HOMEOWNER | B= | C | 02/08/2022 | Finished basement -- Front deck no stairs | CHAD | CHAD | | B= | C | 7263594 |
HOMEOWNER | BIN | C | 01/24/2022 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | CHAD | CHAD | | BIN | C | 7247407 |
HOMEOWNER | BIN | C | 01/18/2022 | | CHAD | CHAD | | BIN | C | 7240676 |
HOMEOWNER | BSP | P | 01/18/2022 | Inspection notes for deck piers-- Deck piers previously inspected with previous BSP dated 8-6-21 | CHAD | CHAD | | BSP | P | 7240672 |
HOMEOWNER | BIN | P | 12/08/2021 | ICF basement walls | CHAD | CHAD | | BIN | P | 7202540 |
HOMEOWNER | BFD | C | 12/08/2021 | Sign off -- Paperwork received | CHAD | CHAD | | BFD | C | 7202531 |
HOMEOWNER | BFR | P | 12/08/2021 | Basement framing ok -- Deck framing ok -- Garage framing ok -- Complete other roughs -- Discussed air leakage need by final -- Discussed final inspection process with homeowner | CHAD | CHAD | | BFR | P | 7202528 |
HOMEOWNER | BSP | P | 08/06/2021 | Deck piers per plan / Rear stair piers per plan | CHAD | CHAD | | BSP | P | 7063281 |
HOMEOWNER | BVM | C | 02/24/2021 | Placed state insignia 2020-7940 electrical box / Note - Need to complete Drain inspection | CHAD | CHAD | | BVM | C | 6879597 |
HOMEOWNER | BTD | C | 02/24/2021 | BTD ok / 20-M34296 / | CHAD | CHAD | | BTD | C | 6879582 |
HOMEOWNER | BFN | C | 02/24/2021 | All paperwork on file | CHAD | CHAD | | BFN | C | 6879473 |
HOMEOWNER | BFT | C | 02/24/2021 | Open hole on file 2000 psf -- Useable drain -- 10% | CHAD | CHAD | | BFT | C | 6879010 |
HOMEOWNER | BTD | L | 02/23/2021 | Cancelled per homeowner / House locked / No inspection performed | CHAD | CHAD | | BTD | L | 6878032 |
HOMEOWNER | BFN | P | 02/23/2021 | Complete BFT /Foundation design in plan set 1500 psf / Foundation observation on file - Ufer noted | CHAD | CHAD | | BFN | P | 6877486 |
HOMEOWNER | BFT | P | 02/23/2021 | Provide open hole and soils report / Footer observation on file | CHAD | CHAD | | BFT | P | 6877482 |
HOMEOWNER | BFN | P | 01/15/2021 | Authorized 3rd party engineer inspection with all observation paperwork to follow | JEREMYA | JEREMYA | | BFN | P | 6838221 |
HOMEOWNER | BFT | P | 01/15/2021 | Authorized 3rd party engineer inspection with all observation paperwork to follow | JEREMYA | JEREMYA | | BFT | P | 6838157 |
HOMEOWNER | BFN | L | 01/15/2021 | Cancelled via phone call per homeowner (Nathan) | CHAD | CHAD | | BFN | L | 6837548 |
HOMEOWNER | BFT | L | 01/15/2021 | Cancelled via phone call per homeowner (Nathan) | CHAD | CHAD | | BFT | L | 6837547 |
METHOD ELECTRIC LLC | E= | C | 01/21/2022 | received pictures --- thank you | TOMC | TOMC | | E= | C | 7246500 |
METHOD ELECTRIC LLC | E= | R | 01/12/2022 | finish labeling panel , protect wire in garage ran horizontal below 6'6" | TOMC | TOMC | | E= | R | 7236526 |
