SEEGER HOMES, INC | B= | C | 12/30/2020 | | JASONL | JASONL | | B= | C | 6822198 |
SEEGER HOMES, INC | BSP | P | 12/29/2020 | ES report for DC315 on file / DC315 install cert on file / Spray foam installers cert on file | CHAD | CHAD | | BSP | P | 6820677 |
SEEGER HOMES, INC | BSP | P | 12/22/2020 | ES report on file for spray foam used. Will need test report for DC315 ignition barrier and installers certs for both spray foam and DC315 products / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file. | CHUCK | CHUCK | | BSP | P | 6816081 |
SEEGER HOMES, INC | B= | P | 12/21/2020 | No inspection performed - Need to upload ES report for spray foam noted in previous B= to determine if thermal or ignition barrier is required as well as conditions of use / Need to Provide Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 to inspection request. -- Schedule a new Building Final when above items are complete. | JUSTINL | JUSTINL | | B= | P | 6815751 |
SEEGER HOMES, INC | B= | P | 10/29/2020 | Need to provide evaluation report for spray foam insulation used in attic / / Smoke and co detectors on main level not working / Provide Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 / Unfinished attic and basement, no deck -- Schedule a new Building Final when above items are complete. / Update TP Insignia # 2019-3112 | TRENTP | TRENTP | | B= | P | 6758493 |
SEEGER HOMES, INC | BFR | C | 10/01/2020 | LVL okay per discussion with Nathan R that there is continuous bearing under LVL / Engineering for collar ties on file / Frame okay | TRENTP | TRENTP | | BFR | C | 6725707 |
SEEGER HOMES, INC | BFR | R | 07/28/2020 | Collar ties still notched at dormer, will need engineer letter for clarification if repair is needed / Notches still present at marriage line LVL, need clarification from engineer is repair is needed / Marriage line straps and collar tie nailing okay | TRENTP | TRENTP | | BFR | R | 6652812 |
SEEGER HOMES, INC | BFR | R | 07/20/2020 | No corrections made for house frame items / No previous confirmation of LSTA straps at marriage line for trusses / Garage items corrected | TRENTP | TRENTP | | BFR | R | 6643211 |
SEEGER HOMES, INC | BFR | P | 03/30/2020 | Garage Frame - Missing drywall protection under doorway from garage-house / Door from garage-house to be a min. 20 min. fire rated or a min. 1 3/8" thick // Sill anchors and truss bottom chord bracing installed. House Frame - Nail collar ties per engineering detail / Manufactured collar ties notched at dormer / Unable to verify LSTA30 straps from trusses to marriage line beam in attic due to installation of floor sheathing / 3.5" notches made in LVL marriage line beam in basement // Rest of frame OK. | CHUCK | CHUCK | | BFR | P | 6525985 |
SEEGER HOMES, INC | BSP | R | 02/05/2020 | Additional bottom chord bracing required if rigid ceiling is not applied / Fire blocking of top plate penetrations required if enclosing wall cavities/installing drywall ceiling / Will need to verify garage-dwelling separation // Rest of garage frame OK. | CHUCK | CHUCK | | BSP | R | 6474439 |
SEEGER HOMES, INC | BTD | C | 12/11/2019 | Serial# 17-M33262 - Insignia affixed to electric panel | TIMOTHYS | TIMOTHYS | | BTD | C | 6424791 |
SEEGER HOMES, INC | BFI | C | 10/09/2019 | R10 installed / | DALE | DALE | | BFI | C | 6363392 |
SEEGER HOMES, INC | BFD | C | 10/09/2019 | drain daylighted / damp proofing ok | DALE | DALE | | BFD | C | 6363383 |
SEEGER HOMES, INC | BFN | C | 10/01/2019 | Steel reinforcement for foundation walls ok per plan | TIMOTHYS | TIMOTHYS | | BFN | C | 6354291 |
SEEGER HOMES, INC | BFT | C | 09/18/2019 | Steel reinforcement for footing ok per plan | TIMOTHYS | TIMOTHYS | | BFT | C | 6340065 |
