GOEBEL CONSTRUCTION, INC | B= | C | 04/21/2020 | | TRENTP | TRENTP | | B= | C | 6546218 |
GOEBEL CONSTRUCTION, INC | B= | P | 04/20/2020 | Still need installers cert for blown in insulation and air leakage test / All other final items okay -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 6545305 |
GOEBEL CONSTRUCTION, INC | BSP | P | 04/17/2020 | No Burn installers cert and test report on file. Need to complete rest of final inspection items. | CHUCK | CHUCK | | BSP | P | 6543355 |
GOEBEL CONSTRUCTION, INC | B= | P | 04/16/2020 | Missing installers certs for blown in insulation, No Burn and air leakage report / Need guard at rear patio where > 30" drop within 36" of walking surface // Rest of building final OK - A/C, rear deck/cover, patio cover and finished basement. -- Schedule a new Building Final when above items are complete. | CHUCK | CHUCK | | B= | P | 6542889 |
GOEBEL CONSTRUCTION, INC | BLA | C | 01/21/2020 | | TIMOTHYS | TIMOTHYS | | BLA | C | 6459428 |
GOEBEL CONSTRUCTION, INC | BIN | C | 01/16/2020 | BIN OK - Need blown in insulation installers cert by final inspection. | CHUCK | CHUCK | | BIN | C | 6454963 |
GOEBEL CONSTRUCTION, INC | BIN | P | 01/15/2020 | Missing top plate gasket at master closet exterior walls - Provide installers certificate for blown insulation | TIMOTHYS | TIMOTHYS | | BIN | P | 6454353 |
GOEBEL CONSTRUCTION, INC | BFR | C | 01/13/2020 | | TIMOTHYS | TIMOTHYS | | BFR | C | 6451754 |
GOEBEL CONSTRUCTION, INC | BFD | C | 01/13/2020 | Drain daylights | TIMOTHYS | TIMOTHYS | | BFD | C | 6451752 |
GOEBEL CONSTRUCTION, INC | BFR | R | 01/09/2020 | Fireblocking incomplete - missing interior drop ceilings; cardboard and netting still at front door; missing at top plate for dryer vent and adjacent plumbing vent; Batt insulation does not fill entire stud cavity; foam does not completely seal penetrations - multiple locations; incomplete at fireplace chase - Will need entire re-inspection // Exterior shear OK. | CHUCK | CHUCK | | BFR | R | 6447968 |
GOEBEL CONSTRUCTION, INC | BFR | T | 01/06/2020 | PAID (REC#1654031) Will need entire fire blocking inspection - Insulators installing netting over stud cavities - unable to see all fire blocking / Drop ceilings not fire blocked yet - using cardboard and loose fill insulation - does not constitute fire blocking unless product testing for the use and method of insulation provided / Shear 5 in garage not complete / Missing edge nailing at exterior shear 3 walls - will need entire exterior shear re-inspection. | CHUCK | CHUCK | | BFR | T | 6443975 |
GOEBEL CONSTRUCTION, INC | BFR | P | 01/03/2020 | Missing draftstop throughout - Complete fireblock at main level fireplace at 10' - Complete fireblock at basement fireplace - Shear 5 garage sidewall not installed - Shear 3 rear of garage not installed - Exterior shear not inspected at this time - Received letter for framing changes where 12"oc walls were framed 16" oc and doubled - Received letter for basement window header change | TIMOTHYS | TIMOTHYS | | BFR | P | 6443110 |
GOEBEL CONSTRUCTION, INC | BSP | P | 12/23/2019 | Rear deck frame ok | TIMOTHYS | TIMOTHYS | | BSP | P | 6435706 |
GOEBEL CONSTRUCTION, INC | BSP | P | 12/09/2019 | garage narrow wall with hold down straps okay | BOBF | BOBF | | BSP | P | 6421618 |
GOEBEL CONSTRUCTION, INC | BSP | P | 12/09/2019 | front and rear porch with posts okay | BOBF | BOBF | | BSP | P | 6421616 |
GOEBEL CONSTRUCTION, INC | BFI | C | 10/28/2019 | R10 installed / | TIMOTHYS | TIMOTHYS | | BFI | C | 6381706 |
