LEWELLEN HOME IMPROVEMENT | B= | C | 12/30/2020 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 6822555 |
LEWELLEN HOME IMPROVEMENT | B= | P | 12/22/2020 | . Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | JUSTINL | JUSTINL | | B= | P | 6816038 |
LEWELLEN HOME IMPROVEMENT | B= | P | 12/18/2020 | Missing code compliant address numbers on house, will accept photos of corrections uploaded to re inspection request / Finished basement, corner deck and rear deck w/stairs, AC -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | P | 6813786 |
LEWELLEN HOME IMPROVEMENT | B=R | R | 12/17/2020 | Roof is to be inspected with building final (B=) | TRENTP | TRENTP | | B=R | R | 6810529 |
LEWELLEN HOME IMPROVEMENT | BSP | P | 12/17/2020 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TRENTP | TRENTP | | BSP | P | 6810526 |
LEWELLEN HOME IMPROVEMENT | BIN | C | 12/08/2020 | Installers cert and evaluation report for spray foam insulation on file | TRENTP | TRENTP | | BIN | C | 6799741 |
LEWELLEN HOME IMPROVEMENT | BIN | P | 12/07/2020 | Still need installers cert and evaluation report for spray foam insulation, if a thermal barrier was used will also need installers cert and evaluation report for that / Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / Intstallers cert for blown in insulation on file | TRENTP | TRENTP | | BIN | P | 6798014 |
LEWELLEN HOME IMPROVEMENT | BIN | P | 08/24/2020 | Observed R13 batt insulation over spray foam insulation / Will need installers certificate and Evaluation report for spray foam insulation and thermal barrier used / Discussed air leakage test requirements / Discussed fire protection of floors requirements / Will inspect attic insulation at final / Will need air leakage test and fire protection of floors paper work by final | TRENTP | TRENTP | | BIN | P | 6683289 |
LEWELLEN HOME IMPROVEMENT | BFR | C | 08/24/2020 | | TRENTP | TRENTP | | BFR | C | 6683273 |
LEWELLEN HOME IMPROVEMENT | BFR | P | 08/24/2020 | Re attempt at letter upload | TRENTP | TRENTP | | BFR | P | 6682437 |
LEWELLEN HOME IMPROVEMENT | BFR | P | 08/24/2020 | Upload of engineer letter for plumbing blockout / Pending field inspection | TRENTP | TRENTP | | BFR | P | 6682423 |
LEWELLEN HOME IMPROVEMENT | BFR | P | 08/12/2020 | Still need splice for over stairs, need correction for hangers from previous inspection / Contractor states splice has been submitted, inspector unable to access electronically / Spacing of joists at plumbing block out does not match spacing on engineer letter / Still need manufactures specs for hole size/distance from bearing point at plumbing blockout / All other items okay | TRENTP | TRENTP | | BFR | P | 6670014 |
LEWELLEN HOME IMPROVEMENT | BSP | P | 08/12/2020 | Letter and detail for joist block out for plumbing on file | TRENTP | TRENTP | | BSP | P | 6669326 |
LEWELLEN HOME IMPROVEMENT | BFR | R | 08/05/2020 | Still need to address items 2,3, and 8 from previous inspection / Still need splice for trusses over stairs #14/ Still need to replace all hangers from #9 from first inspection or provide letter / Missing all point loads throughout | TRENTP | TRENTP | | BFR | R | 6662403 |
LEWELLEN HOME IMPROVEMENT | BSP | P | 08/05/2020 | Letters and paper work for following items on file: Truss repairs for TO1E and TO2E, MO5 and MO6, and H24 / Header for patio door, floor joists, front vault, web stiffener, and steel beam bearing bracket detail. / Note: Direction changes for girders and trusses still needs to be updated as a splice to plans via plan review | TRENTP | TRENTP | | BSP | P | 6661215 |
LEWELLEN HOME IMPROVEMENT | BSP | P | 08/05/2020 | Upload of steel header change on file | TRENTP | TRENTP | | BSP | P | 6661181 |
LEWELLEN HOME IMPROVEMENT | BLA | C | 08/04/2020 | | CHRISTINEH | CHRISTINEH | | BLA | C | 6660430 |
