BOB MCGRATH CONSTRUCTION LLC | B= | C | 12/10/2021 | Crawlspace -- Rear deck, no stairs // UPDATE 12/10/21 by DRS - changed inspection from BSP to B= | DAKOTAB | DAKOTAB | | B= | C | 7205941 |
BOB MCGRATH CONSTRUCTION LLC | BIN | C | 12/10/2021 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 received -- ES report and installers cert. for sray foam insulation and for thermal barrier received | DAKOTAB | DAKOTAB | | BIN | C | 7205936 |
BOB MCGRATH CONSTRUCTION LLC | B= | T | 12/10/2021 | PAID (REC#1828882): AFTER-HOURS INSPECTION: $200 From: DANE after hours B= | DANE | DANE | | B= | T | 7205893 |
BOB MCGRATH CONSTRUCTION LLC | BLA | C | 07/19/2021 | | LONNYS | LONNYS | | BLA | C | 7040745 |
BOB MCGRATH CONSTRUCTION LLC | BFR | C | 06/29/2021 | Engineer letter for AG1 bearing block on file | TRENTP | TRENTP | | BFR | C | 7018405 |
BOB MCGRATH CONSTRUCTION LLC | BIN | P | 06/23/2021 | Need to complete BFR / Need to provide installers certificate and evaluation report for spray foam insulation / Need to provide evaluation report for thermal barrier sprayed over foam / Need air leakage test results by final | TRENTP | TRENTP | | BIN | P | 7013415 |
BOB MCGRATH CONSTRUCTION LLC | BFR | P | 06/23/2021 | Still need to correct bearing block at AG1 per previous notes / All other items corrected | TRENTP | TRENTP | | BFR | P | 7013414 |
BOB MCGRATH CONSTRUCTION LLC | BSP | P | 06/11/2021 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | TRENTP | TRENTP | | BSP | P | 6998917 |
BOB MCGRATH CONSTRUCTION LLC | BFR | P | 06/10/2021 | 1. Still need to complete items 3,5,8, and 9 from previous BFR, all other items corrected // Notes for crawlspace/basement // 2. Multiple steel post unsecured to steel beams on west side of crawl space / 3. Unsecured tube steel post at eastern side under master bedroom/great room wall in crawlspace / 4. Missing 3" steel post middle of double LVL under master bedroom/great room wall / 5. Missing ledger locks at exterior awning to basement access / 6. Incomplete fastening for hangers at triple LVL in basement mech room / 7. Over space floor joists at crawlspace/basement wall / Note: Provide Test report and installers certificate for materials used for fire protection of floor per IRC 302.13 EX #4 / Will inspect garage awning and APL6 brackets as BSP at later date / unfinished basement mech room/crawlspace, rear deck | TRENTP | TRENTP | | BFR | P | 6997774 |
BOB MCGRATH CONSTRUCTION LLC | BSP | P | 06/10/2021 | Master bedroom truss repairs on file | TRENTP | TRENTP | | BSP | P | 6997361 |
BOB MCGRATH CONSTRUCTION LLC | BFR | R | 06/09/2021 | Note: Still need to inspect crawlspace / 1. Still need to correct numbers 3,6, and 8 from previous BSP, Still missing APL6 post brackets at front porches, Rest of previous BSP items corrected / 2. Need to strap studs at buttress bearing point in master bedroom / 3. Missing steel post under steel beam / 4. Missing hangers at M1 and M2 trusses next to slide / 5. Missing VCTR clips at all over framing / 6. Missing hangers for BM7 and BM8 trusses / 7. Missing blocking for punching bag in workout room / 8. Missing LTS12s at all N trusses in workout room / 9. Bearing block at AG1 to be attached to bottom cord per plan / Note: Will need to review all fastener requirements discussed on site with super / Still need to inspect awnings when built | TRENTP | TRENTP | | BFR | R | 6996319 |