METHOD ELECTRIC LLC | ES | C | 01/12/2022 | Residential Underground: 200-amp 3-wire service upgrade, no action required by utility. / | TOMC | TOMC | | ES | C | 7236515 |
METHOD ELECTRIC LLC | ER | C | 11/03/2021 | 5 - # 10 , 1 - 4/0 urd , finished basement | TOMC | TOMC | | ER | C | 7164080 |
HOMEOWNER | EUG | C | 07/09/2021 | 10/3 uf to well | TOMC | TOMC | | EUG | C | 7030553 |
METHOD ELECTRIC LLC | EUG | C | 03/04/2021 | 250 urd / #2 grd | TOMC | TOMC | | EUG | C | 6888192 |
METHOD ELECTRIC LLC | ESL | C | 03/01/2021 | 1 - pvc floor box | TOMC | TOMC | | ESL | C | 6883457 |
HOMEOWNER | H= | C | 02/02/2022 | RECEIVED IMAGES OF CORRECTIONS FROM HOMEOWNER, SEE IMAGES / DOORWAY AND HEADER REMOVED FROM BATH 2 WATER CLOSET; NO SEPARATION FROM SHOWER ROOM / CFM FOR EXHAUST FAN AT BATH 2 MEETS REQUIREMENT FOR THIS INSTALLATION / WHOLE HOUSE VENTILATION SWITCH LOCATED IN BATH 1 / | WHITNEYH | WHITNEYH | | H= | C | 7257779 |
HOMEOWNER | H= | P | 01/28/2022 | BATH 2 LACKS EXHAUST FAN IN SHOWER ROOM DUE TO DOOR SEPARATING WATER CLOSET AND SHOWER ROOM / MISSING LABELED WHOLE HOUSE VENTILATION SWITCH AT BATH 1 / Whole house ventilation being achieved through exhaust fan located in bathroom / Label whole house ventilation switch / NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE / DIRECT VENT BOILER WITH SIDE-ARM / NO A/C / | WHITNEYH | WHITNEYH | | H= | P | 7254195 |
HOMEOWNER | HRR | C | 11/09/2021 | Whole house ventilation being achieved through exhaust fan located in basement bathroom. / Verify whole house ventilation switch location at final / NOTE / FINISHED BASEMENT / MANUFACTURED HOME DIRECT VENT FURNACE / DIRECT VENT COMBI BOILER / NO A/C / | WHITNEYH | WHITNEYH | | HRR | C | 7170779 |
TED'S PLUMBING AND HYDRONICS LLC | HSP | P | 11/08/2021 | Received image of boiler exhaust thimble, see images / Inspection type changed to HSP, this permit is a 101, unable to complete final for this permit until all mechanical work is completed / Still need to verify corrections to HRR for homeowner listed on inspection dated 10/1/21 / | WHITNEYH | WHITNEYH | | HSP | P | 7168268 |
TED'S PLUMBING AND HYDRONICS LLC | HRR | P | 10/05/2021 | STILL MISSING GALVANIZED SHEET METAL WALL THIMBLE FOR BOILER EXHAUST HORIZONTAL SIDE-WALL TERMINATION PER PAGE 16 SEC 2.2.2 ITEM 2 / | WHITNEYH | WHITNEYH | | HRR | P | 7130726 |
