THE COPESTONE COMPANY | B= | C | 02/26/2021 | All other required Final inspections are complete. (This is a computer generated result) | TIMOTHYS | TIMOTHYS | | B= | C | 6881798 |
THE COPESTONE COMPANY | B= | P | 02/01/2021 | Complete pending MEP finals. Additional Inspections Required (computer generated): INTERMOUNTAIN POWER SERVICES INC Electrical Final Inspection is not Completed yet, PEAK HEATING & AIR COND, INC. Mechanical Final Inspection is not Completed yet. | TIMOTHYS | TIMOTHYS | | B= | P | 6854303 |
THE COPESTONE COMPANY | B= | P | 01/29/2021 | Complete MEP final inspections / Missing sign at exit doors "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" 2015 IBC 1010.1.9.3 -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): HIGH COUNTRY PLUMBING LLC Plumbing Final Inspection is not Completed yet, INTERMOUNTAIN POWER SERVICES INC Electrical Final Inspection is not Completed yet, PEAK HEATING & AIR COND, INC. Mechanical Final Inspection is not Completed yet. | TIMOTHYS | TIMOTHYS | | B= | P | 6853905 |
THE COPESTONE COMPANY | BFR | P | 01/08/2021 | Attach plumbing to permit / Pending all other required inspections / Observed all light gauge metal framing / Reviewed accessible elements | ADAML | ADAML | | BFR | P | 6829955 |
INTERMOUNTAIN POWER SERVICES INC | E= | C | 02/26/2021 | Corrections made / Thank - You | BRETC | BRETC | | E= | C | 6881697 |
INTERMOUNTAIN POWER SERVICES INC | E= | P | 01/29/2021 | Splice drawings to show power to ejector pump in break room / Need handle tie for dishwasher and ejector pump / Send info on line volt switches used on low volt wiring / Rest - Ok / Splice required, please submit splice for changes in scope. If unfamiliar in submitting electronic splice, please click the following link: https://youtu.be/dG3kHpgDP0w / Pics ok, upload images with next inspection request. If you encounter problems uploading images, please contact IT at 799-2688 / | BRETC | BRETC | | E= | P | 6853151 |
STILSON ELECTRIC SYSTEMS, INC. | E= | C | 01/22/2021 | FIRE ALARM INSPECTION: 4 device relocate - Ok | BRETC | BRETC | | E= | C | 6845398 |
INTERMOUNTAIN POWER SERVICES INC | ER | C | 01/20/2021 | grid,ok | JOHNN | JOHNN | | ER | C | 6842744 |
INTERMOUNTAIN POWER SERVICES INC | ER | P | 01/19/2021 | ceiling,need 4 clip or 4 screw, need re inspect for ceiling/ | JOHNN | JOHNN | | ER | P | 6839858 |
INTERMOUNTAIN POWER SERVICES INC | ER | P | 01/08/2021 | All walls only - Ok | BRETC | BRETC | | ER | P | 6829655 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 02/26/2021 | ALL CORRECTIONS MADE NOTES: PLAN SPLICE AND TAB REPORT ARE COMPLETE | JERRYF | JERRYF | | H= | C | 6881797 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 01/21/2021 | PARTIAL PENDING THE FOLLOWING - ADD NEW FAN AT DATA ROOM TO PERMIT WORK SCOPE AND NEED PLAN SPLICE FOR SAME - THERMOSTATS - TAB REPORT NOTES: ALL SA / RA GRILLES AND CONNECTIONS ARE COMPLETE | JERRYF | JERRYF | | H= | P | 6844858 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | C | 12/30/2020 | PLUMBING CONTRACTOR MUST ATTACH TO PERMIT / ALL ABOVE CEILING DUCT ROUGH OK. OK TO INSULATE / | LIDO | LIDO | | HD | C | 6822814 |
HIGH COUNTRY PLUMBING LLC | P= | C | 01/29/2021 | PHOTO INSPECTED | LEE | LEE | | P= | C | 6854026 |
HIGH COUNTRY PLUMBING LLC | P= | P | 01/29/2021 | EJECTOR LACKING BALL VALVE DOWNSTREAM OF CHECK -- REST OK | LEE | LEE | | P= | P | 6854017 |
HIGH COUNTRY PLUMBING LLC | PTO | P | 01/14/2021 | TESTS OK -- STILL NEED REVISIONS (SEE PREVIOUS INSP) | LEE | LEE | | PTO | P | 6836622 |
HIGH COUNTRY PLUMBING LLC | PTO | P | 01/13/2021 | NEED PLANS REVISED TO SHOW EJECTOR PUMP / SIZING AND LOCATION FOR TIE IN -- ALSO NEED TO TEST DWV AND INSULATE DOMESTIC WATER | LEE | LEE | | PTO | P | 6835148 |
PEAK HEATING & AIR CONDITIONING, INC. | XMS | T | 02/18/2021 | PAID (REC#1752835): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: adjusted schedules | TCRIPPEN | TCRIPPEN | | XMS | T | 6874574 |
INTERMOUNTAIN POWER SERVICES INC | XES | T | 02/17/2021 | PAID (REC#1752750): PLAN SPLICE FEE: $50 by: SHELBY for Electrical: Add sink drain pump | SHELBY | SHELBY | | XES | T | 6872482 |
PEAK HEATING & AIR CONDITIONING, INC. | XMS | P | 01/20/2021 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Mechanical: New splice see sheet notes | TCRIPPEN | TCRIPPEN | | XMS | P | 6841862 |
PEAK HEATING & AIR CONDITIONING, INC. | XMS | P | 01/15/2021 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Mechanical: okay new splice:Added exhaust schedule, revised notes page | TCRIPPEN | TCRIPPEN | | XMS | P | 6837675 |
HIGH COUNTRY PLUMBING LLC | XPS | T | 01/15/2021 | PAID (REC#1743316): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Delta 2 revisions: 1 sheet provided, P1.0 adjusted plumbing plan and hex notes | SHANEN | SHANEN | | XPS | T | 6837297 |