BOB MCGRATH CONSTRUCTION LLC | BSP | P | 06/09/2021 | Engineer letter for anchor bolts and hanger fasteners on file | TRENTP | TRENTP | | BSP | P | 6995497 |
BOB MCGRATH CONSTRUCTION LLC | BSP | P | 06/07/2021 | Engineered truss repair details on file | TRENTP | TRENTP | | BSP | P | 6992420 |
BOB MCGRATH CONSTRUCTION LLC | BSP | R | 06/04/2021 | Inspection comment states truss repair upload, No images received / Discussed uploading images with call ahead / Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | TRENTP | TRENTP | | BSP | R | 6990811 |
BOB MCGRATH CONSTRUCTION LLC | BSP | R | 06/02/2021 | Inspection changed for BSP / Inspection for frame of garage, upper level, and mudroom and master bedroom/bathroom only / 1. Still need to upload all requested paperwork and repairs from previous BSP and make corrections / 2. Unable to confirm anchor bolts throughout / 3. Missing all HTT4s per note 101 / 4. Need to strap all over drill/notched top plates throughout / 5. Need updated engineering for upstairs hallway window framing / 6. Incorrect fasteners used in all HUS/HGUS/IUS hardware / 7. Need updated engineering for steel framing added to observatory / 8.Missing MTCS straps at steel bearing point for AG5 / 9. Incomplete fireblocking through out / 10. Need updated engineering for master closet windows / 11. Trusses not properly seated in hangers in master bedroom / Note: Still need to inspect rest of main and lower level, Previous BSP notes not observed at this time | TRENTP | TRENTP | | BSP | R | 6988633 |
BOB MCGRATH CONSTRUCTION LLC | BFD | C | 06/02/2021 | Engineer letter for use of EZ flow drain on file | TRENTP | TRENTP | | BFD | C | 6987401 |
BOB MCGRATH CONSTRUCTION LLC | BSP | R | 06/01/2021 | Changed to BSP / Observed updated plans onsite -Need attached submitted to PPRBD plan review / TRUSSES- Broken web D3 / Broken bottom cord A1 / Rest of truss bracing ok - Still need to inspect truss clips / FRONTPORCH LID - Missing APL6 post brackets / Missing Bolts at HTT4 / Rest of lid ok / REAR PATIO LID - Missing straps at post to beam connection / Missing HTT4 and bolts at posts / Need updated detail front metal awning | CHAD | CHAD | | BSP | R | 6987210 |
BOB MCGRATH CONSTRUCTION LLC | BIN | P | 06/01/2021 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | SIERRAC | SIERRAC | | BIN | P | 6986006 |
BOB MCGRATH CONSTRUCTION LLC | BFN | C | 05/25/2021 | Soils report on file | TRENTP | TRENTP | | BFN | C | 6979547 |
BOB MCGRATH CONSTRUCTION LLC | BFT | C | 05/25/2021 | Soils report on file | TRENTP | TRENTP | | BFT | C | 6979545 |
BOB MCGRATH CONSTRUCTION LLC | BFN | P | 05/25/2021 | Need soils report, open hole already on file | TRENTP | TRENTP | | BFN | P | 6979508 |
BOB MCGRATH CONSTRUCTION LLC | BFT | P | 05/25/2021 | Still need soils report to complete BFT / open hole on file -- 2000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | TRENTP | TRENTP | | BFT | P | 6979504 |
