ACUFF HOMES, INC. | B= | C | 08/07/2020 | | LONNYS | LONNYS | | B= | C | 6665102 |
ACUFF HOMES, INC. | B= | R | 08/06/2020 | main level missing combo detector outside of master BR / NW basement bedrooms missing egress ladders / deck stairs missing hand rail at bottom 4 steps / finished basement - rear walkout deck with stairs - A/C in. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | LONNYS | LONNYS | | B= | R | 6663373 |
ACUFF HOMES, INC. | BSP | P | 08/05/2020 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / 3rd party energy cert on file | LONNYS | LONNYS | | BSP | P | 6661290 |
ACUFF HOMES, INC. | BIN | C | 06/22/2020 | BFR complete | TIMOTHYS | TIMOTHYS | | BIN | C | 6612916 |
ACUFF HOMES, INC. | BSP | P | 06/08/2020 | Rear deck piers ok | TIMOTHYS | TIMOTHYS | | BSP | P | 6597088 |
ACUFF HOMES, INC. | BFR | C | 05/28/2020 | Engineers acceptance letter for great room framing on file | TIMOTHYS | TIMOTHYS | | BFR | C | 6585653 |
ACUFF HOMES, INC. | BLA | C | 05/21/2020 | | TIMOTHYS | TIMOTHYS | | BLA | C | 6580063 |
ACUFF HOMES, INC. | BIN | P | 05/19/2020 | Complete BFR - Insulation ok per Rescheck | TIMOTHYS | TIMOTHYS | | BIN | P | 6576914 |
ACUFF HOMES, INC. | BFR | P | 05/19/2020 | Still need engineering for great room door - Other items corrected | TIMOTHYS | TIMOTHYS | | BFR | P | 6576907 |
ACUFF HOMES, INC. | BSP | P | 05/15/2020 | FX Lumbergaurd Installers cert, AMM, and test report on file | TIMOTHYS | TIMOTHYS | | BSP | P | 6573813 |
ACUFF HOMES, INC. | BFR | P | 05/15/2020 | Still need to complete fireblock at fireplace / Still need engineering for great room door / Still need to splice added windows in study and master bedroom into plans | TIMOTHYS | TIMOTHYS | | BFR | P | 6573624 |
ACUFF HOMES, INC. | BFD | C | 05/15/2020 | | TIMOTHYS | TIMOTHYS | | BFD | C | 6573621 |
ACUFF HOMES, INC. | BFN | C | 05/15/2020 | | TIMOTHYS | TIMOTHYS | | BFN | C | 6573620 |
ACUFF HOMES, INC. | BFT | C | 05/15/2020 | Received soils report / Received foundation design / #2400 bearing capacity verified | TIMOTHYS | TIMOTHYS | | BFT | C | 6573616 |
ACUFF HOMES, INC. | BFR | P | 05/13/2020 | Complete all required foundation inspections prior to calling frame reinspection / Need to fireblock throughout / Rear kitchen window needs (3) king studs each end / Provide engineers letter and detail for great room door framing varying from provided detail / Fireblock fireplace no higher than 10' / Clean combustibles from fireplace and fireplace chase / Master bedroom side window not on plans / Studt side window not on plans / Entry door needs (3) king studs each end / Block stud bay left of entry / Front porch (2) 2x10 beam needs (1) HTS16 each end / Deck frame ok / Deck lid and posts ok | TIMOTHYS | TIMOTHYS | | BFR | P | 6571008 |
ACUFF HOMES, INC. | BFI | C | 05/13/2020 | Received engineers observation letter for foundation insulation | TIMOTHYS | TIMOTHYS | | BFI | C | 6571005 |
ACUFF HOMES, INC. | BFD | P | 05/13/2020 | Complete BFT, BFN / Received engineers observation letter for foundation drain - Dampproofing noted | TIMOTHYS | TIMOTHYS | | BFD | P | 6571003 |
ACUFF HOMES, INC. | BFN | P | 05/13/2020 | Complete BFT | TIMOTHYS | TIMOTHYS | | BFN | P | 6571002 |
