WELLS & WEST GENERAL CONTRACTORS, INC. | B= | C | 02/19/2020 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 6486002 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 09/30/2019 | final OK pending other finals. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | P | 6352495 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 07/17/2019 | Need to attach mechanical permit -- New light gauge framed walls OK -- Reviewed Accessible Elements | DAKOTAB | DAKOTAB | | BFR | P | 6267269 |
PROCOM ELECTRICAL SERVICES, INC. | E= | C | 02/19/2020 | FIRE ALARM INSPECTION: | BRET | BRET | | E= | C | 6486001 |
PROCOM ELECTRICAL SERVICES, INC. | ER | C | 02/19/2020 | one device | BRET | BRET | | ER | C | 6486000 |
PROCOM ELECTRICAL SERVICES, INC. | EE | L | 02/12/2020 | Renewed for No Fee at 2/12/2020 10:53:40 AM | TERRI | TERRI | | EE | L | 6480072 |
PROCOM ELECTRICAL SERVICES, INC. | E= | C | 08/15/2019 | | BRET | BRET | | E= | C | 6302198 |
PROCOM ELECTRICAL SERVICES, INC. | E= | P | 08/13/2019 | second support for track lights, updated panel schedule | BRET | BRET | | E= | P | 6298526 |
PROCOM ELECTRICAL SERVICES, INC. | E= | C | 08/13/2019 | | BRET | BRET | | E= | C | 6298522 |
PROCOM ELECTRICAL SERVICES, INC. | ER | C | 08/13/2019 | | BRET | BRET | | ER | C | 6298518 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 08/12/2019 | install 2nd support at all track light location rest of ceiling ok | BRET | BRET | | ER | P | 6296636 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 07/16/2019 | walls only | RANDY | RANDY | | ER | P | 6264639 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 09/17/2019 | TEST AND BALANCE REPORT RECEIVED, SEE IMAGES. MECHANICAL FINAL OK. | DUSTINS | DUSTINS | | H= | C | 6337387 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 08/22/2019 | TEST AND BALANCE REPORT RECEIVED, SEE IMAGES. TEST AND BALANCE REPORT NEEDS TO BE DONE BY A CERTIFIED TEST AND BALANCE COMPANY, ALSO TAB SHOWS NO READINGS FOR VAV-2, VAV-5, VAV-6, VAV-7, VAV-8 (SEE NOTE 2 ON PLANS) AND NO OUTSIDE AIR READING. STILL NEED TO VERIFY RELOCATED THERMOSTAT. | DUSTINS | DUSTINS | | H= | P | 6309928 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 07/29/2019 | FOR FINAL NEED TO SEE THE RELOCATED THERMOSTAT BEHIND RECEPTION 381, SEE NOTE 6 ON PLAN AND MOUNT NO HIGHER THAN 48" ABOVE FINISHED FLOOR. PROVIDE TEST AND BALANCE REPORT. | DUSTINS | DUSTINS | | H= | P | 6279520 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | C | 07/25/2019 | NEW AND RELOCATED SUPPLY AIR DUCTS ABOVE CEILING OK. OK TO WRAP. FOR FINAL NEED TO SEE THE RELOCATED THERMOSTAT BEHIND RECEPTION 381, SEE NOTE 6 ON PLAN AND MOUNT NO HIGHER THAN 48" ABOVE FINISHED FLOOR. PROVIDE TEST AND BALANCE REPORT. | DUSTINS | DUSTINS | | HD | C | 6277071 |