SPRINGS HOME IMPROVEMENT CO. | B= | C | 03/01/2021 | All other required Final inspections are complete. (This is a computer generated result) | ADAML | ADAML | | B= | C | 6883482 |
SPRINGS HOME IMPROVEMENT CO. | B= | P | 02/26/2021 | Building final complete pending electrical. Additional Inspections Required (computer generated): LINHARDT ELECTRIC, LLC Electrical Final Inspection is not Completed yet. | ADAML | ADAML | | B= | P | 6882921 |
SPRINGS HOME IMPROVEMENT CO. | BFR | P | 02/03/2021 | Still need to attach mechanical to permit and complete all MEP rough inspections / Frame okay pending other inspections | JEREMYD | JEREMYD | | BFR | P | 6857643 |
SPRINGS HOME IMPROVEMENT CO. | BFR | P | 01/29/2021 | Need to seal penetrations through top plate - ok to verify with photos / Rest of frame ok pending other inspections / Reviewed Smoke and CO requirements. UPDATE: 02/03 by JeremyD -- Upon Further Review, need to attach mechanical permit and complete all mechanical inspections. | JEREMYD | JEREMYD | | BFR | P | 6853699 |
LINHARDT ELECTRIC, LLC | E= | C | 03/01/2021 | | CRAIGS | CRAIGS | | E= | C | 6883481 |
LINHARDT ELECTRIC, LLC | E= | R | 02/26/2021 | 20 amp bathroom circuit can not leave the bathroom --- remove closet light off the bathroom circuit | CRAIGS | CRAIGS | | E= | R | 6882194 |
LINHARDT ELECTRIC, LLC | ER | R | 01/29/2021 | Rough ok / Panel not labeled -- Need to identify ckts by final / Need to verify at final that 20 amp ckt in bath is dedicated to recpts / | ROB | ROB | | ER | R | 6853205 |
POPES PLUMBING HEATING & AC INC. | H= | C | 02/12/2021 | ok. | PAULO | PAULO | | H= | C | 6869626 |
POPES PLUMBING HEATING & AC INC. | HRR | C | 02/12/2021 | bath fan/exhaust duct with termination and relocated return air duct ok. | PAULO | PAULO | | HRR | C | 6869621 |
POPES PLUMBING HEATING & AC INC. | P= | C | 02/23/2021 | | LEE | LEE | | P= | C | 6877804 |
POPES PLUMBING HEATING & AC INC. | PTO | C | 02/01/2021 | CONTRACTOR FOUND LISTING IN LITERATURE PROVIDED H/O -- VERIFIED | LEE | LEE | | PTO | C | 6855678 |
POPES PLUMBING HEATING & AC INC. | PTO | P | 02/01/2021 | ALL OK PENDING A MIN. 3RD PARTY LISTING FOR SHOWER TOWER | LEE | LEE | | PTO | P | 6855117 |
POPES PLUMBING HEATING & AC INC. | PTO | R | 01/29/2021 | missing nail protection throughout, install and anchor closet flange, low test DWV, install shower valve, re- grade 2 inch drain for shower/ lavs and right master trap arm, need mechanical permit attached, re- inspect all. | TAYLOR | TAYLOR | | PTO | R | 6852832 |
POPES PLUMBING HEATING & AC INC. | PTO | P | 01/28/2021 | need to attach to building permit N27895, need to test thru tub and shower p-traps, need to verify tempering at shower valve and tub valves, need to verify tub trap will not be in cantilever or it will need freeze protection, re-inspect all | JOSEPHD | JOSEPHD | | PTO | P | 6851130 |