WELLS & WEST GENERAL CONTRACTORS, INC. | B= | C | 05/12/2021 | All other required Final inspections are complete. (This is a computer generated result) | JEREMYA | JEREMYA | | B= | C | 6966035 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 05/11/2021 | Building final complete. Additional Inspections Required (computer generated): PEAK HEATING & AIR COND, INC. Mechanical Final Inspection is not Completed yet. | JEREMYA | JEREMYA | | B= | P | 6964702 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 02/16/2021 | pending other required inspections / interior light gauge steel framing OK / reviewed accessible elements with site rep | LONNYS | LONNYS | | BFR | P | 6871675 |
PROCOM ELECTRICAL SERVICES, INC. | E= | C | 04/23/2021 | Corrections made / Upload added for sump pump ---- spliced / Thank - You | BRETC | BRETC | | E= | C | 6944472 |
PROCOM ELECTRICAL SERVICES, INC. | E= | P | 04/19/2021 | Need to bond/ground to each VAV disconnect (20 amp fused) /------------ Sump Pump will need to splice to drawings /--------------- Rest - Ok / --------------Splice required, please submit splice for changes in scope. If unfamiliar in submitting electronic splice, please click the following link: https://youtu.be/dG3kHpgDP0w / | BRETC | BRETC | | E= | P | 6938451 |
PROCOM ELECTRICAL SERVICES, INC. | ER | C | 04/19/2021 | Need to bond/ground to each VAV disconnect (20 amp fused) /------------ Sump Pump will need to splice to drawings /--------------- Rest - Ok / --------------Splice required, please submit splice for changes in scope. If unfamiliar in submitting electronic splice, please click the following link: https://youtu.be/dG3kHpgDP0w / | BRETC | BRETC | | ER | C | 6938433 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 04/05/2021 | 2 - VAV's will need OCP at units - Max 20 amps / 12-20a #10 x2 --- 30 amp brkr feed 480v 3ph | BRETC | BRETC | | ER | P | 6921814 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 03/30/2021 | Leave tile out around 2 VAV's | BRETC | BRETC | | ER | P | 6915595 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 03/29/2021 | Need to see 2 VAV's / Ceiling rough ok, FA not complete ---------do not close ceiling-------------- / | BRETC | BRETC | | ER | P | 6914703 |
PROCOM ELECTRICAL SERVICES, INC. | ESL | C | 03/17/2021 | Uploaded pics --------- 1 - Floor box with 3/4" PVC - Ok | BRETC | BRETC | | ESL | C | 6901155 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 03/03/2021 | Panel R1C wall - Ok | BRETC | BRETC | | ER | P | 6886379 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 02/11/2021 | All walls - Ok -------------------------- Except for Relocated R1C Panel location and floor box | BRETC | BRETC | | ER | P | 6868420 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 05/12/2021 | MECHANICAL FINAL COMPLETE./ | LIDO | LIDO | | H= | C | 6966034 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 05/05/2021 | TEST AND BALANCE REPORT RECEIVED. SEE IMAGES. FINAL PENDING : TF-1 MISSING THERMOSTAT / LABEL ALL THERMOSTATS / | LIDO | LIDO | | H= | P | 6957558 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 04/16/2021 | FINAL PENDING : TF-1 MISSING THERMOSTAT / LABEL ALL THERMOSTATS / NEED TEST AND BALANCE REPORT / | LIDO | LIDO | | H= | P | 6937511 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 03/31/2021 | ABOVE CEILING ROUGH : NEED TF-1 FAN AND DUCT INSTALLED, ALL RETURN AIR GRILL ,THERMOSTATS AND TEST AND BALANCE REPORT / ALL VAV'S , ALL SUPPLY DUCT ROUGH, SUPPLY FLEX DUCT AND GRILLS OK / | LIDO | LIDO | | HD | P | 6917343 |
FRONTIER MECHANICAL SYSTEMS INC | P= | C | 04/30/2021 | | LEE | LEE | | P= | C | 6953196 |
FRONTIER MECHANICAL SYSTEMS INC | P= | P | 04/28/2021 | STILL MISSING A HAMMER ARRESTOR AT THE DISHWASHER -- HIGH LOOP NOT HIGH AS POSSIBLE (NEEDS TO TOUCH BOTTOM OF COUNTER TOP) | LEE | LEE | | P= | P | 6950518 |
FRONTIER MECHANICAL SYSTEMS INC | P= | P | 04/20/2021 | NEED FULL FLOW GATE VALVE UPSTREAM OF CHECK AT EJECTOR -- INSTALL HAMMER ARRESTORS AT DISHWASHER AND ICE MAKER -- HIGH LOOP APPROX. 6" TOO LOW -- NEED PLANS SPLICE TO REFLECT EJECTOR AT BREAK SINK | LEE | LEE | | P= | P | 6939854 |
FRONTIER MECHANICAL SYSTEMS INC | PTO | P | 02/16/2021 | CHECKING ON SPLICE -- THERE IS NOT A SPLICE FOR THE EJECTOR PIPING / TIE IN AT THIS TIME -- TESTS OK WHEN APPROVED | LEE | LEE | | PTO | P | 6870728 |
PROCOM ELECTRICAL SERVICES, INC. | XES | P | 03/18/2021 | PLAN SPLICE: (No Fee) by: BERTHA for Electrical: Added sump pump | BERTHA | BERTHA | | XES | P | 6903786 |
FRONTIER MECHANICAL SYSTEMS INC | XPS | T | 03/16/2021 | PAID (REC#1758408): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Delta 3 revisions: 01/P.2 adjusted waste & vent isometric, suite 125 plumbing plan and fixture schedule | SHANEN | SHANEN | | XPS | T | 6899589 |