CENTURY CONSTRUCTION & SONS LTD. | B= | C | 11/20/2020 | | TRENTP | TRENTP | | B= | C | 6784519 |
CENTURY CONSTRUCTION & SONS LTD. | BLA | C | 11/20/2019 | | TIMOTHYS | TIMOTHYS | | BLA | C | 6406352 |
CENTURY CONSTRUCTION & SONS LTD. | BFN | C | 11/12/2019 | Open hole received - 1500 psf - Drain around habitable space - Drain designs on file - 5% grade | ASHLEYB | ASHLEYB | | BFN | C | 6395617 |
CENTURY CONSTRUCTION & SONS LTD. | BFT | C | 11/12/2019 | Open hole received - 1500 psf - Drain around habitable space - Drain designs on file - 5% grade | ASHLEYB | ASHLEYB | | BFT | C | 6395616 |
CENTURY CONSTRUCTION & SONS LTD. | BIN | C | 11/08/2019 | Received open hole | ASHLEYB | ASHLEYB | | BIN | C | 6393011 |
CENTURY CONSTRUCTION & SONS LTD. | BFR | R | 11/04/2019 | Provide open hole to complete BFT and BFN prior to any further field inspections - Reviewed with contractor on site / Need electrical permit and inspections / | JUSTINL | JUSTINL | | BFR | R | 6387955 |
CENTURY CONSTRUCTION & SONS LTD. | BFR | R | 10/03/2019 | complete BFT -- complete other rough inspections -- missing 3rd 2 2x12 header above door 2nd floor -- missing lags on deck ledger | SCOTTS | SCOTTS | | BFR | R | 6357057 |
CENTURY CONSTRUCTION & SONS LTD. | BTR | C | 10/03/2019 | | SCOTTS | SCOTTS | | BTR | C | 6357056 |
CENTURY CONSTRUCTION & SONS LTD. | BFN | P | 08/27/2019 | Foundation reinforcement with UFER observation on file - Foundation design already on file - Need open ex. observation to complete BFT inspection. | CHUCK | CHUCK | | BFN | P | 6314855 |
CENTURY CONSTRUCTION & SONS LTD. | BFT | P | 08/27/2019 | Footing observation on file - need open ex. observation to complete BFT. | CHUCK | CHUCK | | BFT | P | 6314853 |
CENTURY CONSTRUCTION & SONS LTD. | BFI | C | 08/26/2019 | R10 installed / | TIMOTHYS | TIMOTHYS | | BFI | C | 6314769 |
CENTURY CONSTRUCTION & SONS LTD. | BFD | R | 08/26/2019 | Need Open Hole and Foundation Engineering -- Need Verification of Under Drain Tie In at Street / Drain is entire - Gravity outfall -- Damp proofing OK / | TIMOTHYS | TIMOTHYS | | BFD | R | 6314767 |
MDH ELECTRIC, LLC | E= | C | 02/04/2020 | | RANDY | RANDY | | E= | C | 6473560 |
MDH ELECTRIC, LLC | ER | C | 11/06/2019 | master bedroom / bathroom with family room below | TOMC | TOMC | | ER | C | 6390372 |
L & L GAS SHOP, LLC. | H= | C | 06/26/2020 | | ANDREWP | ANDREWP | | H= | C | 6618354 |
HVAC SOLUTIONS, INC. | H= | C | 02/19/2020 | CORRECTIONS MADE SEE IMAGES | ANDREWP | ANDREWP | | H= | C | 6485326 |
HVAC SOLUTIONS, INC. | H= | P | 02/18/2020 | A/C LINE SET TO COIL NEEDS TO BE FULLY COVERED WITH INSULATION (OK TO ATTACH IMAGE TO NEXT INSPECTION) NOTE/DIRECT VENT FURNACE | ANDREWP | ANDREWP | | H= | P | 6484236 |
L & L GAS SHOP, LLC. | HC | C | 11/06/2019 | ADDING 25 K TO CURRENT DEMAND. | TREVORH | TREVORH | | HC | C | 6390236 |
L & L GAS SHOP, LLC. | HI | C | 11/06/2019 | TIFF TEST OK, FOR 10 ' OF 3/4'' BLACK IRON FROM OLD FIRE PLACE LOCATION ON MAIN LEVEL TO NEW FURNACE IN BASEMENT WITH A 25 K DIFFERENCE . | TREVORH | TREVORH | | HI | C | 6390226 |
HVAC SOLUTIONS, INC. | HRR | C | 11/04/2019 | FURNACE IS DIRECT VENT, A/C LINE COIL AND LINE SET ROUGH. CONDENSATE CHASED OVER HALLWAY. NEW OUTSIDE AIR MERGED WITH EXISTING WITH INCREASE TO 7" DAMPERED. | MARK | MARK | | HRR | C | 6387849 |
HVAC SOLUTIONS, INC. | HRP | C | 11/04/2019 | 350LB TEST OK. AT FINAL, CHECK ALL CONNECTIONS. | MARK | MARK | | HRP | C | 6387848 |