B&C CONSTRUCTION | B= | C | 10/14/2022 | handrail on exterior not required, preexisting condition | BOBF | BOBF | | B= | C | 7550803 |
B&C CONSTRUCTION | B= | L | 05/10/2022 | Womens restroom - Missing accessible sign / Flush valve on toilet must be on open side / Horizontal grab bars must be installed 33-36" to top of bar ( Currently 38 1/4" ) / Vertical grab bar must be installed 39-41" from rear wall and from floor ( Currently 42" ) / Door hardware must be single action only ( No tight grasping, pinching or twisting ) / Mens restroom - Horizontal and vertical grab bars same as Womens / Missing accessible sign / Door hardware to be single action / Office - Door hardware to be single action / Exterior stairs off Assembly Space exit must have a hand rail on both sides | ADAML | ADAML | | B= | L | 7370158 |
B&C CONSTRUCTION | BE | L | 05/10/2022 | Renewed for $152.00 at 5/10/2022 7:39:00 AM (Receipt#1865474) | SIERRAC | SIERRAC | | BE | L | 7369444 |
B&C CONSTRUCTION | BE | L | 02/03/2021 | Renewed for $152.00 at 2/3/2021 8:33:11 AM (Receipt#1747494) | SCANNING | SCANNING | | BE | L | 6857629 |
B&C CONSTRUCTION | BFR | P | 04/02/2020 | Need mechanical permit attached / Complete MEP rough inspections / Storage room frame ok / Bathroom frame ok / Door infills ok / Discussed accessible elements | TIMOTHYS | TIMOTHYS | | BFR | P | 6530009 |
JLC ELECTRIC LLC | E= | C | 01/21/2021 | Final for JLC Electric, 2- bath rooms only / Viewing rm and Gym were done by Foster electric permit on M64247 | BRETC | BRETC | | E= | C | 6844619 |
JLC ELECTRIC LLC | EE | L | 12/01/2020 | Renewed online for 1/2 Fee at 12/1/2020 6:46:53 AM (RECEIPT #: 1733245) | WEBSITE | WEBSITE | | EE | L | 6791552 |
JLC ELECTRIC LLC | E= | R | 06/01/2020 | Need to change drawings to just show bath rooms on this permit and GC find out who did the rest of the work. | BRETC | BRETC | | E= | R | 6589048 |
JLC ELECTRIC LLC | E= | P | 05/28/2020 | Gfci receptacle behind door / Drink Fountain, gfci cannot be inside / Re Wire Water heater | BRETC | BRETC | | E= | P | 6585684 |
JLC ELECTRIC LLC | E= | R | 03/16/2020 | Need POC to show where final is located | BRETC | BRETC | | E= | R | 6511363 |
JLC ELECTRIC LLC | ER | P | 03/16/2020 | 2 bath rooms walls only | BRETC | BRETC | | ER | P | 6511357 |
JACKS OF ALL TRADES, INC. | H= | C | 05/01/2020 | 2 BATH FANS AND VENTS | JERRYF | JERRYF | | H= | C | 6558873 |
AFFORDABLE ROOTER, INC | PE | L | 03/22/2022 | Renewed online for Half Fee at Mar 22 2022 11:39AM (RECEIPT #: 1852376) | WEBSITE | WEBSITE | | PE | L | 7310035 |
AFFORDABLE ROOTER, INC | P= | C | 06/18/2021 | VAC RELIEF VALVE INSTALED, NEED TO ADD WATER HEATER TO SCOPE OF WORK, REST OK | LEE | LEE | | P= | C | 7007021 |
AFFORDABLE ROOTER, INC | PTO | L | 02/05/2021 | PTO OK | LEE | LEE | | PTO | L | 6862279 |
AFFORDABLE ROOTER, INC | P= | L | 02/05/2021 | LOCKED FOR A-STATUS -- WATER HEATER MISSING VACUUM RELIEF VALVE -- REST OK | LEE | LEE | | P= | L | 6862278 |
AFFORDABLE ROOTER, INC | PE | L | 02/03/2021 | Renewed for $50.00 at 2/3/2021 8:11:49 AM (Receipt#1747470) | SAVANNAHT | SAVANNAHT | | PE | L | 6857560 |
AFFORDABLE ROOTER, INC | PTO | P | 03/12/2020 | need mechanical and electrical permits attached, need to see mens toilet flange corrected, and over head completed | JOSEPHD | JOSEPHD | | PTO | P | 6508504 |
AFFORDABLE ROOTER, INC | PTO | P | 03/12/2020 | lav rough-in moved out of accessible toilet clearance see images, will still need to make site visit to check toilet flange off side wall, and over head plumbing | JOSEPHD | JOSEPHD | | PTO | P | 6508307 |
AFFORDABLE ROOTER, INC | PTO | P | 03/06/2020 | lav drains and water lines for lavs to close to toilet side at both toilets, mens toilet to far off side wall, still need to see over head, in wall at drinking fountain ok | JOSEPHD | JOSEPHD | | PTO | P | 6503359 |
AFFORDABLE ROOTER, INC | PB | C | 02/28/2020 | connected to 4" drain | JOSEPHD | JOSEPHD | | PB | C | 6495862 |
AFFORDABLE ROOTER, INC | PB | P | 02/26/2020 | need to verify toilet clearance off side wall needs to be 16-18 off side wall, need to verify dwv connection plans call for connecting to 4" or larger, test ok | JOSEPHD | JOSEPHD | | PB | P | 6492929 |