LORIC HOMES & INTERIORS | B= | C | 10/21/2020 | ESR for Spray Foam and installers certificate on file / Building final complete | ADAML | ADAML | | B= | C | 6748384 |
LORIC HOMES & INTERIORS | B= | P | 10/13/2020 | Please see previous notes / Need ESR for Spray Foam Insulation and installers certificate uploaded to permit / All other final items OK | ADAML | ADAML | | B= | P | 6738686 |
LORIC HOMES & INTERIORS | B= | P | 10/07/2020 | Still need ESR for spray foam and insulation certificate / To be uploaded by contractor shortly / All other final items OK -- Schedule a new Building Final when above items are complete. | ADAML | ADAML | | B= | P | 6732861 |
LORIC HOMES & INTERIORS | BIN | P | 12/02/2019 | Need electrical complete / Need ES report for spray foam used in exterior walls / Need insulation certificate / Check attic at final | NICK | NICK | | BIN | P | 6413192 |
LORIC HOMES & INTERIORS | BFR | P | 11/13/2019 | Frame OK pending electrical complete / Reviewed smokes and CO's | NICK | NICK | | BFR | P | 6398016 |
SMITH ELECTRIC | E= | C | 08/28/2020 | All corrections made. | BRETC | BRETC | | E= | C | 6689438 |
SMITH ELECTRIC | E= | P | 08/24/2020 | Both (2) 20 amp a/c's need to have #14NM removed for 17-25a name plate / Rest - Ok | BRETC | BRETC | | E= | P | 6683825 |
SMITH ELECTRIC | E= | P | 08/20/2020 | Need AFCI protection in upstairs middel 2 beds, kitchen, living rm, tv room, main stair 2 chandeliers / Identify all three A/C's | BRETC | BRETC | | E= | P | 6680363 |
SMITH ELECTRIC | E= | P | 08/18/2020 | main level and upstairs - TR receptacles 5 up, kitchen, dining / troubleshoot power to smokes upstairs / strap furnace mc upstairs / arc shield every thing in wood wall coverings / trouble shoot chandelier top landing of stairs not working / look at top of elevator / check kitchen and main level devices / afci/gfci | BRETC | BRETC | | E= | P | 6676885 |
SMITH ELECTRIC | E= | P | 08/17/2020 | BSMT Level only / Need GFCI Protection in mech rm / Arc arrestors on all wood / Protect NM under stairs / 2 more levels need checking | BRETC | BRETC | | E= | P | 6674719 |
SMITH ELECTRIC | ER | T | 11/27/2019 | PAID (REC#1647352) too many inspections NOTE! elevator pit okay | GARYL | GARYL | | ER | T | 6411761 |
SMITH ELECTRIC | ER | P | 11/12/2019 | Basement okay, note!! elevator power not in, question's as to what is needed for power requirements | GARYL | GARYL | | ER | P | 6396604 |
SMITH ELECTRIC | ER | P | 11/05/2019 | Main level and 2nd story okay, no basement or a/c yet, NOTE! okay for trip fees on multi inspections | GARYL | GARYL | | ER | P | 6388904 |
SYSTEMS ELECTRIC, INC. | ER | R | 05/24/2019 | south of entry total rewire --- chimney closet upstairs complete rewire --- new switches and devices through out ---- check panels in basement for water damage --- replace breakers in all basement panels | CRAIGS | CRAIGS | | ER | R | 6326925 |
MINNICK ENTERPRISES INC. | H= | C | 08/13/2020 | | MATTM | MATTM | | H= | C | 6671102 |
MINNICK ENTERPRISES INC. | H= | P | 08/12/2020 | ATTACH DUCT LEAKAGE REPORT TO NEXT INSPECTION REQUEST / NOTE / FINISHED BASEMENT / HIGH/LOW GRILLS INTO MECHANICAL ROOM / 2X PRE-EXISTING OUTSIDE AIR TO FURNACE RETURN / 3X DIRECT VENT FURNACE / 3X A/C COMPLETE / | MATTM | MATTM | | H= | P | 6670597 |
MINNICK ENTERPRISES INC. | H= | P | 08/04/2020 | LOWER MECHANICAL ROOM LACKS COMBUSTION AIR , UPPER A/C NEEDS SECONDARY KILL SWITCH . NEED KITCHEN HOOD SPECS FIREPLACE BOOKS, | DAVIDH | DAVIDH | | H= | P | 6660897 |
MINNICK ENTERPRISES INC. | H= | P | 08/04/2020 | scanned duct leakage | DAVIDH | DAVIDH | | H= | P | 6659665 |
SPRINGS GAS, INC. | H= | C | 07/10/2020 | | DAVIDH | DAVIDH | | H= | C | 6633948 |
MINNICK ENTERPRISES INC. | HRR | C | 11/13/2019 | | BENH | BENH | | HRR | C | 6397065 |
SPRINGS GAS, INC. | HC | C | 11/13/2019 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 6397051 |
SPRINGS GAS, INC. | HV | C | 11/13/2019 | SEE IMAGES DURA ROCK INSTALLED | DAVIDH | DAVIDH | | HV | C | 6397050 |
SPRINGS GAS, INC. | HV | P | 11/11/2019 | NEED NON COMBUSTIBLE BOARD INSTALLED PER MANUFACTURERS INSTRUCTION PER FIGURE 33 ON BOTH MAIN LEVEL FIREPLACES, OK TO ATTACH PICTURE TO INSPECTION REQUEST NOTES: 2- MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK | BENH | BENH | | HV | P | 6394801 |
SPRINGS GAS, INC. | HV | R | 11/08/2019 | NOT READY NO CALL AHEAD GIVEN OR LOCK BOX CODE . DROVE TO HOME LOCKED TRIED TO CONTACT CONTRACTOR NO ANSWER 4TH TRIP REQUIRED. RE-INSPECTION FEE WILL APPLY NEXT TRIP IF NOT READY | DAVIDH | DAVIDH | | HV | R | 6393578 |
SPRINGS GAS, INC. | HV | P | 11/07/2019 | I DO NOT SEE THAT ANYONE HAS CLAIMED FIREPLACES IN SCOPE OF WORK | DAVIDH | DAVIDH | | HV | P | 6392156 |
SPRINGS GAS, INC. | HI | C | 11/01/2019 | 10 lb test ok note 2 fireplaces and 1 upstairs furnace REQUESTING 2 LB SYSTEM | DAVIDH | DAVIDH | | HI | C | 6386399 |
MINNICK ENTERPRISES INC. | HRR | P | 10/21/2019 | NEED SOME TO CLAIM 2 FIREPLACES THEN I CAN COMPLETE HRR BY FINAL WILL NEED DUCT LEAK REPORT FOR ATTIC SYSTEM NOTES: FINISHED BASEMENT, DIRECT VENT FURNACE X 3, OUTSIDE AIR TO RETURN X 2, A/C ROUGH COIL AND LINE SET X 2 | BENH | BENH | | HRR | P | 6375648 |
JOLLY PLUMBING & HEATING INC. | P= | C | 07/28/2020 | Mixing valve at left master lav. | SAMH | SAMH | | P= | C | 6652038 |
JOLLY PLUMBING & HEATING INC. | PE | C | 05/22/2020 | | JANE | JANE | | PE | C | 6581668 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 11/12/2019 | Changed to PTO. Added floor drain at upper level furnace. | SAMH | SAMH | | PTO | C | 6396783 |
JOLLY PLUMBING & HEATING INC. | PTO | P | 08/23/2019 | Test OK. VTR, AAV at kitchen sinks. | SAMH | SAMH | | PTO | P | 6326380 |