BOB MCGRATH CONSTRUCTION LLC | BFD | R | 05/21/2021 | Still need to complete BFT and BFN as well as provide engineer confirmation for the use of EZ flow drain | TRENTP | TRENTP | | BFD | R | 6976537 |
BOB MCGRATH CONSTRUCTION LLC | BFN | P | 05/21/2021 | Need to complete BFT to verify bearing capacity of foundation design / Interior pad letter on file | TRENTP | TRENTP | | BFN | P | 6976534 |
BOB MCGRATH CONSTRUCTION LLC | BFT | P | 05/21/2021 | Still need to provide soils report and open hole to confirm bearing capacity of design / Footing and foundation observation already on file | TRENTP | TRENTP | | BFT | P | 6976529 |
BOB MCGRATH CONSTRUCTION LLC | BFI | C | 11/02/2020 | R10 @ 24 inches / Note: Need to complete BFT, BFN, and BFD | TRENTP | TRENTP | | BFI | C | 6761042 |
BOB MCGRATH CONSTRUCTION LLC | BFI | R | 10/30/2020 | Foundation insulation not installed | CHAD | CHAD | | BFI | R | 6760222 |
BOB MCGRATH CONSTRUCTION LLC | BFD | P | 10/30/2020 | Complete BFT BFN inspections / EZ flow installed - Drain daylights back corners / Damp proofing observed / | CHAD | CHAD | | BFD | P | 6760221 |
BOB MCGRATH CONSTRUCTION LLC | BFI | P | 10/30/2020 | Footing and foundation observations on file / Pending field inspection for foundation insulation | TRENTP | TRENTP | | BFI | P | 6759240 |
BOB MCGRATH CONSTRUCTION LLC | BFN | P | 10/30/2020 | Foundation design and observation on file / Need to complete BFT | TRENTP | TRENTP | | BFN | P | 6759234 |
BOB MCGRATH CONSTRUCTION LLC | BFD | P | 10/30/2020 | Installation instructions for EZ flow drain on file / Pending field inspection / Note: Will need engineers confirmation for use of EZ flow drain | TRENTP | TRENTP | | BFD | P | 6759214 |
BOB MCGRATH CONSTRUCTION LLC | BFT | P | 10/30/2020 | Need soils and open hole reports / Footing and foundation observations, Observation states 72 inch concrete pad was not inspected at this time, will need to provide observation / Foundation design on file | TRENTP | TRENTP | | BFT | P | 6759208 |
POSITIVE ELECTRIC, LLC | E= | C | 12/10/2021 | A/C units to be under separate permit | DEAN | DEAN | | E= | C | 7205739 |
POSITIVE ELECTRIC, LLC | E= | P | 12/10/2021 | a/cs are set but not wired---------electrically safe to move in | RANDY | RANDY | | E= | P | 7205535 |
POSITIVE ELECTRIC, LLC | E= | R | 12/08/2021 | Need to protect wire in master bathroom cabinets. --- Need to check both island receptacles (Not ready). --- Need to check basement. --- Wire 4x A/C units --- Need panel schedules completed. --- All out side can lights need to be trimmed. | AARONR | AARONR | | E= | R | 7201738 |
POSITIVE ELECTRIC, LLC | ES | C | 10/13/2021 | Residential Underground: 3 -200 amp services | BRET | BRET | | ES | C | 7140584 |
POSITIVE ELECTRIC, LLC | EUG | C | 10/08/2021 | 3 rd run of 4/0-4/0-2/0 | BRET | BRET | | EUG | C | 7135286 |
MESA ELECTRIC, LLC. | ER | C | 05/17/2021 | island all millwork | BRET | BRET | | ER | C | 6970960 |
MESA ELECTRIC, LLC. | EP | C | 05/14/2021 | 6 sub panels ok | BRET | BRET | | EP | C | 6969264 |
MESA ELECTRIC, LLC. | ER | P | 05/14/2021 | add receptacles to area at stairs, need framing done for island, install lights in patio cover rest ok | BRET | BRET | | ER | P | 6969263 |
