HOMEOWNER | B= | C | 05/06/2020 | All other required Final inspections are complete. (This is a computer generated result) | TRENTP | TRENTP | | B= | C | 6562388 |
HOMEOWNER | B= | P | 05/06/2020 | Items corrected / Complete pending other final inspections. Additional Inspections Required (computer generated): HOMEOWNER Plumbing Final Inspection is not Completed yet. | TRENTP | TRENTP | | B= | P | 6562212 |
HOMEOWNER | B= | R | 05/05/2020 | Handrails removed from stairs / Need code compliant handrails installed / Still need to complete P=. Additional Inspections Required (computer generated): HOMEOWNER Plumbing Final Inspection is not Completed yet. | TRENTP | TRENTP | | B= | R | 6561034 |
HOMEOWNER | BFR | P | 03/23/2020 | Frame ok pending complete roughs / Reviewed Smoke and CO requirements / Reviewed egress requirements | CHAD | CHAD | | BFR | P | 6518876 |
HOMEOWNER | E= | C | 04/30/2020 | E= OK ----- WET BAR NOT INSTALLED AT THIS TIME ---- | GREGM | GREGM | | E= | C | 6557335 |
HOMEOWNER | ER | C | 03/26/2020 | Discussed AFCI/GFCI/TR requirements with owner. / Finished Basement / sub-panel in mech room | TOMC | TOMC | | ER | C | 6522581 |
HOMEOWNER | ER | R | 03/23/2020 | add outlet to 3' wall in rec room going into hall, need dedicated circuit for ejector pit, replace #14 to 20 amp lighting circuits with #12, all j-boxes in ceiling need to be accessible, remove hall and mech outlet from bath circuit, make up all can lights, I talked to homeowner about tr/afci | MATTHEW | MATTHEW | | ER | R | 6518052 |
HOMEOWNER | H= | C | 04/28/2020 | NOTE / NO OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT FURNACE / DIRECT VENT WATER HEATER / A/C ROUGH LINESET / | MATTM | MATTM | | H= | C | 6554291 |
ABOVE WATER PLUMBING & HEATING, LLC | H= | C | 04/02/2020 | Gas final ok. Labeled and regulator at the house. | MARK | MARK | | H= | C | 6530117 |
HOMEOWNER | HRR | C | 03/25/2020 | | MATTM | MATTM | | HRR | C | 6521643 |
ABOVE WATER PLUMBING & HEATING, LLC | H= | P | 03/25/2020 | NEED MEDIUM PRESSER LETTER FROM BLACK HILLS/ WILL INSPECT REGULATOR AT FINAL/ | CHADP | CHADP | | H= | P | 6520870 |
ABOVE WATER PLUMBING & HEATING, LLC | HC | C | 03/25/2020 | RELEASE METER /OK TO RELEASE MEDIUM PRESSER METER/ | CHADP | CHADP | | HC | C | 6520862 |
ABOVE WATER PLUMBING & HEATING, LLC | HO | C | 03/25/2020 | BY FINAL WILL NEED MEDIUM PRESSER LETTER FROM BLACK HILLS AND NEED TO INSPECT REGULATOR/ 10 LB TEST OK ON EXISTING UNDERGROUND GAS LINE FROM METER AT ROAD TO RISER AT HOUSE / OK TO RELEASE 2LB METER/ | CHADP | CHADP | | HO | C | 6520854 |
ABOVE WATER PLUMBING & HEATING, LLC | HI | C | 03/25/2020 | NEED MEDIUM PRESSER LETTER /10 LB TEST OK / 1 INCH MAIN / ADDED TWO STUBS FOR FUTURE FURNACE AND A FUTURE WATER HEATER/ | CHADP | CHADP | | HI | C | 6520782 |
HOMEOWNER | HRR | P | 03/23/2020 | GAS CONTRACTOR NEEDS TO ATTACH TO PERMIT / LOWER BOTH SUPPLY TO FRAME / PATCH SUPPLY ON MAIN TRUNK OR ALSO LOWER TO FRAME / CANNOT PULL RETURN FROM A STORAGE CLOSET / OK TO SEND PICTURES TO MATTM@PPRBD.ORG / NOTE / NO OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT FURNACE / DIRECT VENT WATER HEATER / | MATTM | MATTM | | HRR | P | 6518005 |
HOMEOWNER | P= | C | 05/06/2020 | Corrections made, aav for lav in mech room Note: Bar sink to be completed with a seperate permit | MALYNDA | MALYNDA | | P= | C | 6562387 |
HOMEOWNER | P= | P | 05/05/2020 | Lav S-trapped with step up on piping after AAV / leak at lav and cannot use accordian drain / rest ok. Note: Bar sink rough in only. | DANR | DANR | | P= | P | 6561732 |
HOMEOWNER | PTO | C | 03/20/2020 | Corrections made | MALYNDA | MALYNDA | | PTO | C | 6516576 |
HOMEOWNER | PTO | P | 03/18/2020 | Finish lav dwv (photo ok), rest ok Note: aav at lav and bar sink | MALYNDA | MALYNDA | | PTO | P | 6514653 |
HOMEOWNER | PB | C | 02/19/2020 | Note: moved tub and toilet | MALYNDA | MALYNDA | | PB | C | 6485728 |