STONE AND STEEL CONSTRUCTION INC. | B= | C | 09/24/2020 | | TRENTP | TRENTP | | B= | C | 6718489 |
STONE AND STEEL CONSTRUCTION INC. | B= | R | 09/23/2020 | Need 5 inch by 1/2 inch brushstroke address numbers on house / Observed more than 2 risers at western service door, will need minimum 18 inch landing out side door / Crawlspace, no deck | TRENTP | TRENTP | | B= | R | 6717019 |
STONE AND STEEL CONSTRUCTION INC. | BTD | C | 07/30/2020 | | TRENTP | TRENTP | | BTD | C | 6656151 |
STONE AND STEEL CONSTRUCTION INC. | BTD | R | 07/23/2020 | Inspector still unable to verify attachment of perimeter walls to foundation, every thing is covered / Need access to inside of home / No call ahead number, no one onsite , no lock box code provided | TRENTP | TRENTP | | BTD | R | 6648002 |
STONE AND STEEL CONSTRUCTION INC. | BFN | C | 07/23/2020 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 6647096 |
STONE AND STEEL CONSTRUCTION INC. | BFT | C | 07/23/2020 | Engineer letter for footing on file / | TRENTP | TRENTP | | BFT | C | 6647080 |
STONE AND STEEL CONSTRUCTION INC. | BFT | P | 07/16/2020 | Open hole on file 2000 psf / Update to soils report on file / Update states drain is not required as long as outlined criteria is met / Still need footing and foundation observations by licensed design professional | TRENTP | TRENTP | | BFT | P | 6639014 |
STONE AND STEEL CONSTRUCTION INC. | BFN | R | 06/03/2020 | No paper work provided for footing or foundation observations / Spoke to contractor about requirements / No inspection performed | TRENTP | TRENTP | | BFN | R | 6591831 |
STONE AND STEEL CONSTRUCTION INC. | BTD | R | 04/14/2020 | Need to complete BFT, BFN, BFD inspections. Plan shows a poured stem wall at center marriage line - 2x6x16 o.c. wood framed wall with 5/8" anchors at 32" o.c. installed / Cannot verify perimeter wall attachment to poured foundation // State insignia #2019-3075 with 3076 Floor Tag / Serial #19-M34062. | CHUCK | CHUCK | | BTD | R | 6540533 |
STONE AND STEEL CONSTRUCTION INC. | BFD | R | 02/25/2020 | Complete BFT, BFN - Drain covered in snow, clear or let thaw and recall inspection - EZ-Flow drain installed, provide Soils engineer approval letter for EZ-Flow drain - Provide installation instructions for EZ-Flow drain as outlines in the drain system ESR | TIMOTHYS | TIMOTHYS | | BFD | R | 6492391 |
NASH ELECTRICAL SERVICES INC. | E= | C | 04/09/2020 | | MATTHEW | MATTHEW | | E= | C | 6536075 |
NASH ELECTRICAL SERVICES INC. | ES | C | 04/09/2020 | Residential Overhead: 200 amp 3/w: new res----- need meter set and seal | MATTHEW | MATTHEW | | ES | C | 6536066 |
NASH ELECTRICAL SERVICES INC. | EUG | C | 04/02/2020 | EUG OK ----- 4/0 ------ | GREGM | GREGM | | EUG | C | 6535842 |
BULLSEYE PLUMBING HEATING & AIR | H= | C | 09/22/2020 | NOTE: CONDITIONED CRAWL SPACE / NO OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT FURNACE / ELECTRIC WATER HEATER / NO A/C | GREGV | GREGV | | H= | C | 6714015 |
BULLSEYE PLUMBING HEATING & AIR | HC | C | 09/14/2020 | RELEASE METER | DUSTINS | DUSTINS | | HC | C | 6704694 |
BULLSEYE PLUMBING HEATING & AIR | HRR | C | 09/14/2020 | | DUSTINS | DUSTINS | | HRR | C | 6704690 |
BULLSEYE PLUMBING HEATING & AIR | HRR | P | 09/09/2020 | PROPERLY TERMINATE FURNACE VENT ON ROOF PER PAGE 17 / OPEN SUPPLY VENTS IN CRAWLSPACE AND SECURE OPEN WITH SCREW / NOTE: CONDITIONED CRAWL SPACE / ELECTRIC WATER HEATER / NO A/C | MICHAELM | MICHAELM | | HRR | P | 6700460 |
BULLSEYE PLUMBING HEATING & AIR | HI | C | 05/12/2020 | 10 LB TEST OK / 1 INCH MAIN / 1 FURNACE / 1 RANGE /ELECTRIC WATER HEATER/ | CHADP | CHADP | | HI | C | 6568967 |
BULLSEYE PLUMBING HEATING & AIR | HI | L | 05/11/2020 | UNABLE TO INSPECT UNABLE TO GET LOCK BOX TO OPEN/ 10LB TEST GOOD/ 1" MAIN/ | CHADP | CHADP | | HI | L | 6567337 |
SOCO PLUMBING | P= | C | 09/18/2020 | Corrections made, water cert received | MALYNDA | MALYNDA | | P= | C | 6711422 |
SOCO PLUMBING | P= | P | 09/18/2020 | Missing support on pvc, needed every 4' (ok to send photos of corrections) Need potable water certificate, rest ok | MALYNDA | MALYNDA | | P= | P | 6711048 |
HOMEOWNER | PWO | C | 04/17/2020 | Note: water under footer, need Potable water certificate by final | MALYNDA | MALYNDA | | PWO | C | 6543640 |
STONE AND STEEL CONSTRUCTION INC. | XBS | T | 06/02/2020 | PAID (REC#1685042): PLAN SPLICE FEE: $50 by: JAY for Construction | JAY | JAY | | XBS | T | 6589948 |