GOEBEL CONSTRUCTION, INC | BFD | P | 10/28/2019 | Drain is usable to street -- Damp proofing OK / Pending verification of connection to underdrain via photo or reinspection / | TIMOTHYS | TIMOTHYS | | BFD | P | 6381702 |
GOEBEL CONSTRUCTION, INC | BFN | C | 10/28/2019 | All papetrwork on file | TIMOTHYS | TIMOTHYS | | BFN | C | 6381701 |
GOEBEL CONSTRUCTION, INC | BFT | C | 10/28/2019 | Received Open hole, Soils report, Foundation design, Engineers observation letter for footing and foundation - Eufer noted - #3000 Bearing capacity verified - Drain to be installed usable | TIMOTHYS | TIMOTHYS | | BFT | C | 6381698 |
GOEBEL CONSTRUCTION, INC | BFT | P | 10/02/2019 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 6355058 |
GOEBEL CONSTRUCTION, INC | BFN | P | 10/02/2019 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 6355057 |
A N' M ELECTRIC | E= | C | 04/02/2020 | E= OK ----- JETTA TUB BONDING OK --- 30 AMP A/C ------ | GREGM | GREGM | | E= | C | 6530325 |
A N' M ELECTRIC | E= | R | 03/18/2020 | metal flex not grounded in island, a/,c hot tub and spa tub prewire | BRET | BRET | | E= | R | 6514184 |
A N' M ELECTRIC | EP | C | 01/02/2020 | sub-panel | TOMC | TOMC | | EP | C | 6441343 |
A N' M ELECTRIC | ES | C | 01/02/2020 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 6441335 |
A N' M ELECTRIC | ER | C | 01/02/2020 | 1 - 1/0 ser , 2 - #8 , 5 - #10 , irreversible ufer , 3 - 20 amp mcc , no central vac , finished basement , sub-panel in lower mech room , | TOMC | TOMC | | ER | C | 6441331 |
A N' M ELECTRIC | EUG | C | 12/13/2019 | 2 - 250 urd | TOMC | TOMC | | EUG | C | 6427900 |
CUSTOM CLIMATE CONTROL | H= | C | 04/02/2020 | WHOLE HOUSE VENTILATION BEING ACHIEVED WITH EXHAUST FAN LOCATED IN LAUNDRY ROOM / WHOLE HOUSE VENTILATION SWITCH LOCATED IN LAUNDRY ROOM /
NOTE/FINISHED BASEMENT / HIGH/LOW GRILLS INTO MECHANICAL ROOM / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN /2X DIRECT VENT FURNACE / A/C COMPLETE / | ANDREWP | ANDREWP | | H= | C | 6529508 |
DAVIS GAS SHOP INC | HC | C | 01/02/2020 | RELEASE METER | ANDREWP | ANDREWP | | HC | C | 6441254 |
DAVIS GAS SHOP INC | HI | C | 01/02/2020 | BY FINAL WILL NEED TO SEE REGULATORS IN PLACE AND WILL NEED 2 POUND APPROVAL LETTER FROM BLACK HILLS ,
10 LB TEST OK , 1 INCH MAIN , 2 FURNACES , 1 WATER HEATER , 1 BBQ , 1 RANGE , 2 FIRE PLACES | ANDREWP | ANDREWP | | HI | C | 6441247 |
CUSTOM CLIMATE CONTROL | HRR | C | 01/02/2020 | WHOLE HOUSE VENTILATION IS BEING ACHIEVED BY USING EXHAUST FAN IN LAUNDRY ROOM , BY FINAL VERIFY LOCATION OF DISCONNECT SWITCH
NOTES: FINISHED BASEMENT , 2X DIRECT VENT FURNACE , 1X OUTSIDE AIR WITH DAMPER , 1X A/C ROUGH COIL AND LINE SET | ANDREWP | ANDREWP | | HRR | C | 6441244 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 12/13/2019 | Fireplace and vent okay. | MARK | MARK | | HV | C | 6427607 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 04/01/2020 | Note: potable water test received, master whirlpool tub access through master closet, RP in mech room | MALYNDA | MALYNDA | | P= | C | 6527867 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 12/20/2019 | Note: Check all water connections at final, finished basement with 2 full baths, aav at single basement lav and laundry sink. AAV's at both kitchen sinks, RP in mech room. Running p-trap for garage sink is in basement, tempering at right master lav, left master lav is cwv. | MALYNDA | MALYNDA | | PTO | C | 6434306 |
HOMEOWNER | PWO | C | 12/13/2019 | Need Certificate of Potable water by final. | SAMH | SAMH | | PWO | C | 6427391 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 11/05/2019 | Water line to stub in through foundation wall. | SAMH | SAMH | | PB | C | 6388836 |