MESA ELECTRIC, LLC. | ER | R | 05/13/2021 | need gate code or better directions | TOMC | TOMC | | ER | R | 6967906 |
MESA ELECTRIC, LLC. | EUG | C | 11/06/2020 | EUG OK ---2- 250 URD ----- | GREGM | GREGM | | EUG | C | 6768614 |
MESA ELECTRIC, LLC. | EUG | C | 11/06/2020 | EUG OK ------ 250 URD X 2 ----- | GREGM | GREGM | | EUG | C | 6768207 |
BESTWAY MECHANICAL LLC | H= | C | 12/10/2021 | CONDITIONED CRAWLSPACE WITH 2 SUPPLIES AND RETURN | JHORSMAN | JHORSMAN | | H= | C | 7205938 |
BOB MCGRATH CONSTRUCTION LLC | H= | T | 12/10/2021 | PAID (REC#1828879): AFTER-HOURS INSPECTION: $200 From: JON After hours heat final inspection | JON | JON | | H= | T | 7205875 |
BESTWAY MECHANICAL LLC | H= | P | 12/10/2021 | IECC/IRC VENTILATION VERIFICATION APPROVED BY PLAN REVIEW/ PROVIDE FIREPLACE INSTALLATION INSTRUCTION TO VERIFY MANTEL CLEARANCES/ PROVIDE CRAWLSPACE VENTILATION/ | JHORSMAN | JHORSMAN | | H= | P | 7205205 |
BESTWAY MECHANICAL LLC | H= | R | 12/10/2021 | IECC/IRC VENTILATION VERIFICATION IMAGE CANNOT BE TAKEN AS AN IMAGE. MUST BE SUBMITTED TO PLAN REVIEW/ PER CONTRACTOR SUPPLY AND RETURN IN CRAWLSPACE ARE FOR FUTURE WINE CHILLER, HOW IS THE CRAWLSPACE BEING CONDITIONED? | JHORSMAN | JHORSMAN | | H= | R | 7204418 |
THE FIREPLACE DOCTOR, INC. | H= | P | 12/09/2021 | ON A 101 NEW BUILD THE MECHANICAL CONTRACTOR IS THE ONLY HEAT FINAL. THE FIREPLACE WILL BE LOOKED AT FOR MANTEL CLEARANCES WHEN THE MECHANICAL CONTRACTOR CALLS IN FOR A HEAT FINAL INSPECTION. | JHORSMAN | JHORSMAN | | H= | P | 7202986 |
BESTWAY MECHANICAL LLC | H= | P | 12/08/2021 | PROVIDE PLAN REVIEW AN UPDATED IECC/IRC VENTILATION VERIFICATION FORM INDICATING WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH HVRs AND THE CFM'S OF ALL EXHAUST FANS/ PROVIDE FIREPLACE INSTALLATION INSTRUCTIONS/ INSTALL SUPPLY AND RETURN GRILLS IN CRAWLSPACE, OK TO ATTACH PICTURES OF GRILLS/ COMPLETE A/C INSTALLATION, ENSURE LINESET TERMINATES AT COIL CABINET AND IS SEALED/ LABEL WHOLE HOUSE VENTILATION SWITCHES/ Whole house ventilation being achieved with dampered outside air duct to hrv. / Whole house ventilation switch located in every bathroom/ NOTE / CONDITIONED CRAWL SPACE / OUTSIDE AIR WITH DAMPER TO HRV SYSTEM / DIRECT VENT BOILER X2/ ELECTRIC AIR HANDLER X4/ HRV X3/ A/C COMPLETE X4/ | JHORSMAN | JHORSMAN | | H= | P | 7201894 |
BESTWAY MECHANICAL LLC | HWP | C | 07/01/2021 | 50 LB TEST OK FOR LAST RADIANT ZONE IN KITCHEN | TREVORH | TREVORH | | HWP | C | 7022351 |
BESTWAY MECHANICAL LLC | HWP | P | 07/01/2021 | pictures of completed radiant install ok See images. Still need to verify one 50 lb test for kitchen zone. the rest ok. | TREVORH | TREVORH | | HWP | P | 7021765 |
BESTWAY MECHANICAL LLC | HWP | P | 06/30/2021 | 50 LB TEST OK FOR 15 ZONES OK / NEED TO SEE 50 LB TEST OF ZONE SERVING KITCHEN GAUGE HAS BEEN DAMAGED AND NOT READING ACCURATELY , WILL NEED TO SEE PICTURES OF INSTALL AS RADIANT HAS BEEN COVERED PRIOR TO PASSING INSPECTION. | TREVORH | TREVORH | | HWP | P | 7021285 |
BESTWAY MECHANICAL LLC | HWP | P | 06/29/2021 | COULD NOT GAIN ACCESS TO THE PRIVATE DRIVE , POLICE HAVE HWY 83 BLOCKED AT OLD NORTH GATE TO NORTH GATE | TREVORH | TREVORH | | HWP | P | 7019556 |
