SPRINGS REMODEL AND REPAIR LLC | B= | C | 02/10/2021 | All other required Final inspections are complete. (This is a computer generated result) | CHAD | CHAD | | B= | C | 6866437 |
SPRINGS REMODEL AND REPAIR LLC | B= | P | 02/03/2021 | Building final OK pending other finals /. Additional Inspections Required (computer generated): ELECTRICAL PROS OF COLORADO LLC Electrical Final Inspection is not Completed yet, J & J MECHANICAL, INC Plumbing Final Inspection is not Completed yet. | CHAD | CHAD | | B= | P | 6858315 |
SPRINGS REMODEL AND REPAIR LLC | BFR | P | 01/20/2021 | Complete Mech rough / Frame corrections ok | CHAD | CHAD | | BFR | P | 6842497 |
SPRINGS REMODEL AND REPAIR LLC | BFR | R | 01/13/2021 | Missing fireblocking through out / Need to attach mech permit / Reviewed Smoke and CO requirements / | CHAD | CHAD | | BFR | R | 6834671 |
ELECTRICAL PROS OF COLORADO LLC | E= | C | 02/04/2021 | | LOGANP | LOGANP | | E= | C | 6859741 |
ELECTRICAL PROS OF COLORADO LLC | E= | R | 02/03/2021 | open lamp in clothes closet, replace afci breaker will not trip with test button | BRET | BRET | | E= | R | 6858594 |
ELECTRICAL PROS OF COLORADO LLC | ER | C | 01/12/2021 | bedroom , bath , Discussed AFCI/GFCI/TR requirements | TOMC | TOMC | | ER | C | 6832682 |
POLAR BEAR MECHANICAL LTD | H= | C | 01/22/2021 | CHANGED BATH FAN TO 50 CFM , BATH FAN ,DUCTING AND TERMINATION OK. | TREVORH | TREVORH | | H= | C | 6846162 |
POLAR BEAR MECHANICAL LTD | HRR | P | 01/20/2021 | PER THE 2015 IRC TABLE M1506.2 BATH EXHAUST DUCTING IS UNDERSIZED AT THE CURRENT LENGTH FOR THE 80 CFM FAN. | TREVORH | TREVORH | | HRR | P | 6842500 |
J & J MECHANICAL, INC | P= | C | 02/10/2021 | slip joint overflow removed. | TAYLOR | TAYLOR | | P= | C | 6866436 |
J & J MECHANICAL, INC | P= | P | 02/05/2021 | loose shower arm, need access to slip joint overflow, set tub/ shower temp, rest ok. | TAYLOR | TAYLOR | | P= | P | 6861548 |
J & J MECHANICAL, INC | PTO | C | 01/12/2021 | need mechanical permit attached. | TAYLOR | TAYLOR | | PTO | C | 6833189 |
J & J MECHANICAL, INC | PTO | P | 01/11/2021 | support hot water line above tub, anchor closet flange, missing nail protection at tub/ shower valve, rest ok, aav at lav and check access to slip joint overflow at tub by final. | TAYLOR | TAYLOR | | PTO | P | 6831983 |
J & J MECHANICAL, INC | PB | C | 01/11/2021 | toilet and lav drains ok. | TAYLOR | TAYLOR | | PB | C | 6831972 |