/04/2021 | still need basement post instead of beam pocket corrected and added basement window / need bearing block at T06X / crawlspace 2 cut joists under center full bath / block garage door brackets / add diagonal brace and over lap lateral by 1 truss at T03A and T03B / | NATHAN | NATHAN | | BFR | P | 7129245 |
HOMEOWNER | BFD | C | 09/15/2021 | | NATHAN | NATHAN | | BFD | C | 7108676 |
HOMEOWNER | BFR | R | 09/15/2021 | Remove all personal items from garage for inspections / T09F truss missing post, bearing block and hardware at wall / TO6 A-H trusses missing 2 H2.5T / seal all penetrations at top and bottom plates and firestops / missing HTS24 at TO3C and D trusses / missing connectors in HGUS210-3 at girders / need T01 A t bracing trusses do not match design and need as built details on site / missing 2 trimmers at rear basement headers left of stairs / east beams ends not in foundation no call out for posts / missing large point load at garage side front girder / window in west basement bedroom not on plans / =========== inspection stopped need trusses, crawlspace and garage inspected still . ============ | NATHAN | NATHAN | | BFR | R | 7108665 |
HOMEOWNER | BSP | P | 08/13/2021 | roll block at rear deck drop beams / check rear deck steps not installed / check at frame | CHRISTYB | CHRISTYB | | BSP | P | 7072390 |
HOMEOWNER | BSP | P | 12/21/2020 | front porch roof and posts, rear deck roof and posts only okay | NATHAN | NATHAN | | BSP | P | 6815694 |
HOMEOWNER | BLA | C | 12/21/2020 | | NATHAN | NATHAN | | BLA | C | 6815686 |
HOMEOWNER | BFN | C | 10/12/2020 | soils and open hole report on file. | NATHAN | NATHAN | | BFN | C | 6737283 |
HOMEOWNER | BFD | P | 08/19/2020 | still need soils and openex paperwork, drain is daylighted to south sides of home | NATHAN | NATHAN | | BFD | P | 6678543 |
HOMEOWNER | BFN | P | 02/19/2020 | soils and stamped openex needed, remaining paperwork on file | NATHAN | NATHAN | | BFN | P | 6486244 |
HOMEOWNER | BFT | C | 10/22/2019 | Engineer letter for micropiles received / | NATHAN | NATHAN | | BFT | C | 6375992 |
HOMEOWNER | BFT | P | 10/10/2019 | stamped observation letter from micropile installation needed, plan for layout and design on file | NATHAN | NATHAN | | BFT | P | 6364236 |
HOMEOWNER | BFD | P | 10/09/2019 | drain is usable to daylight at SE and SW corners | NATHAN | NATHAN | | BFD | P | 6363505 |
HOMEOWNER | BFN | P | 10/09/2019 | foundation wall observation only, piers observation and tie beam observation needed. | NATHAN | NATHAN | | BFN | P | 6362723 |
HOMEOWNER | BFT | R | 06/18/2019 | No footing forms in place for inspection at time of site visit / Called and left message with homeowner / Gave OK for 3rd party observations if wanted / Need 3rd party observations for helical piers / | NICK | NICK | | BFT | R | 6235120 |
HOMEOWNER | E= | R | 12/13/2023 | GFCI protect garage door openers, dishwasher /disposal x2, guest bath / faulty smoke and basement laundry breakers / 50A steam shower / hot tub pre-wire and future 50A garage outlets / | MIGUEL | MIGUEL | | E= | R | 7944694 |
HOMEOWNER | E= | R | 12/13/2023 | GFCI protect garage door openers, dishwasher /disposal x2, guest bath / faulty smoke and basement laundry breakers / 50A steam shower / hot tub pre-wire and future 50A garage outlets / | MIGUEL | MIGUEL | | E= | R | 7944695 |
HOMEOWNER | EP | C | 10/23/2023 | 3 sub panels--ok / | BRIAN | BRIAN | | EP | C | 7896412 |
HOMEOWNER | ES | C | 10/23/2023 | Residential Underground: 320 amp 3-w---ok no action needed by csu / | BRIAN | BRIAN | | ES | C | 7896411 |
HOMEOWNER | ER | C | 07/29/2021 | corrections made / each bathroom has own dedicated 20A circuit for power and lighting / | MIGUEL | MIGUEL | | ER | C | 7053704 |
HOMEOWNER | ER | R | 07/27/2021 | basement 2 bathrooms and laundry sharing 20A circuit / wall spacing at main level sliders and upper and lower fireplaces / make fireplace connections x2 / 6-#6 CU / #1 CU sub / reversible ufer connection / no MCCS / finished basement / Discussed AFCI/GFCI/TR requirements with owner. / | MIGUEL | MIGUEL | | ER | R | 7051012 |
HOMEOWNER | ES | P | 03/24/2021 | Residential Underground: 320A 3w new res ok to set meter / RBD note : up to main only / will need #2 CU to copper cold water / | MIGUEL | MIGUEL | | ES | P | 6909279 |
