SCHWERS CONSTRUCTION CO | B= | C | 04/01/2020 | Blower door on file | NICK | NICK | | B= | C | 6527532 |
SCHWERS CONSTRUCTION CO | B= | P | 03/04/2020 | Temp CO: Pending Fire/Zoning Finals ( Expires: 4/3/2020 12:00:00 AM) | MATTHEWM | MATTHEWM | | B= | P | 6500217 |
SCHWERS CONSTRUCTION CO | B= | P | 03/04/2020 | Provide Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 / All other items completed -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | P | 6500016 |
SCHWERS CONSTRUCTION CO | B= | R | 02/28/2020 | Still need Insulation cert and blower door cert / gap between ballister and newel at top of garage landing stairs is greater than 4" ( 5 1/2"). Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | BOBF | BOBF | | B= | R | 6496183 |
SCHWERS CONSTRUCTION CO | B= | R | 02/27/2020 | Need to install graspable hand rail for garage steps / Need to install guard at garage steps with no more than 4" openings / Need to install guard at stairs with no more than 6" sphere opening for steps at main stairs / Need to return hand rail at top and bottom of stairs for basement / Need to install guard rail for back patio where over 30" of fall occurs 36" out from standing surface / Need to provide blower door test / Need insulation certificate / 1/2" sheet rock installed at lids in basement. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | R | 6494572 |
SCHWERS CONSTRUCTION CO | B= | R | 02/25/2020 | All doors locked to house / No call ahead provided / Walked outside of house / Need to install 5" tall 1/2" stroke address numbers on house / Need to install all tip outs for down spouts / Need to install guard rail at back patio where over 30" of fall / Still need frame complete with splice of plans for added fire place. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | R | 6492152 |
SCHWERS CONSTRUCTION CO | BIN | P | 12/03/2019 | OK pending frame complete / Check attic at final / Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / | NICK | NICK | | BIN | P | 6414975 |
SCHWERS CONSTRUCTION CO | BFR | P | 12/03/2019 | Eng on file for stair LVL / Still need to splice plans for added fire place in family room / All other framing OK | NICK | NICK | | BFR | P | 6414959 |
SCHWERS CONSTRUCTION CO | BFD | C | 12/03/2019 | | NICK | NICK | | BFD | C | 6414957 |
SCHWERS CONSTRUCTION CO | BFN | C | 12/03/2019 | | NICK | NICK | | BFN | C | 6414953 |
SCHWERS CONSTRUCTION CO | BFT | C | 12/03/2019 | Revised open hole on file with #2500psf | NICK | NICK | | BFT | C | 6414949 |
SCHWERS CONSTRUCTION CO | BFR | R | 11/27/2019 | Still need Eng for stair stringer connection / Still need to splice plans for fire place in family room / Need footing/foundation complete / All other framing items completed | NICK | NICK | | BFR | R | 6411294 |
SCHWERS CONSTRUCTION CO | BFN | R | 11/27/2019 | Need footing complete with bearing of #2400 on open hole and #2500 for design / 3rd party observation on file for foundation/ufer | NICK | NICK | | BFN | R | 6411292 |
SCHWERS CONSTRUCTION CO | BFT | R | 11/27/2019 | Open hole shows bearing of #2400psf, foundation design is for #2500psf / Drain usable / 3rd party observation on file for footing/pads / Need 3rd party observation for exterior piers | NICK | NICK | | BFT | R | 6411289 |
SCHWERS CONSTRUCTION CO | BFR | R | 11/22/2019 | Still need 3rd party observations for footing/foundation / Still need open hole report / Need to install LS30's to tie balloon frame wall top plate to other walls / Need to install 2 MTS12 straps for AH11 girder main level / Need to splice plans to show fire place in family room / Need to glue shims in beam pockets / Need to install spikes in floating walls of basement bathroom / Need Eng for hanger used at LVL for stair stringers not on approved plans or bear on steel beam per approved plans / Reviewed need for 1/2" sheet rock of unfinished basement by final / Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / | NICK | NICK | | BFR | R | 6408694 |
SCHWERS CONSTRUCTION CO | BLA | C | 11/15/2019 | Lath ok | CHRISTINEH | CHRISTINEH | | BLA | C | 6401141 |
SCHWERS CONSTRUCTION CO | BSP | P | 10/21/2019 | Portal wall framing for garage OK / Front and back porches OK / ST22 straps OK per detail A / Eng on file for framing of back porch rafters / Still need open hole report / Still need 3rd party observation for footing/foundation / Foundation design on file with approved plans | NICK | NICK | | BSP | P | 6375442 |