LEWELLEN HOME IMPROVEMENT | BFR | R | 07/23/2020 | Still need hangers from #9 and splice for #14 from previous inspection / Need all engineer letters addressing previous inspection corrections uploaded to permit , Items 1,8, and 12 /// Inspection for lower level - - 1) Plans call for TJI210 joists; RFPT400 present / 2) Need engineer to address plumbing head out spaced over 16 O.C. / 3) Joists at plumbing headout drilled in center of web at close proximity to bearing point, will need manufactures specs for distance of holes from bearing points / 5) Window to right of basement sliding door is to have triple 2x12, triple 2x10 present / 6) Window in hallway to right of sliding door is to have triple 7 1/4 LVL, triple 2x8 present / 7) Vault room not built to plan, steel panels are to bear on foundation on all sides; west side is bearing on L shaped steel ledger / 8) Not enough bearing at beam pockets for northern steel beam outside vault room / 9) Steel beam missing web stiffener at bearing point over other steel beam closest to vault room corner // Note: Still need to inspect trusses / UPDATE TP 7/23/20 Need to review point loads at next inspection | TRENTP | TRENTP | | BFR | R | 6647950 |
LEWELLEN HOME IMPROVEMENT | BFD | C | 07/13/2020 | | TRENTP | TRENTP | | BFD | C | 6634375 |
LEWELLEN HOME IMPROVEMENT | BFN | C | 07/13/2020 | Updated stamped open hole report on file / 4000 psf | TRENTP | TRENTP | | BFN | C | 6634373 |
LEWELLEN HOME IMPROVEMENT | BFT | C | 07/13/2020 | | TRENTP | TRENTP | | BFT | C | 6634370 |
LEWELLEN HOME IMPROVEMENT | BFT | P | 07/10/2020 | Soils report on file, Bearing capacity 3000 PSF / Still need engineer stamped copy of open hole report | TRENTP | TRENTP | | BFT | P | 6632903 |
LEWELLEN HOME IMPROVEMENT | BFR | R | 07/09/2020 | Inspection stopped after too many items / Inspection is for upper level only, Still need to inspect trusses and lower level /// 1.) Need engineering for drilled top cords of TO1E and TO2E gable ends / 2.) missing strongback bracing at TO1E, TO2E, and TO8E gables / 3.) Need MTS12 at TO2J / 4.) Missing third MTS12 at TO1G and need to finish nailing HTS16s / 5.) Missing VTCRs at all V over frame trusses / 6.) Missing all ST22 "A" straps / 7.) Need to strap both top plates in master bedroom where deck cover beam is bearing in wall / 8.) Need engineer letter for steel beam headers at sliding doors in great room / 9.) Need to strap top plates in master closet at plumbing in exterior bearing wall / Need engineering for alternative hardware used in place of HGUS28XSKL's at front office / 10.) Missing second MTS12 and finish nailing HGUS at BG3 / 11.) Missing bearing block and (4) HTS16s at bearing point for BG1 / 12.) Need to fully seat MO5 and MO6 trusses in hangers / 13.) Need to complete fireblocking and draftstopping throughout / 14.) Need splice for direction change of girders and trusses over main stairwell // UPDATE: TP 7/9/20 Need to complete BFT and BFN prior to further inspections | TRENTP | TRENTP | | BFR | R | 6632179 |
LEWELLEN HOME IMPROVEMENT | BSP | P | 07/09/2020 | Narrow braced wall okay / Still need hangers for front porch beams | TRENTP | TRENTP | | BSP | P | 6632116 |
LEWELLEN HOME IMPROVEMENT | BSP | P | 07/09/2020 | Narrow braced wall detail and changes to frame engineer letter on file | TRENTP | TRENTP | | BSP | P | 6631366 |
LEWELLEN HOME IMPROVEMENT | BFN | P | 07/09/2020 | open hole on file -- 3000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / Need soils report in order to complete BFT / UPDATE: TP 7/9/20 Open hole report on file is not stamped by engineer / Need stamped copy | TRENTP | TRENTP | | BFN | P | 6631358 |
LEWELLEN HOME IMPROVEMENT | BSP | R | 06/29/2020 | Inspection for Narrow braced walls, porch covers and deck frames / Narrow braced walls covered in Tyvek at time of inspection, Need Narrow Braced Wall detail called out on roof framing plan; Detail not present in plans / Need engineering for triple beam at front porch bearing over header of window where a hanger is called on plans / Need engineering for double LVL used as porch cover ledger southwest corner deck / Need engineering of missing hanger at double beam for southwestern deck frame, Observed 3 ledger locks in the side into rim joist / Missing hanger in other beam on same deck / Need to complete fastening at hanger for beam on northwest deck at northwest corner / Observed piers for deck landing / Need to complete BFT and BFN | TRENTP | TRENTP | | BSP | R | 6620669 |
LEWELLEN HOME IMPROVEMENT | BFI | C | 03/04/2020 | R10 installed / | TIMOTHYS | TIMOTHYS | | BFI | C | 6500447 |
LEWELLEN HOME IMPROVEMENT | BFD | R | 03/04/2020 | Need Open Hole and Foundation Engineering -- Drain daylights west / Drain is installed usable -- Damp proofing OK / | TIMOTHYS | TIMOTHYS | | BFD | R | 6500446 |