HOMEOWNER | H= | C | 12/13/2023 | NOTE: FINISHED BASEMENT / RADIANT HEAT / OSA VENTILATION SYSTEM IN CRAWL SPACE AS PER PLANS | MICHAELM | MICHAELM | | H= | C | 7944576 |
HOMEOWNER | H= | P | 10/23/2023 | Provide installation instructions for heat pumps / Remove screen from upper level dryer exhaust termination / Heat pumps running domestic hot water and radiant heat / NOTE / Conditioned crawlspace / Finished basement / Radiant heat / Outside air ventilation system as per plans / Gas line in mechanical room for future use / | CASEYM | CASEYM | | H= | P | 7896469 |
HOMEOWNER | HC | C | 09/14/2021 | RELEASE METER | BILLS | BILLS | | HC | C | 7106836 |
HOMEOWNER | HI | C | 09/14/2021 | 10 LB TEST OK / 1-1/2 INCH MAIN / 1 BOILER (FUTURE USE) / 1 COOK TOP / 2 FIREPLACES / 1 BBQ / | BILLS | BILLS | | HI | C | 7106804 |
HOMEOWNER | HSP | P | 09/07/2021 | WILL NEED A HI INSPECTION FOR ANY GAS LINES INSTALLED | MICHAELM | MICHAELM | | HSP | P | 7098277 |
HOMEOWNER | HWP | C | 09/07/2021 | 70 LB TEST OK / UPPER AND LOWER LEVEL OK / OK TO COVER | MICHAELM | MICHAELM | | HWP | C | 7098255 |
HOMEOWNER | HRR | C | 09/07/2021 | NOTE: FINISHED BASEMENT / RADIANT HEAT / OSA VENTILATION SYSTEM AS PER PLANS | MICHAELM | MICHAELM | | HRR | C | 7098254 |
HOMEOWNER | HRR | P | 09/02/2021 | 9-3-21 Updated notes; Will need to get the new heating system approved through plan review ASAP / The use of a booster fan will not be allowed, must increase the duct to 5 inch from fan through the termination / THE 4 INCH FLEX FOR THE MAIN LEVEL BATH IS UNDERSIZED FOR THE 110 CFM / Will need to research the use of a booster fan for the 120 CFM bath exhaust in basement half bath / Will need to speak to senior inspector about the OSA system / Will need to research on the ChilTrex heat pump system / Will update notes in AM / | MICHAELM | MICHAELM | | HRR | P | 7095657 |
FIREPLACE WAREHOUSE | HV | C | 08/25/2021 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / BASEMENT FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / | MICHAELM | MICHAELM | | HV | C | 7084937 |
HOMEOWNER | P= | P | 12/13/2023 | Still Need Information On Side Arm - Homeowner To Email Info
Rest Of Corrections OK
Note: 3/4 RP | TRAVISR | TRAVISR | | P= | P | 7944145 |
HOMEOWNER | P= | P | 10/23/2023 | Need Hammer Arrestor @ Both Dishwasher All Toilets @ main Level Loose Need Install Instructions On Side Arm ( No Stickers Or Information Listed ) Need Trap Seal @ Both Basement Floor Drains Can Not Use Dual Check As Backflow Protection @ Irrigation Stub Rest OK
| TRAVISR | TRAVISR | | P= | P | 7896051 |
HOMEOWNER | PTO | C | 08/18/2021 | Corrections completed | FRANKM | FRANKM | | PTO | C | 7076967 |
HOMEOWNER | PTO | P | 08/16/2021 | 3" DWV required when wash machine branch ties into other fixture branches (2) Note : AAV in attic above garage / AAV @ butler sink / AAV @ vegetable sink / AAV @ washer box adjacent to mech room / AAV @ basement laundry sink / AAV @ main level laundry sink / AAV @ steamer unit drain / AAV @ KC drain / AAV @ basement bath 1 - VTR check water entry & water heater piping @ final / check washer box shock arrestors @ final | FRANKM | FRANKM | | PTO | P | 7073732 |
HOMEOWNER | PTO | P | 08/13/2021 | Field cancel | FRANKM | FRANKM | | PTO | P | 7071927 |
HOMEOWNER | PB | C | 09/30/2019 | ok for drain stubs / crawl space drain (will be hanging base @ pto), will check water stub in under footer @ pto
check water stub in @ pto, by pto need back water trap @ crawl space, 4" bldg drain = 2" vtr @ pto, 2011 pprbc | JOHNS | JOHNS | | PB | C | 6352145 |
HOMEOWNER | XBS | T | 11/03/2021 | PAID (REC#1864143) PLAN SPLICE FEE: $50 by: LBENNETT for Construction: E-ltr for windows and steel columns | LBENNETT | LBENNETT | | XBS | T | 7164340 |
HOMEOWNER | XBS | T | 08/02/2021 | PAID (REC#1798220) PLAN SPLICE FEE: $50 by: LBENNETT for Construction: Framing detail for front porch, and for extension to the west end of the existing back deck. | LBENNETT | LBENNETT | | XBS | T | 7056876 |
HOMEOWNER | XMS | P | 10/16/2020 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Added equipment sheets | JUSTINC | JUSTINC | | XMS | P | 6744795 |