CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 06/05/2024 | ACCIDENT REPORT RECORDED - SEE IMAGES | DUSTINS | DUSTINS | | HE16 | C | 8107969 |
CTY OF C/S - MUNICIPAL AIRPORT | H07 | C | 05/15/2024 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS W/ SCHINDLER -- MINIMUM BRAKE TORQUE 81 FT/LBS, ACTUAL 115 FT/LBS -- / UPPER PIT GFCI NOT WORKING. CLUNKING NOISE AT TOP END WHILE IN NORMAL OPERATION NEEDS DIAGNOSED. | DUSTINS | DUSTINS | | H07 | C | 8085389 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/19/2024 | PERFORMED EXTERNAL VISUAL INSPECTION -- / NO VISIBLE ISSUES / RBD NOTE: CHECK TOP DECK KEY SWITCH AT WITNESS TEST 5/2024 (Receipt #2043774) | DUSTINS | DUSTINS | | H02 | C | 8025659 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 03/12/2024 | ACCIDENT REPORT RECORDED (2 REPORTS) - SEE IMAGES | DUSTINS | DUSTINS | | HE16 | C | 8021856 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 02/19/2024 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 8026912 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 11/09/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | DUSTINS | DUSTINS | | HE16 | C | 7913412 |
CTY OF C/S - MUNICIPAL AIRPORT | H01 | C | 09/25/2023 | PERFORMED EXTERNAL VISUAL INSPECTION -- / RBD NOTE: CHECK TOP DECK KEY SWITCH AT WITNESS TEST 5/2024 (Receipt #1991532) | DUSTINS | DUSTINS | | H01 | C | 7866475 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 07/12/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7795517 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 05/31/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7760411 |
CTY OF C/S - MUNICIPAL AIRPORT | H07 | C | 05/30/2023 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS W/ SCHINDLER -- MINIMUM BRAKE TORQUE 81 FT/LBS, ACTUAL 115 FT/LBS -- / TOP DECK KEY SWITCH IS STILL BROKEN AND NEEDS REPLACED (FOURTH NOTICE) | DUSTINS | DUSTINS | | H07 | C | 7756793 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 03/31/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7706955 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/30/2023 | H02 -- PERFORMED EXTERNAL VISUAL INSPECTION (NO VISIBLE CODE ISSUES) | ROBERTV | ROBERTV | | H02 | C | 7703037 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 12/28/2022 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7621108 |
CTY OF C/S - MUNICIPAL AIRPORT | H01 | C | 09/27/2022 | TKE ESCALATOR WITH SCHINDLER SERVICE -- MCP LOCATED IN ELEVATOR MACHINE ROOM 3 --/ TOP KEY SWITCH IS STILL BROKEN AND SHALL BE REPLACED --/ SCHINDLER TO PROVIDE PPRBD WITH INFORMATION ON WHEN PARTS ARE TO ARRIVE AND BE REPLACED --/ NOTE: CHECK FOR RELAYS AND OIL AT INTERNAL EXAMINATION AT WITNESS TEST (Receipt #1902517) | MIKEM | MIKEM | | H01 | C | 7531157 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 06/23/2022 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7437971 |
CTY OF C/S - MUNICIPAL AIRPORT | H07 | C | 06/13/2022 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS-- MCP LOCATED IN ELEVATOR MACHINE ROOM 3--/ MINIMUM BRAKE TORQUE 81 FT/LBS ACTUAL 100 FT/LBS--/ TOP KEY SWITCH IS STILL BROKEN AND SHALL BE REPLACED (THIRD NOTICE)--/ RELAYS T 8.2 AND T 8.3 ARE STILL BROKEN/HANGING INSIDE THE CONTROLLER (THIRD NOTICE)--/ OIL IN TOP DECK NEEDS TO BE ADDRESSED--/ NOTE: COULD NOT IDENTIFY THE ELECTRO MECHANICAL BRAKING DEVICE AND A FOLLOW UP HAS BEEN SCHEDULED | MIKEM | MIKEM | | H07 | C | 7409124 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/03/2022 | TKE ESCALATOR - WITNESSED ANNUAL TESTING SCHEDULED FOR 5/2022 (CHECK PREVIOUS LISTED ITEMS) | ROBERTV | ROBERTV | | H02 | C | 7289625 |
CTY OF C/S - MUNICIPAL AIRPORT | H01 | C | 09/21/2021 | TKE ESCALATOR - NO DOCUMENTS ONSITE INDICATING REPAIRS FROM WITNESS TESTING HAVE BEEN ADDRESSED: ELECTRICAL FITTINGS AT CONTROLLER NEED ATTENTION. ELECTRICAL RELAYS INSIDE OF CONTROLLER NEED SECURED. TOP DECK KEY SWITCH SPINNING FREELY. ALSO, BOTTOM LEFT HANDRAIL NEWELL TRIM PIECE AT INLET NEEDS SECURED. OIL IN PIT NEEDS TO BE CLEANED UP AND SOURCE REPAIRED....... 60 DAYS TO ADDRESS
ESCALATOR MAINTENANCE CONTROL PROGRAM DOCUMENTS ARE SCATTERED AMONGST MULTIPLE ROOMS. THESE DOCUMENTS NEED TO BE GATHERED, SORTED, COMPILED AND IDENTIFIED FOR EACH ESCALATOR AND MADE AVAILABLE IN ONE LOCATION FOR INSPECTORS. BRAKE DATA TAG INFORMATION NEEDS TO BE RE-SCRIBED INTO PLATE....... 60 DAYS TO ADDRESS (Receipt #1808708) | ROBERTV | ROBERTV | | H01 | C | 7115283 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 05/25/2021 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS--/ MINIMUM BRAKE TORQUE 65 FT/LBS ACTUAL 100 FT/LBS--/ ELECTRICAL FITTINGS TO BE ADDRESSED AT CONTROLLER--/ ELECTRICAL RELAYS INSIDE OF CONTROLLER ARE NOT MOUNTED/SECURED PROPERLY--/ TOP DECK KEY SWITCH IS BROKEN AND SPINNING FREELY | MIKEM | MIKEM | | HE16 | C | 6980607 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/08/2021 | H02 -- ANNUAL SAFETY AND STEP INDEX TESTING DUE 4/2021 | ROBERTV | ROBERTV | | H02 | C | 6892011 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 04/15/2020 | ACCEPTANCE AND ANNUAL | ROBERTV | ROBERTV | | HE16 | C | 6732685 |