CTY OF C/S - MUNICIPAL AIRPORT | H07 | C | 05/15/2024 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS W/ SCHINDLER -- MINIMUM BRAKE TORQUE 81 FT/LBS, ACTUAL 115 FT/LBS -- / COMBPLATE WITH BROKEN TOOTH AT TOP NEEDS REPLACED | DUSTINS | DUSTINS | | H07 | C | 8085399 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/19/2024 | PERFORMED EXTERNAL VISUAL INSPECTION -- / COMBPLATE AT TOP HAS A BROKEN TOOTH / 60 DAYS TO ADDRESS (Receipt #2043771) | DUSTINS | DUSTINS | | H02 | C | 8025654 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 11/06/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | DUSTINS | DUSTINS | | HE16 | C | 7910501 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 09/27/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7873699 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 09/25/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7873690 |
CTY OF C/S - MUNICIPAL AIRPORT | H01 | C | 09/25/2023 | PERFORMED EXTERNAL VISUAL INSPECTION -- / COMBPLATE AT TOP HAS A BROKEN TOOTH / GAPS BETWEEN INNER DECK PANELS AND GLASS BALUSTRADES NEED ADDRESSED / GAPS BETWEEN INNER DECK REVEAL TRIM NEED ADDRESSED / 60 DAYS TO ADDRESS (Receipt #1991536) | DUSTINS | DUSTINS | | H01 | C | 7866487 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 08/24/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7836882 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 06/01/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7767145 |
CTY OF C/S - MUNICIPAL AIRPORT | H07 | C | 05/30/2023 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS W/ SCHINDLER -- MINIMUM BRAKE TORQUE 81 FT/LBS, ACTUAL 110 FT/LBS -- / COMBPLATE AT TOP MISSING TOOTH / GAPS BETWEEN INNER DECK PANELS AND GLASS BALUSTRADES NEED ADDRESSED / GAPS BETWEEN INNER DECK REVEAL TRIM NEED ADDRESSED | DUSTINS | DUSTINS | | H07 | C | 7756822 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 04/07/2023 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7710076 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/30/2023 | H02 -- PERFORMED EXTERNAL VISUAL INSPECTION. SEVERAL MISSING COMB TEETH AT BOTTOM END. SCREW STICKING OUT OF LEFT INNER DECK PANEL NEEDS TO BE ADDRESSED. GAPS BETWEEN INNER DECK PANELS AND GLASS BALUSTRADES NEED TO BE FIXED. GAPS BETWEEN INNER DECK REVEAL TRIM NEED TO BE FIXED. | ROBERTV | ROBERTV | | H02 | C | 7703076 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 12/29/2022 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7624713 |
CTY OF C/S - MUNICIPAL AIRPORT | H01 | C | 09/27/2022 | TKE ESCALATOR WITH SCHINDLER SERVICE -- MCP LOCATED IN ELEVATOR MACHINE ROOM 3 --/ SKIRT BRUSHES ARE DAMAGED AT THE LOWER DECK ON BOTH SIDES AND NEED TO BE REPAIRED/REPLACED --/ MISSING DECK BARRICADES IN BETWEEN ESCALATOR #1 AND #2 --/ SCHINDLER TO PROVIDE PPRBD WITH A TIME LINE FOR PARTS BEING DELIVERED AND FOR THE REPAIRS TO BE COMPLETED (Receipt #1902523) | MIKEM | MIKEM | | H01 | C | 7531175 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 09/13/2022 | ACCIDENT REPORT RECORDED - SEE IMAGES | ROBERTV | ROBERTV | | HE16 | C | 7515010 |
CTY OF C/S - MUNICIPAL AIRPORT | H07 | C | 06/13/2022 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS-- MCP LOCATED IN ELEVATOR MACHINE ROOM 3--/ MINIMUM BRAKE TORQUE 81 FT/LBS ACTUAL 114 FT/LBS (MAX)---/ SKIRT BRUSHES ARE DAMAGED AT THE LOWER DECK ON BOTH SIDES AND NEED TO BE REPAIRED/REPLACED--/ MISSING DECK BARRICADES IN BETWEEN ESCALATOR #1 AND #2--/ NOTE: COULD NOT IDENTIFY THE ELECTRO MECHANICAL BRAKING DEVICE AND A FOLLOW UP HAS BEEN SCHEDULED | MIKEM | MIKEM | | H07 | C | 7409081 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 04/15/2022 | ACCIDENT REPORT RECORDED (SEE IMAGES) | ROBERTV | ROBERTV | | HE16 | C | 7340330 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/03/2022 | TKE ESCALATOR - WITNESSED ANNUAL TESTING SCHEDULED FOR 5/2022 (CHECK PREVIOUS LISTED ITEMS) | ROBERTV | ROBERTV | | H02 | C | 7289613 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 11/02/2021 | 10/31/2021 ACCIDENT RECORDED | ROBERTV | ROBERTV | | HE16 | C | 7162247 |
CTY OF C/S - MUNICIPAL AIRPORT | H01 | C | 09/21/2021 | TKE ESCALATOR - LOWER RIGHT TRANSITION DECK PANEL HAS LOOSE AND STRIPPED SCREWS. ONE COMB PLATE ON THE BOTTOM END HAS BROKEN TEETH. LOWER LEFT TRANSITION DECK PANEL ALIGNMENT AT ADJACENT DECK PANEL IN THE RISE NEEDS ADDRESSED - (LOWER PANEL STICKS OUT 1/4" BEYOND ADJACENT PANEL). OIL IN PIT NEEDS TO BE CLEANED UP AND SOURCE REPAIRED....... 60 DAYS TO ADDRESS
ESCALATOR MAINTENANCE CONTROL PROGRAM DOCUMENTS ARE SCATTERED AMONGST MULTIPLE ROOMS. THESE DOCUMENTS NEED TO BE GATHERED, SORTED, COMPILED AND IDENTIFIED FOR EACH ESCALATOR AND MADE AVAILABLE IN ONE LOCATION FOR INSPECTORS. BRAKE DATA TAG INFORMATION NEEDS TO BE RE-SCRIBED INTO PLATE....... 60 DAYS TO ADDRESS (Receipt #1808710) | ROBERTV | ROBERTV | | H01 | C | 7115285 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 05/25/2021 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX TESTS--/ MINIMUM BRAKE TORQUE 65 FT/LBS ACTUAL 94 FT/LBS--/TOP DECK KEY SWITCH HAS A BROKEN KEY INSIDE OF IT--/ R.H. DECKING IS LACKING TAMPER PROOF SCREWS | MIKEM | MIKEM | | HE16 | C | 6980700 |
CTY OF C/S - MUNICIPAL AIRPORT | H02 | C | 03/08/2021 | H02 -- ANNUAL SAFETY AND STEP INDEX TESTING DUE 4/2021 | ROBERTV | ROBERTV | | H02 | C | 6892013 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 01/11/2021 | ACCIDENT RECORDED | ROBERTV | ROBERTV | | HE16 | C | 7017119 |
CTY OF C/S - MUNICIPAL AIRPORT | HE16 | C | 04/15/2020 | ACCEPTANCE AND ANNUAL | ROBERTV | ROBERTV | | HE16 | C | 6732718 |