BESTWAY MECHANICAL LLC | HWP | P | 06/25/2021 | UNABLE TO FIND WHERE UPPER LEVEL IN FLOOR RADIANT HEAT IS TIED IN FOR TEST OR TEST GAUGES FOR UPPER LEVEL. LOW TEST ON THE TWO LOOPS FOR GUEST ROOM/GUEST BATH AND BUNK ROOM/BATH 3. ONE AT 0 LB AND OTHER AT 30 LB. EIGHT 50 LB TEST OK ON IN FLOOR RADIANT HEAT FOR REST OF MAIN LEVEL. | DUSTINS | DUSTINS | | HWP | P | 7015673 |
BESTWAY MECHANICAL LLC | HO+ | C | 06/14/2021 | 10 LB TEST OK FOR 125' OF 1'' POLY WITH TRACER WIRE FROM EXTERIOR MAIN TO NEW 85 K OUTDOOR BBQ , 10 LB TEST OK FOR 54' OF 3/4'' POLY WITH TRACER WIRE FROM RISER AT BBQ TO FUTURE 65K OUTDOOR FIRE PLACE . 10 LB TEST OK FOR 48' OF 3/4'' POLY WITH TRACER WIRE FROM EXTERIOR MAIN TO NEW 275 K GENERATOR. AT FINAL WILL NEED TO VERIFY ALL APPLIANCES HAVE BEEN CONVERTED TO LP, OK TO BURY LINES. | TREVORH | TREVORH | | HO+ | C | 7001232 |
BESTWAY MECHANICAL LLC | HRR | C | 06/02/2021 | HOME IS GETTING SPRAY FOAM INSULATION , AIR HANDLERS ARE COOLING ONLY, AT FINAL WILL NEED TO VERIFY ALL FUEL BURNING APPLIANCES HAVE BEEN CONVERTED TO PROPANE, WILL NEED TO SEE FINAL CONNECTIONS TO HRV IN ATTIC ,WILL ALSO NEED TO VERIFY ALL PLATFORMS AND WALKWAYS TO ATTIC EQUIPMENT , AT FINAL WILL NEED TO SEE PLAN SPLICE FOR DUCT CHANGES, NEED THE IECC VENTILATION VERIFICATION UPDATED LISTING THE WHOLE HOUSE VENTILATION INTENDED USAGE OF THE HRV AND LISTING ALL CFM'S INCLUDING KITCHEN HOOD, WILL NEED TO VERIFY CRAWLSPACE CONDITIONING . WHOLE HOUSE VENTILATION IS BEING ACHIEVED BY THE OUTSIDE AIR THROUGH THE HRV, VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT BOILER X 2 / 3 HRV /4 ELECTRIC AIR HANDLER / A/C ROUGH, COIL AND LINESET X 4 / | TREVORH | TREVORH | | HRR | C | 6987274 |
THE FIREPLACE DOCTOR, INC. | HV | C | 06/01/2021 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / | TREVORH | TREVORH | | HV | C | 6986657 |
BESTWAY MECHANICAL LLC | HRP | P | 05/27/2021 | NEED TO SEE PRESSURE TEST FOR THE BRAZED LINE SET, NEED TO SEE SUCTION LINE INSULATION REPAIR ABOVE CEILING IN GARAGE. | TREVORH | TREVORH | | HRP | P | 6984284 |
BESTWAY MECHANICAL LLC | HI | C | 05/27/2021 | (LP SYSTEM) 10 LB TEST OK / 1 1/4 INCH MAIN / 1 BBQ / 2 BOILER / 1 FIREPLACE / 1 FUTURE FIRE PIT / 1 GENERATOR / | TREVORH | TREVORH | | HI | C | 6984234 |
BESTWAY MECHANICAL LLC | HRR | P | 05/27/2021 | NEED FIRE PLACE CONTRACTOR ATTACHED TO PERMIT , NEED TO CONSULT BUILDING ON PLATFORMS FOR THE HRV'S HOME IS GETTING SPRAY FOAM INSULATION , AIR HANDLERS ARE COOLING ONLY, AT FINAL WILL NEED TO VERIFY ALL FUEL BURNING APPLIANCES HAVE BEEN CONVERTED TO PROPANE, WILL NEED TO SEE FINAL CONNECTIONS TO HRV IN ATTIC ,WILL ALSO NEED TO VERIFY ALL PLATFORMS AND WALKWAYS TO ATTIC EQUIPMENT , AT FINAL WILL NEED TO SEE PLAN SPLICE FOR DUCT CHANGES, NEED THE IECC VENTILATION VERIFICATION UPDATED LISTING THE WHOLE HOUSE VENTILATION INTENDED USAGE OF THE HRV AND LISTING ALL CFM'S INCLUDING KITCHEN HOOD, WILL NEED TO VERIFY CRAWLSPACE CONDITIONING . WHOLE HOUSE VENTILATION IS BEING ACHIEVED BY THE OUTSIDE AIR THROUGH THE HRV, VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT BOILER X 2 / 3 HRV /4 ELECTRIC AIR HANDLER / A/C ROUGH, COIL AND LINESET X 4 / | TREVORH | TREVORH | | HRR | P | 6984224 |