HOMEOWNER | HRR | P | 10/01/2021 | BOTH BATHROOM EXHAUST DUCTS ARE UNDERSIZED AT 4 INCH FOR 110 CFMS / HOMEOWNER PROVIDED DRYER SPEC SHEET DUE TO EXCESS OF 35' OF DUCT INSTALLED FOR BASEMENT DRYER EXHAUST, WILL NEED SPEC SHEET AT FINAL AND DRYER DUCT NOTIFICATION LABEL IN PLACE / COMPLETE FURNACE TERMINATION AT ROOF-TOP PER MANUFACTURERS REQUIREMENTS / COMPLETE SOFFIT IN BASEMENT MASTER BATH TO VERIFY PROTECTION OF DRYER DUCT THROUGHOUT PASSAGE / Whole house ventilation being achieved through exhaust fan located in bathroom. / Verify whole house ventilation switch location at final / NOTE / FINISHED BASEMENT / DIRECT VENT COMBI BOILER / DIRECT VENT FURNACE / NO A/C / | RICHG | RICHG | | HRR | P | 7127861 |
TED'S PLUMBING AND HYDRONICS LLC | HWP | C | 10/01/2021 | NOTE/ 50 LB TEST OK FOR UPPER LEVEL STAPLE UP. | RICHG | RICHG | | HWP | C | 7127722 |
GLASER ENERGY GROUP INC. | HSP | P | 09/22/2021 | PER COMMUNICATION FROM HOMEOWNER, UNDERGROUND TANK WILL NOT BE INSTALLED / ABOVE GROUND TANK TO BE UTILIZED / BY FINAL, WILL NEED TO SEE 2ND STAGE REGULATOR IN PLACE AT EXTERIOR OF HOME AND FINAL CONNECTION TO PROPANE TANK / | WHITNEYH | WHITNEYH | | HSP | P | 7116300 |
TED'S PLUMBING AND HYDRONICS LLC | HI | C | 09/22/2021 | | WHITNEYH | WHITNEYH | | HI | C | 7116292 |
TED'S PLUMBING AND HYDRONICS LLC | HRR | P | 09/08/2021 | CHANGED TO HRR / NO FIREPLACES INSTALLED ON-SITE / HV INSPECTION IN RESIDENTIAL APPLICATIONS IS RESERVED ONLY FOR FIRE-PLACE INSPECTIONS / BOILER VENTING IN PLACE, COMPLETED INSPECTION OF BOILER VENTING ONLY- REST OF HRR NOT READY FOR INSPECTION / MISSING WALL THIMBLES AT HORIZONTAL VENT TERMINATION PER MANUFACTURERS REQUIREMENTS / - REST OF VENT INSTALLATION OK / | WHITNEYH | WHITNEYH | | HRR | P | 7100198 |
TED'S PLUMBING AND HYDRONICS LLC | HI | P | 09/08/2021 | ALL GAS PIPE TO BE SUPPORTED TO REQUIREMENTS IN 2015 IRC TABLE 2424.1 / GAS PIPE MAY NOT BE SUPPORTED ON PLUMBING FIXTURES OR SOLELY ON STYROFOAM INSULATION / RANGE OUTLET - 2 INCHES UNTHREADED GAS PIPE REQUIRED AT PENETRATION THROUGH FLOOR PER 2015 IRC SEC G2415.16 / DISCUSSED OUTLETS IN MAIN LEVEL LIVING ROOM AND BASEMENT FAMILY ROOM WITH HOMEOWNER - OUTLETS ARE FOR FUTURE FIREPLACES TO BE INSTALLED AND INSPECTED UNDER SEPARATE PERMIT / NOTE / PROPANE SYSTEM / 10 LB TEST OK / 1 1/4 INCH MAIN / 1 BOILER / 1 FURNACE / 1 RANGE / 1 DRYER / 2 FUTURE FIREPLACE OUTLETS BOTH 3/4 INCH COMBINED TOTAL NOT TO EXCEED 274K IF BBQ OUTLETS DO NOT EXCEED 40K EACH / 2 BBQ OUTLETS/ 1 FUTURE 1/2 INCH OUTLET CAPPED IN MECHANICAL ROOM FOR FUTURE USE / WILL NEED TO SEE 2ND STAGE REGULATOR IN PLACE AND VERIFY CONNECTION BETWEEN UNDERGROUND RISER AND REGULATOR FOR MAIN AT FINAL / | WHITNEYH | WHITNEYH | | HI | P | 7100184 |
GLASER ENERGY GROUP INC. | HO | C | 05/05/2021 | NOTE / 10 LB TEST OK / 1/2 INCH POLY WITH TRACER 60' FROM ABOVE GROUND PROPANE TANK TO RISER AT HOUSE / TRENCH DEPTH VERIFIED, OK TO COVER / WILL NEED TO SEE SECOND STAGE REGULATOR IN PLACE AT HOME BY FINAL / STILL NEED INSIDE GAS LINE INSPECTION WHEN READY / | WHITNEYH | WHITNEYH | | HO | C | 6957643 |