SEEGER HOMES, INC | BFT | P | 09/18/2019 | Soils report on file - 3500# (matches open ex./2600# design) / 5% / usable drain required // Need to complete BFT. | CHUCK | CHUCK | | BFT | P | 6338840 |
SEEGER HOMES, INC | BFT | R | 09/17/2019 | Not ready, steel reinforcement not complete per plan | TIMOTHYS | TIMOTHYS | | BFT | R | 6337572 |
SEEGER HOMES, INC | BFT | P | 09/17/2019 | Open ex. observation on file - need soils report. | CHUCK | CHUCK | | BFT | P | 6337217 |
LAKE STAR ELECTRIC, INC. | E= | C | 03/27/2020 | | TOMC | TOMC | | E= | C | 6524080 |
LAKE STAR ELECTRIC, INC. | ES | C | 03/27/2020 | Residential Underground: 200-amp 3-wire service upgrade, no action required by utility. / METER NEEDS SEALED | TOMC | TOMC | | ES | C | 6524071 |
LAKE STAR ELECTRIC, INC. | ES | C | 03/27/2020 | Residential Underground: 200-amp 3-wire service upgrade, no action required by utility. / METER NEEDS SEALED | TOMC | TOMC | | ES | C | 6524070 |
LAKE STAR ELECTRIC, INC. | ER | C | 03/27/2020 | | TOMC | TOMC | | ER | C | 6524069 |
LAKE STAR ELECTRIC, INC. | ES | R | 03/26/2020 | see service and rough notes | TOMC | TOMC | | ES | R | 6522540 |
LAKE STAR ELECTRIC, INC. | ER | R | 03/26/2020 | need receptacle for each bay of garage / need to be trimmed out for final | TOMC | TOMC | | ER | R | 6522539 |
LAKE STAR ELECTRIC, INC. | E= | R | 03/26/2020 | see service and rough notes | TOMC | TOMC | | E= | R | 6522535 |
LAKE STAR ELECTRIC, INC. | ES | R | 03/26/2020 | Residential Underground: riser needs strapped , inter-system bond needs installed , j-box below panel needs to be accessible , panel door needs to open 90 degrees | TOMC | TOMC | | ES | R | 6522533 |
LAKE STAR ELECTRIC, INC. | ES | R | 01/24/2020 | Residential Underground: PROTECT SER CABLE IN GARAGE ------ | GREGM | GREGM | | ES | R | 6463646 |
LAKE STAR ELECTRIC, INC. | ER | R | 01/24/2020 | PROTECT SER CABLE IN GARAGE ----- REST OK ----- | GREGM | GREGM | | ER | R | 6463644 |
LAKE STAR ELECTRIC, INC. | EUG | C | 12/02/2019 | 4/0 urd | TOMC | TOMC | | EUG | C | 6413362 |
ALL SEASONS HEATING AND AIR CONDITIONING | H= | C | 03/23/2020 | WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN BASEMENT / WHOLE HOUSE VENTILATION SWITCH LOCATED IN BASEMENT
NOTE/UNFINISHED BASEMENT WITH TWO SUPPLIES AND ONE RETURN / DIRECT VENT FURNACE / ELECTRIC WATER HEATER / A/C rough, coil and lineset / | ANDREWP | ANDREWP | | H= | C | 6518248 |
R AND D PLUMBING | HSP | C | 02/04/2020 | PER CONVERSATION WITH CONTRACTOR METER WILL BE AT HOUSE AND NOT THE SIDE OF THE ROAD | ANDREWP | ANDREWP | | HSP | C | 6473121 |
ALL SEASONS HEATING AND AIR CONDITIONING | HC | C | 02/03/2020 | RELEASE METER | ANDREWP | ANDREWP | | HC | C | 6473122 |
ALL SEASONS HEATING AND AIR CONDITIONING | HRR | C | 02/03/2020 | WHOLE HOUSE VENTILATION BEING ACHIEVED WITH EXHAUST FAN LOCATED IN UNFINISHED BASEMENT / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / UNFINISHED BASEMENT / 2 SUPPLIES ,1 RETURN GRILL TO THE UP STAIRS/ DIRECT VENT FURNACE | ANDREWP | ANDREWP | | HRR | C | 6472394 |
R AND D PLUMBING | HI | C | 01/31/2020 | 10 LB TEST OK / 1 1/4 INCH MAIN / 1 FURNACE / 1 RANGE / | BENH | BENH | | HI | C | 6471021 |
R AND D PLUMBING | P= | C | 03/26/2020 | Potable Water Test received | MALYNDA | MALYNDA | | P= | C | 6521878 |
R AND D PLUMBING | P= | P | 03/23/2020 | Need potable water certificate, rest ok | MALYNDA | MALYNDA | | P= | P | 6517919 |
R AND D PLUMBING | PTO | C | 03/23/2020 | Note: unfinished basement | MALYNDA | MALYNDA | | PTO | C | 6517917 |
R AND D PLUMBING | PB | C | 11/14/2019 | | MALYNDA | MALYNDA | | PB | C | 6399044 |
HOMEOWNER | PWO | C | 11/07/2019 | Need Certificate of potable water by final. Pit OK. | SAMH | SAMH | | PWO | C | 6392034 |