LAURIA BUILDERS & LAND, LLC. | B= | C | 09/14/2021 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | TRENTP | TRENTP | | B= | C | 7105619 |
LAURIA BUILDERS & LAND, LLC. | BSP | P | 09/14/2021 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | TRENTP | TRENTP | | BSP | P | 7105609 |
LAURIA BUILDERS & LAND, LLC. | B= | P | 09/13/2021 | Still need to provide test report and installers certificate for product used as fire protection of floors / Rest of items corrected, photos on file -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 7104170 |
LAURIA BUILDERS & LAND, LLC. | B= | R | 09/08/2021 | Provide product test report and installers certificate for material used in fire protection of floors per IRC 302.13 EX #4 / Missing code compliant address numbers on house / Missing egress ladder in basement / Unfinished basement, no deck, no AC. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | R | 7100521 |
LAURIA BUILDERS & LAND, LLC. | BSP | P | 09/08/2021 | Changed to BSP / Still need to provide test report and proper installers certificate per test report for product used as fire protection of floors / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TRENTP | TRENTP | | BSP | P | 7099191 |
LAURIA BUILDERS & LAND, LLC. | BLA | C | 07/06/2021 | | TRENTP | TRENTP | | BLA | C | 7025900 |
LAURIA BUILDERS & LAND, LLC. | BIN | C | 06/30/2021 | Will inspect attic insulation at final, need air leakage test results by final / Need test report and installers cert for product used for fire protection of floor by final | TRENTP | TRENTP | | BIN | C | 7020682 |
LAURIA BUILDERS & LAND, LLC. | BFR | C | 06/30/2021 | Previous items corrected | TRENTP | TRENTP | | BFR | C | 7020677 |
LAURIA BUILDERS & LAND, LLC. | BFR | R | 06/28/2021 | Still need to correct front porch post caps at center post / Missing pipe jacks for dry in / Incorrect fasteners used in HUS hanger at A trusses / Provide Test report for materials used for fire protection of floor per IRC 302.13 EX #4 / Unfinished basement, no deck | TRENTP | TRENTP | | BFR | R | 7017890 |
LAURIA BUILDERS & LAND, LLC. | BSP | R | 06/07/2021 | Front porch post caps are to be used in pairs per manufacturer, will accept photos of corrections uploaded to inspection request / Rest of front porch frame and A straps/holddowns okay / Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | TRENTP | TRENTP | | BSP | R | 6992706 |
LAURIA BUILDERS & LAND, LLC. | BFN | C | 05/18/2021 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 6971571 |
LAURIA BUILDERS & LAND, LLC. | BFT | C | 05/18/2021 | open hole on file -- 2000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | TRENTP | TRENTP | | BFT | C | 6971565 |
LAURIA BUILDERS & LAND, LLC. | BFD | C | 05/17/2021 | Drain around usable to sump pit, dampproofing okay / Note: Need to complete BFT and BFN | TRENTP | TRENTP | | BFD | C | 6971074 |
LAURIA BUILDERS & LAND, LLC. | BFD | P | 05/17/2021 | Upload of soils report / Pending field inspection for drain | TRENTP | TRENTP | | BFD | P | 6970172 |
LAURIA BUILDERS & LAND, LLC. | BFN | P | 05/17/2021 | Need to complete BFT and provide foundation observation / Foundation design on file, need to verify bearing capacity w/ open hole | TRENTP | TRENTP | | BFN | P | 6970171 |
LAURIA BUILDERS & LAND, LLC. | BFT | P | 05/17/2021 | Need to provide open hole and footing observation / Soils report on file | TRENTP | TRENTP | | BFT | P | 6970168 |
LONGHORN ELECTRIC, INC. | E= | C | 08/26/2021 | E= OK ----- NO A/C ----- | GREGM | GREGM | | E= | C | 7086313 |
LONGHORN ELECTRIC, INC. | ES | C | 06/22/2021 | Residential Underground: 125-amp 3 Wire New Residence ok to set meter / | AARONR | AARONR | | ES | C | 7011652 |
LONGHORN ELECTRIC, INC. | ER | C | 06/22/2021 | IR ufer --- 1x #10 cu --- no mcc --- no vac --- 20 amp fridge --- unfinished basement. | AARONR | AARONR | | ER | C | 7011649 |
LONGHORN ELECTRIC, INC. | EUG | C | 06/17/2021 | 1/0 urd | TOMC | TOMC | | EUG | C | 7006827 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 08/27/2021 | WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATED IN THE MECHANICAL ROOM / NOTE / UNFINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / A/C , COIL AND LINE SET / | TREVORH | TREVORH | | H= | C | 7088091 |
MJB PLUMBING AND HEATING, INC | HC | C | 06/24/2021 | ADDING 230 K TO CURRENT DEMAND | TREVORH | TREVORH | | HC | C | 7014781 |
MJB PLUMBING AND HEATING, INC | HI | C | 06/24/2021 | 10 LB TEST OK / 1 1/2 INCH MAIN / 1 FIREPLACE / 1 FURNACE / 1 RANGE / 1 WATER HEATER / | TREVORH | TREVORH | | HI | C | 7014779 |
MJB PLUMBING AND HEATING, INC | HO | C | 06/24/2021 | 10 LB TEST OK FOR 478' OF 2'' POLY WITH TRACER WIRE FROM METER TO RISER AT GUEST HOUSE. OK TO BURY LINE. AT FINAL VERIFY CONNECTION AT METER. | TREVORH | TREVORH | | HO | C | 7014770 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 06/24/2021 | WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / UNFINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / A/C ROUGH, COIL AND LINESET / | TREVORH | TREVORH | | HRR | C | 7014764 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 06/23/2021 | MISSING EXHAUST DUCTING FOR MASTER BATH, NEED TO CAP B-VENT IF WATER HEATER IS NOT INSTALLED . WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / UNFINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / A/C ROUGH, COIL AND LINESET / | TREVORH | TREVORH | | HRR | P | 7012932 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 06/09/2021 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / | TREVORH | TREVORH | | HV | C | 6996147 |
MJB PLUMBING AND HEATING, INC | P= | C | 08/27/2021 | note: no irrigation | JOSEPHD | JOSEPHD | | P= | C | 7088106 |
MJB PLUMBING AND HEATING, INC | PTO | C | 06/24/2021 | note: unfinished basement, at final check water heater and that t&p is run to approved location, check for backwater at KC trap in basement, check water main connection, vtr 3 | JOSEPHD | JOSEPHD | | PTO | C | 7014363 |
HOMEOWNER | PWO | C | 05/21/2021 | note: pre-existing well, potable water certification on permit K66662 | JOSEPHD | JOSEPHD | | PWO | C | 6977066 |