HOMEOWNER | B= | C | 07/02/2021 | Rear deck - Finished basement - AC installed | TIMOTHYS | TIMOTHYS | | B= | C | 7024017 |
HOMEOWNER | BIN | C | 06/14/2021 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TIMOTHYS | TIMOTHYS | | BIN | C | 7000569 |
HOMEOWNER | BSP | P | 05/17/2021 | Rear deck stair landing piers ok | TIMOTHYS | TIMOTHYS | | BSP | P | 6971232 |
HOMEOWNER | BLA | C | 04/02/2021 | | TIMOTHYS | TIMOTHYS | | BLA | C | 6920568 |
HOMEOWNER | BIN | C | 04/02/2021 | | TIMOTHYS | TIMOTHYS | | BIN | C | 6920565 |
HOMEOWNER | BFR | C | 04/02/2021 | | TIMOTHYS | TIMOTHYS | | BFR | C | 6920560 |
HOMEOWNER | BIN | P | 04/02/2021 | Insulation installers certificate on file / Site inspection still needed | TIMOTHYS | TIMOTHYS | | BIN | P | 6919762 |
HOMEOWNER | BFR | P | 03/30/2021 | Provide engineered truss repair details for T04 at chord 13 and 11 / Missing H2.5s at T04E / Need to fireblock throughout / Missing ST22 straps (note 98) / Missing truss end bearing / Replce modified HTS20 at T01G / Strap top plate in mech room / Missing anchor within 12" of plate break basement bedroom closet / Tie bearing walls together each end rear basement wall / Training with Nathan R | TIMOTHYS | TIMOTHYS | | BFR | P | 6916023 |
HOMEOWNER | BSP | P | 03/25/2021 | FX Lumbergaurd installers certificate, AMM, test report on file / Engineered truss repair details on file / Beam pocket substitution letter on file | TIMOTHYS | TIMOTHYS | | BSP | P | 6910170 |
HOMEOWNER | BSP | P | 03/01/2021 | Front porch lid and posts ok / Rear deck lid and posts ok / Side awning frame ok | TIMOTHYS | TIMOTHYS | | BSP | P | 6884299 |
HOMEOWNER | BSP | R | 02/24/2021 | Front porch lid rafters are to attach directly to ridge beam with LRU28Z hangers - Make corrections or provide engineers letter approving as built conditions / Front porch posts ok / Rear deck lid trusses need (2) H2.5s at bearing wall each | TIMOTHYS | TIMOTHYS | | BSP | R | 6880434 |
HOMEOWNER | BSP | P | 01/11/2021 | center pier for middle of deck at rear of house okay | BOBF | BOBF | | BSP | P | 6831929 |
HOMEOWNER | BFD | C | 12/29/2020 | Drain around habitable to sump / Damp proofing OK | ADAML | ADAML | | BFD | C | 6821240 |
HOMEOWNER | BFN | C | 12/29/2020 | Foundation design on file 2000 psf / Engineer letter for footing/foundation on file - Ufer noted | ADAML | ADAML | | BFN | C | 6820650 |
HOMEOWNER | BFT | C | 12/29/2020 | Over excavation report on file 2000 psf / Drain around habitable / 1 1/2" float / 10% / Drain design on file | ADAML | ADAML | | BFT | C | 6820649 |
HOMEOWNER | BFT | P | 12/02/2020 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 6794608 |
HOMEOWNER | BFN | P | 12/02/2020 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 6794607 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | C | 07/01/2021 | | JOHNN | JOHNN | | E= | C | 7022549 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | R | 06/30/2021 | basement mech keyless fixtures: need guards where insulation is above and by steamer/ outside outlets need to be WR/ label both furnace disco's,on/off/ 30 amp a/c,ok | JOHNN | JOHNN | | E= | R | 7021211 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ES | C | 03/29/2021 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | JOHNN | JOHNN | | ES | C | 6913864 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ER | C | 03/29/2021 | notes: no specs for steamer, wiring not run, 1 floor heat in master, no jet tubs/ main panel: 3#8cu, rev ufer/ no mcc/ 100 amp sub basement,ok, no mcc, | JOHNN | JOHNN | | ER | C | 6913856 |
GENE'S HEATING AND AIR LLC | H= | C | 06/30/2021 | CORRECTION MADE, SEE IMAGES / | NICKE | NICKE | | H= | C | 7020043 |
GENE'S HEATING AND AIR LLC | H= | P | 06/17/2021 | INSTALL CONDENSATE DRAIN ON WATER HEATER VENT | NICKE | NICKE | | H= | P | 7005638 |
GENE'S HEATING AND AIR LLC | H= | P | 06/14/2021 | UNABLE TO VERIFY THAT WHOLE HOUSE VENTILATION SWITCH FUNCTIONS NO ELECTRICITY IN HOUSE. INSTALL WATER HEATER CONDENSATE DRAIN. HOOK GAS UP TO WATER HEATER. FURNACE CONDENSATE FOR MAIN FLOOR FURNACE NEEDS TO BE PROPERLY INSTALLED PER INSTALLATION INSTRUCTIONS PAGE 67. COMPLETE LOW VOLTAGE WIRING ON BASEMENT FURNACE. SECURE SUCTION LINE INSULATION TO COIL CABINET. WIRE OUTSIDE AIR DAMPER FOR BASEMENT FURNACE. WHOLE HOUSE VENTILATION BEING ACHIEVED WITH EXHAUST FAN LOCATED IN LAUNDRY ROOM / WHOLE HOUSE VENTILATION SWITCH LOCATED IN LAUNDRY ROOM / NOTE / FINISHED BASEMENT / HIGH/LOW GRILLES INTO MECHANICAL ROOM / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN x 2 / A/C COMPLETE ON MAIN FURNACE / DIRECT VENT FURNACE X 2 / | NICKE | NICKE | | H= | P | 7001926 |
GENE'S HEATING AND AIR LLC | HC | C | 03/19/2021 | RELEASE METER | MATTM | MATTM | | HC | C | 6905063 |
GENE'S HEATING AND AIR LLC | HRR | C | 03/19/2021 | VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / WHOLE HOUSE VENTILATION BEING ACHIEVED WITH EXHAUST FAN LOCATED IN LAUNDRY ROOM /
NOTE / FINISHED BASEMENT / 2X OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / 2X DIRECT VENT FURNACE / 1X A/C ROUGH, COIL AND LINESET / MEETS 50 TO 1 FOR WATER HEATER / | MATTM | MATTM | | HRR | C | 6905052 |
L & L GAS SHOP, LLC. | HI | C | 03/11/2021 | 10 LB TEST OK / 1 1/4 INCH MAIN / 2 FURNACE / 1 WATER HEATER / 1 RANGE / 1 FIREPLACE / 1 PATIO STUB / | MATTM | MATTM | | HI | C | 6896876 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 03/10/2021 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / | MATTM | MATTM | | HV | C | 6894975 |
FAIRWAY PLUMBING & HEATING, INC. | P= | C | 06/30/2021 | HAS PVB | LEE | LEE | | P= | C | 7021384 |
FAIRWAY PLUMBING & HEATING, INC. | PTO | C | 03/19/2021 | Note: vtr-2, aav at right master lav/left can be cwv, aav at powder lav, finished basement (1 finished bath-aav at lav, 1 unfinished bath), irrigation stub, bar sink is rough in only *At final, check steam unit for basement shower (instructions to be on-site), which is underneath the stairs | MALYNDA | MALYNDA | | PTO | C | 6904613 |
FAIRWAY PLUMBING & HEATING, INC. | PB | C | 01/08/2021 | | SAMH | SAMH | | PB | C | 6830857 |