BESTWAY MECHANICAL LLC | HRR | R | 05/24/2021 | NOT READY / MULTIPLE INCOMPLETE DUCT RUNS FOR HRV SYSTEM ON WEST SIDE OF HOUSE / PROVIDE ACCESS TO CRAWLSPACE FOR FULL INSPECTION OF DUCT SYSTEM- ALL DUCT-WORK THROUGHOUT CRAWLSPACE MUST BE SUPPORTED ABOVE GRADE TO CODE / MISSING NAIL PROTECTION FOR LINE-SET ON WALL OPPOSITE OF LOWER LEVEL LAUNDRY ROOM / INSTALL DRYER DUCT FOR UPPER LEVEL LAUNDRY ROOM / CONTRACTOR TO VERIFY SPRAY FOAM INSULATION INSTALLATION IN ATTIC - VERIFICATION TO ENSURE DUCT LEAKAGE REPORT REQUIREMENTS / IECC VENTILATION VERIFICATION FORM HAS RANGE EXHAUST MARKED AS PROVISION FOR WHOLE HOUSE VENTILATION RUNNING CONSTANT? STOPPED INSPECTION, CONTRACTOR TO WALK JOB PRIOR TO CALLING FOR INSPECTION - RE-INSPECT ALL / | WHITNEYH | WHITNEYH | | HRR | R | 6979274 |
GLASER ENERGY GROUP INC. | HO | C | 12/10/2020 | 10 LB TEST OK / | BILLS | BILLS | | HO | C | 6803413 |
GLASER ENERGY GROUP INC. | HO | P | 12/08/2020 | LOW TEST 5LBS NOTE / 40' OF 1/2" POLY PIPE WITH TRACER WIRE FROM TANK TO REGULATOR LOCATION / | BILLS | BILLS | | HO | P | 6799888 |
BESTWAY PLUMBING, INC | HWP | P | 11/13/2020 | 50 LB TEST OK ON IN FLOOR RADIANT HEAT FOR GARAGE. OK TO COVER. | DUSTINS | DUSTINS | | HWP | P | 6775566 |
BESTWAY PLUMBING, INC | HWP | P | 11/12/2020 | NO TEST. CONTRACTOR STILL INSTALLING UPON ARRIVAL. WAITED 15 MINUTES FOR PIPING TO BE PUT ON TEST, HAS LEAK. STOPPED INSPECTION. IN FLOOR RADIANT HEAT IN GARAGE. | DUSTINS | DUSTINS | | HWP | P | 6774348 |
BESTWAY MECHANICAL LLC | P= | C | 12/10/2021 | master bathroom tub and shower not finishing at this time, will need a permit when completing note: potable water certification received, no irrigation | JOSEPHD | JOSEPHD | | P= | C | 7205270 |
BESTWAY MECHANICAL LLC | P= | P | 12/08/2021 | bathroom #6 ok, still need to see rest of house | JOSEPHD | JOSEPHD | | P= | P | 7201552 |
BESTWAY MECHANICAL LLC | PTO | C | 04/30/2021 | note: no irrigation, need potable water certification by final, check water heaters and utility room piping by final, test caps on roof vents, check for tempering at master tub at final, verify freeze protection in attic for water lines at final (attic will be foamed at roof), aav @ hall wet bar, both master lavs, in mech at floor drain, ejector vented thru roof, kitchen sink vented, vtr 6 | JOSEPHD | JOSEPHD | | PTO | C | 6953678 |
BOB MCGRATH CONSTRUCTION LLC | PWO | C | 12/09/2020 | TWO WELLS, ONE TO A CISTERN THEN LOOPED INTO OTHER LINE THEN BYPASSES OLD CISTERN AND FEEDS EXISTING / NEW | LEE | LEE | | PWO | C | 6802138 |
BESTWAY PLUMBING, INC | PB | C | 11/11/2020 | Note: floor drain with vent in south part of house | MALYNDA | MALYNDA | | PB | C | 6772941 |
BOB MCGRATH CONSTRUCTION LLC | XMS | P | 12/10/2021 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical: Revised equipment cert and HRV | DALEH | DALEH | | XMS | P | 7205168 |
BOB MCGRATH CONSTRUCTION LLC | XBS | T | 06/08/2021 | PAID (REC#1779280): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Structural revisions | MICHAELA | MICHAELA | | XBS | T | 6993806 |
BOB MCGRATH CONSTRUCTION LLC | XBS | T | 10/14/2020 | PAID (REC#1725637): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revise structural page | MICHAELA | MICHAELA | | XBS | T | 6740254 |