LEWELLEN HOME IMPROVEMENT | BFT | P | 03/03/2020 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 6498059 |
LEWELLEN HOME IMPROVEMENT | BFN | P | 03/03/2020 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 6498058 |
WESTERN ELECTRIC | E= | C | 12/15/2020 | | TOMC | TOMC | | E= | C | 6808832 |
WESTERN ELECTRIC | E= | R | 12/14/2020 | cannot have open lamps in master closet , receptacles in laundry have no power , lower bedroom receptacles have no power , gfi protect garage frig , adjust panel deadfront | TOMC | TOMC | | E= | R | 6806353 |
WESTERN ELECTRIC | ER | C | 06/18/2020 | 1 - #2 AL , 4 - #8 , 1 - #10 , IRREVERSIBLE UFER , NO MCC , NO CENTRAL VAC , FINISHED BASEMENT , SUB-PANEL IN BASEMENT | TOMC | TOMC | | ER | C | 6609084 |
WESTERN ELECTRIC | ES | C | 05/27/2020 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / bond metal box on outside of building | TOMC | TOMC | | ES | C | 6584530 |
WESTERN ELECTRIC | EUG | C | 05/22/2020 | pvc from pole to home | MATTHEW | MATTHEW | | EUG | C | 6581117 |
OAK VIEW INVESTMENTS, LLC | H= | C | 12/16/2020 | WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN LAUNDRY ROOM / WHOLE HOUSE VENTILATION SWITCH LOCATED IN LAUNDRY ROOM / NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE X2 / DIRECT VENT TANKLESS WATER HEATER X2 / A/C COMPLETE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN X2 / | BILLS | BILLS | | H= | C | 6809485 |
GROUNDHOG CONSTRUCTION | HC | C | 06/29/2020 | RELEASE METER | ANDREWP | ANDREWP | | HC | C | 6621246 |
GROUNDHOG CONSTRUCTION | HRR | C | 06/29/2020 | WHOLE HOUSE VENTILATION BEING ACHIEVED WITH EXHAUST FAN LOCATED IN LAUNDRY ROOM / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / | ANDREWP | ANDREWP | | HRR | C | 6621237 |
MJB PLUMBING AND HEATING, INC | HI | C | 06/25/2020 | 10 LB TEST OK | ANDREWP | ANDREWP | | HI | C | 6617486 |
GROUNDHOG CONSTRUCTION | HRR | P | 06/25/2020 | MISSING EXHAUST FAN IN LAUNDRY ROOM FOR WHOLE HOUSE VENTILATION
NOTE/ FINISHED BASEMENT/ 2 DIRECT VENT FURNACE/ 2 TANKLESS WATER HEATER/ NO OUTSIDE AIR/ A/C ROUGH COIL AND LINE SET | ANDREWP | ANDREWP | | HRR | P | 6617483 |
MJB PLUMBING AND HEATING, INC | HI | P | 06/24/2020 | LOW TEST
2 INCH MAIN / 2 FURNACES/ 2 WATER HEATER/ 1 BBQ / 3 FIRE PLACES/ 1 RANGE | ANDREWP | ANDREWP | | HI | P | 6615506 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 06/22/2020 | BOTH MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / BASEMENT FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / | ANDREWP | ANDREWP | | HV | C | 6612459 |
MJB PLUMBING AND HEATING, INC | P= | C | 12/18/2020 | Potable water certificate attached | MALYNDA | MALYNDA | | P= | C | 6812336 |
MJB PLUMBING AND HEATING, INC | P= | P | 12/17/2020 | corrections made ( see images ), still need certificate of potable water. | TAYLOR | TAYLOR | | P= | P | 6810543 |
MJB PLUMBING AND HEATING, INC | P= | P | 12/16/2020 | need air gap at auto flush and T&P drain installed at steam generator, anchor front hose bib, aav needs to be installed in the vertical position at bar sink, need certificate of potable water, rest ok, pvb installed, finished basement. | TAYLOR | TAYLOR | | P= | P | 6809696 |
MJB PLUMBING AND HEATING, INC | PWO | C | 07/01/2020 | Note: check all water connections in well pit at final, verify back flow in well pit for garage yard hydrant at final, need potable water certificate | MALYNDA | MALYNDA | | PWO | C | 6623566 |
MJB PLUMBING AND HEATING, INC | PTO | C | 06/16/2020 | Note: Finished basement (2 full baths), aav's at all basement lavs and bar sink, aav's at both master lavs, laundry sink is cwv, irrigation stub, steam shower clearance verified in master shower, check for tempering at master tub by final, check for expansion *Need steam shower install instructions at final | MALYNDA | MALYNDA | | PTO | C | 6606321 |
MJB PLUMBING AND HEATING, INC | PB | C | 03/18/2020 | Corrections made | MALYNDA | MALYNDA | | PB | C | 6514713 |
MJB PLUMBING AND HEATING, INC | PB | P | 03/17/2020 | Lacking grade throughout (all marked), rest ok | MALYNDA | MALYNDA | | PB | P | 6513358 |
LEWELLEN HOME IMPROVEMENT | XBS | T | 08/20/2020 | PAID (REC#1706378): PLAN SPLICE FEE: $50 by: DANM for Construction: Revised door header, trusses rotated on tower, floor plan clarifications | DANM | DANM | | XBS | T | 6680143 |