SCHWERS CONSTRUCTION CO | BSP | R | 10/14/2019 | Need to install MTS12 strap for AH16 at front porch / Need double H2.5T for next to trusses front porch / Need Eng detail for rafter connection to trusses or exterior wall location at back porch framing / Need to install interior 1000lb straps for portal frame wall at garage / Need to inspect ST22 straps per detail A throughout / All other framing for front/back porch and garage portal frame wall OK / Still need open hole report, 3rd party observation footing/foundation and foundation design | NICK | NICK | | BSP | R | 6367295 |
SCHWERS CONSTRUCTION CO | BFD | P | 08/23/2019 | Drain of usable space OK / Damp proof OK / Drain daylights at south corner of house / Need 3rd party observation report for footing/foundation / Need foundation design and open hole report | NICK | NICK | | BFD | P | 6312429 |
SCHWERS CONSTRUCTION CO | BFT | P | 08/22/2019 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 6310381 |
SCHWERS CONSTRUCTION CO | BFN | P | 08/22/2019 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 6310380 |
MARCUS ELECTRIC LLC | E= | C | 02/21/2020 | corrections | CRAIGS | CRAIGS | | E= | C | 6488314 |
MARCUS ELECTRIC LLC | E= | R | 02/20/2020 | max a/c over current protection 35 amp its on a 40 --- disconnect is non fused --- min. 22 --- replace breaker and upload a picture | CRAIGS | CRAIGS | | E= | R | 6487050 |
MARCUS ELECTRIC LLC | E= | R | 02/13/2020 | range needs cb lock out, rear outside outlet needs gfci, master bath outlet within 6' of tub needs gfci, mount inter system bond terminal, basement horizonal nm cable needs blocking directly over top in between studs, no a/c yet, -----------------------basement has finished bath rm and all lid, rest unfinished. | JOHNN | JOHNN | | E= | R | 6481448 |
MARCUS ELECTRIC LLC | E= | L | 02/13/2020 | no lock box code, | JOHNN | JOHNN | | E= | L | 6481375 |
MARCUS ELECTRIC LLC | ER | C | 11/21/2019 | six bathrooms, no c-vac, no floor heat, sub panel okay, no mcc., expose ufer | GARYL | GARYL | | ER | C | 6407439 |
MARCUS ELECTRIC LLC | ES | C | 11/05/2019 | Residential Underground: New 200 amp service, need power to new residence | GARYL | GARYL | | ES | C | 6389046 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 02/19/2020 | NOTE/ WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / | DAVIDH | DAVIDH | | H= | C | 6486520 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 02/18/2020 | MISSING DAMPER IN RETURN AIR, NO WHOLE HOUSE FAN SWITCH INSTALLED OR LABELED AND BOTH BED ROOMS UPSTAIRS NEED PATH FOR RETURN AIR NEED UNDER CUT DOOR 1" OFF CARPET. NOTE DIRECT VENT FURNACE/, UN-FINISHED BASEMENT/ AC COMPLETE | DAVIDH | DAVIDH | | H= | P | 6485169 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 11/19/2019 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 6404686 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 11/19/2019 | note need damper installed in out side air by final . a/c coil only no line set . unfinished basement whole house fan tied in to furnace blower, direct vent furnace | DAVIDH | DAVIDH | | HRR | C | 6404678 |
FIREPLACE WAREHOUSE | HV | C | 11/18/2019 | 2 fireplaces Main level fireplace clearance to combustibles and vent termination ok. / | DAVIDH | DAVIDH | | HV | C | 6402728 |
KNAUF HEATING AND AIR CONDITIONING | HI | C | 11/18/2019 | 10 lb test ok note 1 1/4" main 1 furnace,range,2 fireplaces,2 water heaters | DAVIDH | DAVIDH | | HI | C | 6402718 |
TIMBERWOLF PLUMBING, INC. | P= | C | 02/05/2020 | partial finished bsmnt (only bath finishes @ this time), no irrigation stub | JOHNS | JOHNS | | P= | C | 6474254 |
TIMBERWOLF PLUMBING, INC. | PTO | C | 11/22/2019 | Corrections made. | SAMH | SAMH | | PTO | C | 6407918 |
TIMBERWOLF PLUMBING, INC. | PTO | P | 11/19/2019 | Insulate hot water lines per IECC prescriptive method. Rest OK. Note: VTR, AAV at laundry sink, both master lavs, and basement lav. CWV at upper level hall bath, Mixing valve at right master lav. Check meter loop at final. | SAMH | SAMH | | PTO | P | 6403944 |
TIMBERWOLF PLUMBING, INC. | PB | C | 09/03/2019 | | DANR | DANR | | PB | C | 6322606 |
HOMEOWNER | PWO | L | 08/14/2019 | Wrong inspection called. | SAMH | SAMH | | PWO | L | 6299843 |