GLASER ENERGY GROUP INC. | HO | P | 04/14/2021 | Update 4/19 WH: Permitting poly line with tracer up to 4' of coil location in trench to be covered, will need inspection to verify gas line connection to underground tank and trench for that portion of gas line once tank is in place-- discussed with Dave Glaser on 4/19/21 / Update 4/16 WH:-- Spoke with Dave Glasier, underground tank on order- Outdoor underground line sized to accommodate burial of underground tank- pressure test on installed line verified-- / UPDATE 4/14 WH: Following review, coil of poly within trench will not be permitted, gas line to be cut to appropriate size and new pressure test to be provided once correction to install has occurred / Contractor communicated possible movement of propane tank at exterior to full re-inspect of outdoor line to be completed at next inspection /FURTHER RESEARCH ON POLY COIL WITHIN TRENCH PRIOR TO RISER FOR PROPANE TANK / WILL UPDATE NOTES ASAP / NOTE / 10 LB TEST OK ON 55' OF POLY WITH TRACER FROM RISER AT HOME TO PROPANE TANK DO NOT COVER UNTIL NOTES UPDATED / | WHITNEYH | WHITNEYH | | HO | P | 6933115 |
HOMEOWNER | HWP | P | 03/03/2021 | 60 LB TEST OK FOR TWO RADIANT ZONES IN BASEMENT OK TO COVER UP, STILL NEED TO VERIFY ZONES FOR GARAGE FLOOR AT NEXT INSPECTION REQUEST. | TREVORH | TREVORH | | HWP | P | 6886587 |
HOMEOWNER | P= | C | 02/07/2022 | NOTE/ No potable water certificate needed on a cistern | CODYP | CODYP | | P= | C | 7260959 |
HOMEOWNER | PWO | C | 02/07/2022 | NOTE/ Cistern only, no well at this time | CODYP | CODYP | | PWO | C | 7260956 |
TED'S PLUMBING AND HYDRONICS LLC | PTO | C | 01/28/2022 | | CODYP | CODYP | | PTO | C | 7253592 |
HOMEOWNER | P= | P | 01/28/2022 | PROVIDE CERTIFICATE OF POTABLE WATER, COMPLETE PWO INSPECTION, NOTE/ Finished basement/ No Irrigation/ 1-Future bar sink | CODYP | CODYP | | P= | P | 7253576 |
TED'S PLUMBING AND HYDRONICS LLC | PTO | P | 09/08/2021 | MISSING NAIL PROTECTION @ WATER LINES TO MAIN LEVEL MASTER SHOWER VALVE, OK TO ATTACH PHOTO AT NEXT INSPECTION REQUEST, NOTE/ Potable water certificate by final/ AAV @ bar sink/ AAV between master lavs/ AAV @ wall behind master toilet/ AAV @ hallway lav/ 1-VTR | CODYP | CODYP | | PTO | P | 7099557 |
HOMEOWNER | PWO | P | 07/06/2021 | water service ok from house to pump pit, need to complete well to pump pit, note: need certificate of potable water by final. | TAYLOR | TAYLOR | | PWO | P | 7026072 |
TED'S PLUMBING AND HYDRONICS LLC | PB | C | 02/08/2021 | H2O under footer. | TAYLOR | TAYLOR | | PB | C | 6863524 |
TED'S PLUMBING AND HYDRONICS LLC | PB | P | 02/05/2021 | low test, need to vent toilets ( can not have 3 inch waste stacks upstream of wet vents ), rest ok. | TAYLOR | TAYLOR | | PB | P | 6861977 |