ACUFF HOMES, INC. | BFT | P | 05/13/2020 | Received engineers observation letter for footing / Received engineers observation letter for foundation / Received open hole #2400 - Drain to be installed entire / Provide soils report referenced in open hole letter / Provide foundation design with listed bearing capacity design criteria | TIMOTHYS | TIMOTHYS | | BFT | P | 6571001 |
ACUFF HOMES, INC. | BTR | C | 04/29/2020 | | MICHAELM | MICHAELM | | BTR | C | 6555694 |
ACUFF HOMES, INC. | BFD | P | 02/14/2020 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFD | P | 6482492 |
ACUFF HOMES, INC. | BFT | P | 02/14/2020 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 6482491 |
ACUFF HOMES, INC. | BFN | P | 02/14/2020 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 6482490 |
WINTERS ELECTRIC, INC. | E= | C | 08/05/2020 | Corrections made / 15 amp afci hood pic was sent to my phone | BRETC | BRETC | | E= | C | 6662728 |
WINTERS ELECTRIC, INC. | E= | R | 07/30/2020 | 2 outlets in garage need to be 18" or higher from floor/ afci on fireplace/ mech room: gfci device on ceiling, need cb or lower device/30 amp a/c,ok | JOHNN | JOHNN | | E= | R | 6656322 |
WINTERS ELECTRIC, INC. | ES | C | 05/07/2020 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | BRETC | BRETC | | ES | C | 6564158 |
WINTERS ELECTRIC, INC. | ER | C | 05/07/2020 | 200 amp 3/w / IR Grnd 6' -> P / #6al Range / 10/3cu dryer / 10/2cu a/c / No mcc, cvac, Jet tub, Yes - Floor Heat mstr / FB w/o / | BRETC | BRETC | | ER | C | 6564136 |
MINNICK ENTERPRISES INC. | H= | C | 08/05/2020 | WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN BATHROOM / WHOLE HOUSE VENTILATION SWITCH LOCATED IN BATHROOM / NOTE / FINISHED BASEMENT / HIGH/LOW GRILLS INTO MECHANICAL ROOM / NO OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT FURNACE / A/C COMPLETE / | MATTM | MATTM | | H= | C | 6662364 |
MINNICK ENTERPRISES INC. | H= | R | 08/03/2020 | FLOORS BEING FINISHED CAN DO INSPECTION FOR A COUPLE DAYS SET UP WITH BUILDER | DAVIDH | DAVIDH | | H= | R | 6658708 |
SPRINGS GAS, INC. | HC | C | 05/07/2020 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 6564459 |
SPRINGS GAS, INC. | HI | C | 05/07/2020 | 10 LB TEST OK / 1 INCH MAIN / 1 FIREPLACE / 1 FURNACE / 1 RANGE / 1 WATER HEATER / | DAVIDH | DAVIDH | | HI | C | 6564454 |
FIREPLACE WAREHOUSE | HV | C | 05/06/2020 | NOTE/ MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / | DAVIDH | DAVIDH | | HV | C | 6563270 |
MINNICK ENTERPRISES INC. | HRR | C | 04/30/2020 | WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN POWDER ROOM/A/C ROUGH, COIL AND LINE SET/FINISHED BASEMENT/NO OUTSIDE AIR TO FURNACE RETURN/DIRECT VENT FURNACE | DAVIDH | DAVIDH | | HRR | C | 6557511 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 07/30/2020 | PVB installed. | SAMH | SAMH | | P= | C | 6655490 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 05/01/2020 | Corrections made. | SAMH | SAMH | | PTO | C | 6557931 |
PACIFIC PLUMBING, INCORPORATED | PTO | P | 04/27/2020 | Need to insulate 3/4" and larger hot water lines, and recirc return per IECC prescriptive method. Note: VTR, AAV at laundry sink and basement 3pc bath lav. CWV at right basement lav, Irrigation stub. | SAMH | SAMH | | PTO | P | 6552143 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 03/06/2020 | CWV at basement sink stack. | SAMH | SAMH | | PB | C | 6503183 |
ACUFF HOMES, INC. | XBS | T | 05/19/2020 | PAID (REC#1681940): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revise windows | MICHAELA | MICHAELA | | XBS | T | 6576274 |